RICHARD A. KYLE, District Judge.
This case involves the failure of electrical meters sold by Plaintiff Cannon Technologies, Inc. ("Cannon"), which incorporated technology from Defendant/Third-Party Plaintiff Sensus Metering Systems, Inc. ("Sensus") and Third-Party Defendant Vishay Intertechnology, Inc. ("Vishay"). Cannon sued Sensus, asserting claims sounding in breach of warranty and fraud, and Sensus, in turn, brought similar third-party claims against Vishay. Sensus now moves for summary judgment on Cannon's claims, while Vishay moves for summary judgment on Sensus's third-party claims. For the reasons set forth below, each Motion will be granted in part and denied in part.
The Court recites below the key facts precipitating the present dispute. A full understanding of the parties' claims— about which the Court has received nearly 200 pages of briefs—necessitates the use of complex technical terms and a rudimentary explanation of certain components used in electrical circuitry. From the "satellite view," however, this case is relatively straightforward: (1) Cannon purchased a product from Sensus that it claims was defective; (2) Sensus purchased a component used in that product from Vishay, which component Sensus claims was defective; and (3) Vishay claims that the component was not defective and that Sensus misused it, which is what caused the product to fail. The Court provides this simplistic overview in the hope of providing some context for the more detailed explanation that follows.
Except where indicated below, the relevant facts are not in dispute.
Most persons are familiar with the electromechanical meters
Needless to say, reading electromechanical meters is an expensive and labor-intensive task. Moreover, it is subject to potential problems such as human error, weather delays, etc.
By the late 1990s, technology had developed that would allow electric meters to store consumption data electronically, rather than through rotating wheels and dials as in electromechanical meters. These electronic meters could also be combined with "automated meter reading" ("AMR") technology to allow consumption data to be retrieved remotely, thereby eliminating the need to manually read meters.
Cannon is a Minnesota corporation headquartered in Minneapolis. Among other things, it produces AMR technology for use with electronic electric meters, and it combines that technology with electronic meters to form automated meter reading systems, which it then sells to end users (i.e., power companies).
Sensus is a Delaware corporation headquartered in North Carolina. It is a technology and communications company providing data collection and metering solutions to utility companies worldwide.
Vishay is a Delaware corporation headquartered in Pennsylvania. It manufactures electrical components, including the key component in this case that allegedly failed.
In 1999, Sentec Limited ("Sentec"), a small British technology start-up, approached Sensus with a design for a new electronic sensor that could be used in an electric meter. (England 5/26/10 Dep. Tr. at 26-27; England 5/27/10 Dep. Tr. at 32-34, 38-42.) Sensus liked the technology and decided to license it from Sentec. (Id. at 41-42.) It also contracted with Sentec to design an electric meter incorporating the electronic sensor. (England 5/26/10 Dep. Tr. at 27.) The intent was to design a "base" electronic meter that could be fitted with AMR technology to transmit consumption data to purchasers (power companies).
Over the following year, Sentec developed a fully functioning electronic electric meter for Sensus, known as the iCon Form 2S meter (the "iCon Meter"). Sentec performed the design work for the iCon Meter, including the schematic and layout for its internal components. (Id. at 28-29.)
Sentec designed the iCon Meter such that the power necessary to operate it passed through a component known as a "capacitor." (England 5/27/10 Dep. Tr. at 348; Steiner Dep. Tr. at 14.) A capacitor is a device designed to hold an electrical charge. The New Encyclopedia Britannica 823 (15th ed. 2010). Capacitors can be constructed in many different shapes and sizes and with a variety of materials, and hence the ability of different capacitors to hold a charge varies. A capacitor's ability to hold a charge—known as its "capacitance"—is measured in units called Farads, denoted by the symbol "F." Id.
In the iCon Meter, the capacitor was intended to limit the amount of electric current passing through to the meter's internal components, including the electricity-use sensor, to prevent those components from being damaged in case of excess voltage. (England 5/26/10 Dep. Tr. at 45; England 5/27/10 Dep. Tr. at 148-49.) But because the power necessary to operate the Meter passed through the capacitor, the meter would stop functioning— meaning electricity would flow to a home without being recorded—if the capacitance of the capacitor fell too low. (Id. at 148-49.)
All capacitors experience what is known as "corona discharge" when exposed to a certain voltage of electricity (which voltage level varies by capacitor). (Henderson Dep. Tr. at 38-39.) The technical explanation for why corona discharge occurs is unimportant. What is important is that corona discharge typically will "short out" a capacitor, which could potentially cause a fire. (Id. at 39.) Some capacitors, however, are known as "self-healing." A "self-healing" capacitor is designed to continue functioning, rather than short out, if exposed to power "spikes" or other temporary voltage increases. (Id.: Dungan Decl. Ex. 15 at 13; Southerland Dep. Tr. at 96.) But when such a capacitor "heals," it loses some of its capacitance. (Dungan Decl. Ex. 15 at 13.) As a result, a capacitor constantly exposed to voltage above the "corona onset point" will constantly self-heal and, accordingly, constantly lose capacitance.
The capacitor Sentec selected for the iCon Meter was manufactured by Vishay and is known as the X2 Class MKP 336 2 electromagnetic interference suppression film capacitor (the "336 Capacitor"). The 336 Capacitor had a rated capacitance of 470 nanoFarads (nF).
Vishay produced a specification sheet for the 336 Capacitor containing certain information about its salient qualities. (See Hayes Aff. Ex. 9; Dungan Decl. Ex. 5.) With respect to the parties' claims, the specification sheet is noteworthy in four respects:
• First, it indicated that the 336 Capacitor has a "tolerance" of plus or minus 20
• Second, it contained no information about the 336 Capacitor's corona onset point. Rather, it merely indicated that the Capacitor was rated for use at 275 volts. (E.g., id. Ex. 11.) Eventually, the parties learned that the 336 Capacitor experienced corona discharge beginning at approximately 220-230 volts. (Stevens 4/14/10 Dep. Tr. at 104; Henderson Dep. Tr. at 39.)
• Third, it contained an "Application Notes" section providing that the 336 Capacitor was "[f]or X2 electromagnetic interference suppression in across the line applications." (Dungan Decl. Ex. 11 (emphasis added).) In the iCon Meter, however, the 336 Capacitor was used in a "series impedance" application, rather than an "across the line" application. (England 5/26/10 Dep. Tr. at 31.)
• Fourth, it indicated that the 336 Capacitor had passed international testing standard "IEC 60384.14 2nd edition." That standard subjects a capacitor to a 1,000 hour "accelerated life" test, after which, in order to pass, it cannot have lost more than 10% of its initial capacitance. (Id. at 58.) Although the 336 Capacitor passed that test, it nevertheless had a tendency to lose between 2 and 6 nF of capacitance for every 1.000 hours of use. (Stevens 4/14/10 Dep. Tr. at 144.)
In 2003, Sensus approached Cannon to inquire about using Cannon's AMR technology with the iCon Meter. (Rummel Dep. Tr. at 45; Mazza 4/7/10 Dep. Tr. at 74.) At the time, Cannon was investigating meter manufacturers with which it could incorporate its AMR technology. (Branca 3/23/10 Dep. Tr. at 44.) Cannon agreed to pair its AMR technology with Sensus's iCon Meter due to the meter's "overall design excellence and flexibility." (Palen Decl. Ex. 7.) The two companies later executed a Product Development Agreement providing that Cannon would "undertake the design and development" of technology to be fully integrated into the iCon Meter. (Id. Ex. 9.)
During the next year, Cannon worked to integrate its AMR technology into the iCon Meter. The companies produced a test product combining the two that went through "beta trials" and "field" testing (i.e., actual deployment and use). (Branca 3/23/10 Dep. Tr. at 75-76; Palen Decl. Ex. 12.) Ultimately, their efforts succeeded in producing a combined metering product called the MCT410iL meter (the "MCT Meter"). It was ready to ship to customers in September 2004. (Id. Ex. 13.)
Cannon was the exclusive seller of the MCT Meter. (Cannon 3/24/10 Dep. Tr. at 81; Branca 3/23/10 Dep. Tr. at 97-98; McCall Dep. Tr. at 107.) When one of its customers ordered the meter, Cannon would submit a purchase order to Sensus for the "base" iCon Meter. (Branca 3/23/10 Dep. Tr. at 97; Rummel Dep. Tr. at 110-11.) Sensus would, in turn, contact Epic Technologies, Inc. ("Epic"), a contract manufacturer of both the iCon Meter
According to Sensus, its regular business practice was to send a purchase acknowledgement whenever it received a purchase order from Cannon. (Mazza 4/7/10 Dep. Tr. at 108-09; Springer Decl. ¶ 3.)
Sensus also sold its iCon Meter to Hunt Technologies, Inc. ("Hunt"), a Cannon competitor, which incorporated its own AMR technology into the meter. In late 2005, Hunt contacted Sensus and informed it that approximately 1,000 of the meters it had purchased from Sensus were not functioning properly. (Mazza 4/7/10 Dep. Tr. at 84.) Sensus later determined that the 336 Capacitors in Hunt's meters were demonstrating a capacitance of between 160 and 230 nF, well below the 470 nF at which they were rated and too low to power the meter consistently. (Hayes Aff. Ex. 12.) Sensus then contacted Vishay for its assistance in identifying the cause of the capacitance drop. (Id.) It also requested the same help from Sentec. (England 5/26/10 Dep. Tr. at 89-90.)
Vishay obtained samples of the capacitors in the Hunt meters and analyzed them. On November 7, 2005, it issued a report (the "8D Report") to Sensus regarding its findings. (Dungan Decl. Ex. 17.)
According to Sensus, notwithstanding the 8D Report, it was not aware of a design defect in the iCon Meter.
Regardless, after Hunt reported its problems to Sensus, Sentec performed additional testing of the power supply in the iCon Meter. (England 5/26/10 Dep. Tr. at 117-18.) Following that testing, Sentec recommended that Sensus replace the 336 Capacitor with a different capacitor manufactured by EPCOS, Inc. ("EPCOS"). (Id.) Sensus agreed and began replacing the 336 Capacitor in all iCon Meters manufactured on or after January 20, 2006. (Mazza 5/11/10 Dep. Tr. at 21-22.) Sensus did not disclose this change to Cannon, and it continued selling Cannon iCon Meters with the 336 Capacitor between November 7, 2005 (the date of Vishay's 8D Report) and January 20, 2006 (the date it replaced the 336 Capacitor with the EPCOS capacitor). (Steiner Dep. Tr. at 181-82.) It later replaced the EPCOS capacitor with the "X2 1772 series" capacitor recommended by Vishay. (England 5/26/10 Dep. Tr. at 169.) There have been no reported power problems with iCon Meters manufactured on or after January 20, 2006. (Mazza 6/18/10 Dep. Tr. at 76.)
In early 2008, one of Cannon's MCT Meter customers, North Star Electric ("North Star"), reported that some of its Meters were in a "strange operating state." (Branca 3/23/10 Dep. Tr. at 116.) Cannon sent those meters to its in-house engineering department, which determined that their power supply was unstable. (Id. at 116-17.) It then contacted Sensus, which advised Cannon that it should check the capacitor because the meters at issue contained the 336 Capacitor, which Sensus had not used for more than two years. (Id. at 117.) According to Cannon, this was the first time it learned that the 336 Capacitor could degrade and cause power
There is no dispute among the parties that the 336 Capacitors in many iCon Meters failed because they lost capacitance. What is not clear, however, is whether that occurred because of (a) corona discharge and the "self-healing" nature of the Capacitor; (b) use of the Capacitor in a "series impedance" application rather than an "across the line" application; (c) the Capacitor's tendency to lose between 2 and 6 nF of capacitance for every 1,000 hours of use; or (d) some combination of the foregoing.
In December 2008, Cannon commenced the instant action against Sensus, asserting claims for breach of warranty and breach of contract; Sensus filed an Answer denying Cannon's allegations. Sensus later amended its Answer to assert third-party claims against Vishay. After some additional amendments, the parties' pleadings now assert the following claims: Cannon asserts claims for breach of warranty, breach of contract, fraud, and violation of Minnesota's Deceptive Trade Practices Act ("DTPA"), Minnesota Statutes Section 325D.44, against Sensus, while Sensus asserts claims against Vishay for contribution and indemnification, breach of express warranty, breach of implied warranty of merchantability, and violation of the DTPA.
Following extensive discovery, Sensus now moves for summary judgment on Cannon's claims, and Vishay moves for summary judgment on Sensus's third-party claims. The arguments have been "briefed to death," United States ex rel. Robinson v. Northrop Grumman Corp., No. 89 C 6111, 2002 WL 31478259, at *2 (N.D.Ill. Nov. 5, 2002), including supplemental briefing requested by the Court to clarify certain issues in advance of oral argument. The Court held a lengthy hearing on the Motions on August 16, 2010, and they are now ripe for disposition.
Summary judgment is proper if, drawing all reasonable inferences in favor of the nonmoving party, there is no genuine issue as to any material fact and the moving party is entitled to judgment as a matter of law. Fed.R.Civ.P. 56(c); Celotex Corp. v. Catrett, 477 U.S. 317, 322-23, 106 S.Ct. 2548, 91 L.Ed.2d 265 (1986). The moving party bears the burden of showing that the material facts in the case are undisputed. Id. at 322, 106 S.Ct. 2548; Mems v. City of St. Paul, Dep't of Fire & Safety Servs., 224 F.3d 735, 738 (8th Cir.2000). The Court must view the evidence, and the inferences
In light of the foregoing, the Court views the facts in the light most favorable to Cannon when reviewing Sensus's Motion, and in the light most favorable to Sensus when reviewing Vishay's Motion.
As noted above, Cannon has asserted four claims against Sensus: breach of contract, breach of warranty, fraud, and violation of the DTPA. On its face, the breach-of-warranty claim concerns only warranties implied under the law, namely, the implied warranties of merchantability and fitness for a particular purpose. (See Doc. No. 33 ¶¶ 15-18.) Yet, both Cannon and Sensus have construed Cannon's breach-of-contract claim to assert breach of an express warranty by Sensus. (See Sensus Mem. in Supp. at 11-12; Cannon Mem. at 26-34.) The Court follows their lead and will analyze the breach-of-contract claim as if it asserts breach of an express warranty. And the Court begins its analysis with that claim.
In a typical express-warranty case, the plaintiff points to a document containing the warranty allegedly breached by the defendant. That is not the case here. While Sensus contends that the "Terms of Sale" it sent with its purchase acknowledgements contains the "express warranty" (Sensus Mem. in Supp. at 11 n. 4), Cannon disputes that assertion, arguing that the "Terms of Sale" was not sent with each purchase acknowledgement. Rather, it argues that Sensus offered an oral warranty covering the iCon Meter. (Cannon Mem. at 26.)
Regardless of how the warranty arose, however, the parties agree that Sensus warranted the iCon Meters it sold to Cannon for 12 months from the date of installation or 18 months from the date of shipment, whichever occurred first. (Sensus. Mem. in Supp. at 12; Cannon Mem. at 26.) And it is for this reason that Cannon's claim fails, because none of the iCon Meters at issue failed during the express-warranty period.
Cannon does not dispute Sensus's claim that its express warranty expired at the latest on July 20, 2007—18 months from January 20, 2006, the date Sensus replaced the 336 Capacitor with the EPCOS capacitor. (Cannon Mem. at 26.) Nor does Cannon argue that any of its MCT Meters containing the 336 Capacitor failed on or before that date. Hence, the breach-of-express-warranty claim necessarily fails. See, e.g., Abraham v. Volkswagen of Am., Inc., 795 F.2d 238, 250 (2d Cir.1986) ("[A]n express warranty does not cover [defects
Cannon argues, however, that Sensus breached its express warranty because all of the iCon Meters were defective on the date they were sold, since they contained a part doomed to fail. (Cannon Mem. at 26-27.) This argument lacks merit. As this Court has noted previously, a claim alleging breach of an express warranty of future performance cannot accrue until a defect actually manifests itself. See O'Neil v. Simplicity, Inc., 553 F.Supp.2d 1110, 1115 (D.Minn.2008) (Kyle, J.) ("It is simply not enough for a plaintiff to allege that a product [contains a] defect.... [T]he plaintiff must instead allege an actual manifestation of the defect that results in some injury in order to state a cognizable claim for breach of warranty.") (emphasis in original), aff'd, 574 F.3d 501 (8th Cir.2009). That is consistent with the Uniform Commercial Code ("UCC"), which provides that a "breach of warranty occurs when tender of delivery is made, except that where a warranty explicitly extends to future performance of the goods ... the cause of action accrues when the breach is or should have been discovered." UCC § 2-725(2) (emphasis added).
Accordingly, even if Cannon were correct that the iCon Meters were "defective" when purchased, its express-warranty claim would still fail because that defect did not manifest itself until after the warranty period had ended. See, e.g., Canal Elec. Co. v. Westinghouse Elec. Co., 973 F.2d 988, 993 (1st Cir.1992) ("[T]ime-limited warranties do not protect buyers against hidden defects ... that may exist before, but typically are not discovered until after, the expiration of the warranty period.").
Under the UCC, a warranty of merchantability is implied into every contract for the sale of goods, unless disclaimed or otherwise excluded. UCC § 2-314(1). Such a warranty ensures that the goods will be "fit for the ordinary purposes for which such goods are used." Id. § 2-314(2)(c). An implied warranty of fitness for a particular purpose also is implied into a contract for the sale of goods, unless
Here, Cannon concedes that the particular purpose for which the iCon Meter was used—measuring electricity usage—was the same as its ordinary use. (Branca 3/23/10 Dep. Tr. at 247-48.) Hence, the two warranties merge. See, e.g., Cartillar v. Turbine Conversions, Ltd., 187 F.3d 858, 861 n. 5 (8th Cir.1999) (where "the particular purpose for which goods are to be used coincides with their general functional use, the implied warranty of fitness for a particular purpose merges with the implied warranty of merchantability"). The question for resolution, then, is whether there exists a genuine issue that the iCon Meter was not fit for its ordinary use. The Court determines that question must be answered in the affirmative.
The implied warranty of merchantability is breached only when a product "is defective to a normal buyer making ordinary use of the product." Peterson v. Bendix Home Sys., Inc., 318 N.W.2d 50, 53 (Minn.1982) (emphasis added); accord, e.g., Kelley Metal Trading Co. v. Al-Jon/United, Inc., 877 F.Supp. 1478, 1483 (D.Kan.1995) (warranty extends to an "ordinary buyer in a normal commercial transaction") (emphasis added); Lipnick v. Reisinger, 168 Ohio App.3d 253, 859 N.E.2d 600, 604 (2006) (same). Sensus argues at the outset that no implied warranty arose here because Cannon was not a "normal buyer" of the iCon Meter, but rather was a "sophisticated business entit[y] whose skill and knowledge regarding electrical meters" was equal to its own. (Sensus Mem. in Supp. at 14.)
Some courts have, indeed, recognized that where a buyer is sophisticated and possesses skill or knowledge about a product equal or superior to the seller's, no implied warranty of merchantability arises. See, e.g., Binks Mfg. Co. v. Nat'l Presto Indus., Inc., 709 F.2d 1109, 1121-22 (7th Cir.1983); Price Bros. Co. v. Phila. Gear Corp., 649 F.2d 416, 424 (6th Cir.1981). Those cases, however, are inapposite here because they involved the purchase of products that the buyers helped the sellers design. There is no evidence before the Court that Cannon had any input in the design of the iCon Meter—indeed, the record reflects that Sensus designed the meter well before it approached Cannon in 2003 to inquire about forming a partnership. While Sensus points out that Cannon helped design the MCT Meter, that is not the product Cannon was buying from Sensus. Rather, Cannon purchased the iCon Meter from Sensus, and then worked with Sensus to integrate its AMR technology into that product.
Moreover, Binks and Price were predicated on the fact that the products at issue were unique and, hence, there was "no proof or evidence pointing to a record of past years on which a determination of [the product's] ordinary purpose could be found." Binks, 709 F.2d at 1122 (citing Price, 649 F.2d at 424). But the product
Simply put, Binks and Price are not applicable here. But even if they were, and even if Sensus were correct that Cannon had some input on the design of the iCon Meter, on the present record the Court would conclude that there exists a genuine issue as to the comparative level of Cannon's skill and knowledge regarding the meter's design. That conclusion is consistent with an analogous—and instructive —provision of the UCC. Section 2-316(3)(b) provides that "when the buyer before entering into the contract has examined the goods or the sample or model as fully as desired ... [,] there is no implied warranty with regard to defects which an examination ought in the circumstances to have revealed." See also Driscoll v. Standard Hardware, Inc., 785 N.W.2d 805, 816-17 (Minn.Ct.App.2010). That is the real tenor of Sensus's argument here: Cannon had more than a year to work with Sensus in developing and "beta testing" the MCT Meter and, hence, it was in a position to learn about the problem with the 336 Capacitor. (See Sensus Mem. in Supp. at 14.) Yet, there is a dearth of evidence in the record to support the conclusion that Cannon should have learned of the defect with the 336 Capacitor through such testing. Indeed, Sensus itself did not recognize the problem when designing the iCon Meter or testing it. Moreover, Cannon only tested the MCT Meter for approximately one year, but it took several years for it to fail "in the field." Under these circumstances, where the defect was "not obvious upon mere examination," whether it should have been discovered "is a question for the jury." Canadian Pac. Ry. Co. v. Williams-Hayward Protective Coatings, Inc., No. 02 C 8800, 2005 WL 782698, at *14 (N.D.Ill. Apr. 6, 2005); accord, e.g., Henry Heide, Inc. v. WRH Prods. Co., 766 F.2d 105, 110-11 (3d Cir.1985); HWH Corp. v. Deltrol Corp., No. C07-0059, 2009 WL 734710, at *6 (N.D.Iowa Mar. 19, 2009).
For all of these reasons, the Court concludes that summary judgment based on Cannon's so-called "equal or superior knowledge" is inappropriate.
Sensus next argues that even if an implied warranty arose, it was expressly disclaimed in the "Terms of Sale" it sent with every purchase acknowledgement. (Sensus Mem. in Supp. at 12-13.) As noted above, however, there is a dispute whether Sensus routinely sent the "Terms of Sale" with those acknowledgements. Given that dispute, the Court cannot determine at the summary-judgment stage whether Sensus validly disclaimed implied
In its final implied-warranty argument, Sensus contends that the term of any such warranty must be limited to that of the express warranty—that is, no more than 18 months. (Sensus Mem. in Supp. at 17-18.) And, like the express-warranty claim, Sensus argues that "[b]ecause there is no evidence that any of the Meters ... suffered capacitor related failures on or before July 20, 2007, Cannon's claims for breach of implied warranties fail as a matter of law." (Id. at 17.) This argument, however, is predicated on a misapprehension of implied warranties.
As noted above, the breach-of-express-warranty claim accrued only when Cannon's meters began to fail. This is because the express warranty extended to the future performance of the meters, and under the UCC, "where a warranty explicitly extends to future performance of the goods[,] ... the cause of action [for breach of warranty] accrues when the breach is or should have been discovered." UCC § 2-725(2). However, an implied warranty, by its very nature, cannot explicitly extend to future performance of a product. Highway Sales, Inc. v. Blue Bird Corp., 559 F.3d 782, 788-89 (8th Cir.2009). Accordingly, a "breach of implied warranty occurs, and the claim accrues, when tender of delivery is made." Id. (citation omitted).
The foregoing makes clear why Sensus's argument must be rejected. For purposes of the implied-warranty claim, whether the meters failed within the time period delineated by the express warranty is not dispositive. Rather, the issue is whether Sensus breached the implied warranty of merchantability when the claim accrued, that is, when it tendered delivery of the iCon Meters. In other words: were the meters "defective" when Sensus tendered them?
Under the facts here, a reasonable jury could answer this question, "Yes." A product is defective if it "fail[s] in normal use and cause[s] the injury complained of." Farr v. Armstrong Rubber Co., 288 Minn. 83, 179 N.W.2d 64, 69 (1970). The evidence shows that the iCon Meters sold to Cannon failed when put to their normal use—measuring electricity usage. Although the failures happened several years after the meters were sold, that fact is relevant to show whether they were defective at sale. See, e.g., City of Stoughton v. Thomasson Lumber Co., 269 Wis.2d 339, 675 N.W.2d 487, 493 (Wis.Ct.App.2003) ("Evidence that the goods break or physically deteriorate after delivery may be relevant to whether the goods were fit at the time of delivery for the ordinary purpose for which they are used."); 141 S. Main, Inc. v. Magic Fingers, Inc., 49 Ill.App.3d 724, 7 Ill.Dec. 444, 364 N.E.2d 605, 608 (1977) (for purposes of implied warranty, product may be defective even if defect did not "manifest itself immediately" upon sale); Mosier v. Am. Motors Corp., 303 F.Supp. 44, 51 (S.D.Tex.1967) (breach of implied warranty of merchantability requires evidence that product was defective when sold; such evidence existed because it was shown that product "would not stand up under normal use").
What Sensus seems to be arguing is that the iCon Meters were not defective when sold because they did not fail within 18 months, the maximum length of the express warranty. But there is a plethora of evidence in the record to suggest that the expected life of the meters was far more than 18 months. (See, e.g., Cannon Decl. ¶ 4 (Sensus told Cannon the meters had an expected 15-year life); England 5/27/10 Dep. Tr. at 133 (Sensus discussed with Sentec at design meetings that expected
For all of these reasons, the Court concludes that genuine issues of material fact preclude summary judgment on Cannon's implied-warranty claim.
Cannon asserts that Sensus engaged in fraud by failing to disclose that the 336 Capacitor was defective. (Cannon Mem. at 34.) Before analyzing this claim, the Court must briefly address a choice-of-law issue.
Sensus argues that the fraud claim is governed by Pennsylvania law due to the choice-of-law clause in the "Terms of Sale." As a result, it contends that the claim is barred by the economic-loss doctrine, which (generally speaking) precludes the recovery in tort for claims flowing from a contract. See, e.g., Werwinski v. Ford Motor Co., 286 F.3d 661, 671 (3d Cir.2002). Cannon does not appear to quibble with the notion that its fraud claim would be barred by the economic-loss doctrine under Pennsylvania law. However, it contends that Minnesota law, not Pennsylvania law, must apply to the claim, because it disputes whether Sensus sent the "Terms of Sale" with each purchase acknowledgement. And in Minnesota, fraud claims are not barred by the economic-loss doctrine. See Minn.Stat. § 604.10(e).
Because there exists a genuine issue of material fact whether the "Terms of Sale" was sent with each purchase acknowledgement, the Court cannot resolve at this juncture whether Pennsylvania law (which bars the claim) or Minnesota law (which does not) is applicable here. Hence, it must proceed to analyze this claim under Minnesota law.
As a general rule, under Minnesota law one party to a transaction "has no duty to disclose material facts to the other." Taylor Inv. Corp. v. Weil, 169 F.Supp.2d 1046, 1064 (D.Minn.2001) (Tunheim, J.) (citing L & H Airco, Inc. v. Rapistan Corp., 446 N.W.2d 372, 380 (Minn.1989)). Hence, fraud does not exist based solely on the failure to disclose facts unless "special circumstances" require that disclosure. Am. Computer Trust Leasing v. Boerboom Int'l, Inc., 967 F.2d 1208, 1211-12 (8th Cir.1992) (citing L & H Airco, 446 N.W.2d at 380). Three such "special circumstances" have been recognized by the Minnesota Supreme Court: where there exists a confidential or fiduciary relationship between the parties; where disclosure is necessary to clarify information already disclosed, which would otherwise be misleading; or where the non-disclosing party "has special knowledge of material facts to which the other party does not have access." L & H Airco, 446 N.W.2d at 380; accord, e.g., Heidbreder v. Carton, 645 N.W.2d 355, 367 (Minn.2002); Richfield Bank & Trust Co. v. Sjogren, 309 Minn. 362, 244 N.W.2d 648, 650 (1976).
Cannon proceeds on the third prong, arguing that "Sensus fraudulently concealed
According to Cannon, Sensus knew as of November 7, 2005—the date of the first 8D Report from Vishay—that it was "misusing" the 336 Capacitor, which would lead the iCon Meter to fail. (Id. at 31.) Sensus disputes that assertion and claims that it was unsure at that time whether there existed a systemic problem with the meter. A reasonable jury, however, could conclude from the 8D Report that Sensus was aware of a defect inherent in the meter's design. Moreover, there was no way Cannon could have been aware of this information. It did not receive the 8D Report. And while Sensus asserts that it informed Cannon of the Report's contents in December 2005, Cannon hotly disputes that assertion.
If a jury were to credit Cannon's version of events, it could conclude that (1) Sensus knew of the problem with the meter in November 2005, (2) Cannon was not aware of the problem and had no avenue to obtain that knowledge, and (3) Sensus failed to disclose the problem before selling additional meters to Cannon. That is sufficient to support a finding of fraud. See Valspar Refinish, Inc. v. Gaylord's, Inc., 764 N.W.2d 359, 368 (Minn.2009).
The Court agrees with Sensus, however, that any damages flowing from its allegedly fraudulent conduct must be limited on the facts here. Cannon alleges that Sensus became aware of the problem with the iCon Meter sometime on or after November 7, 2005, the date of Vishay's first 8D Report. Hence, the fraud could only have occurred, at the earliest, on November 7, 2005. Since Sensus stopped selling iCon Meters containing the 336 Capacitor on January 20, 2006, Cannon's damages are necessarily limited to the period from that date to the date it received the 8D Report from Vishay.
The Court need not linger long on Cannon's claim under the DTPA. It is well-settled that monetary damages are not available under that statute; "the sole statutory remedy for deceptive trade practices is injunctive relief." O'Neil, 553 F.Supp.2d at 1113 n. 4 (citations omitted); accord, e.g., Summit Recovery, LLC v. Credit Card Reseller, LLC, Civ. No. 08-5273, 2010 WL 1427322, at *5 (D.Minn. Apr. 9, 2010) (Doty, J.); State ex rel. Hatch v. Cross Country Bank, Inc., 703 N.W.2d 562, 573 (Minn.Ct.App.2005); Alsides v. Brown Inst., Ltd., 592 N.W.2d 468, 476 (Minn.Ct.App.1999). Here, the deceptive conduct alleged by Cannon occurred in the past: Sensus's (mis)representations concerning the iCon Meters containing the 336 Capacitor, which Sensus no longer sells. Accordingly, relief under the DTPA cannot be had. See Summit Recovery, 2010 WL 1427322, at *5.
Lastly, Sensus argues that if any of Cannon's claims survive its Motion, the recoverable damages must be limited, for two reasons.
First, it argues that the "Terms of Sale" caps any damages at the amount paid for the meters in question. (Sensus Mem. in Supp. at 29-32.) Because the Court concludes, as noted above, that there exists a genuine issue whether the "Terms of Sale" was sent with each purchase acknowledgement, it will not limit Cannon's damages on this basis.
Second, it argues that any breach-of-warranty damages must be limited to meters delivered on or after December 23, 2004, since Cannon commenced this action on December 23, 2008, and Minnesota has a four-year statute of limitations for breach-of-warranty actions. (Id. at 32.) Cannon responds that it may recover for iCon Meters purchased before that date because Sensus fraudulently concealed the meter's defect, thereby tolling the statute of limitations. (Cannon Mem. at 30-33.) Yet, fraudulent concealment requires more than simply an omission; it requires an act or statement—"something of an affirmative nature"—designed to prevent discovery of a cause of action. Wild v. Rarig, 302 Minn. 419, 234 N.W.2d 775, 795 (1975). "In no case ... is mere silence or failure to disclose sufficient in itself to constitute fraudulent concealment." Helleloid v. Indep. Sch. Dist. No. 361, 149 F.Supp.2d 863, 869 (D.Minn.2001) (Erickson, M.J.); accord, e.g., Appletree Square 1 Ltd. P'ship v. W.R. Grace & Co., 815 F.Supp. 1266, 1275 (D.Minn.1993) (Kyle, J.). The only alleged "concealment" here was an omission: Sensus's failure to disclose the defective design of the iCon Meter. Accordingly, damages for the breach-of-implied-warranty claim must be limited to iCon Meters sold on or after December 23, 2004.
Sensus's claims against Vishay are similar to Cannon's claims against Sensus, with some slight variations. The claims are discussed in turn below.
Sensus argues that the specification sheet for the 336 Capacitor created an express warranty that Vishay breached in three ways. (Sensus Mem. in Opp'n at 18-26.) None of its contentions passes muster.
Sensus notes that the specification sheet rates the 336 Capacitor for use at 275 volts, but neglects to mention that it suffers corona discharge at 220-230 volts. (Id. at 21-22.) It further notes that the specification sheet fails to indicate that the Capacitor cannot be used in a "series impedance" application. (Id. at 22-25.) But a failure to include information in the
Sensus also argues that the tolerance listed on the specification sheet-indicating that the 336 Capacitor was rated at 470 nF ± 20%—was violated because all 336 Capacitors produced by Vishay fell below 470 nF and, hence, were not "normally distributed." (Sensus Mem. in Opp'n at 20.) But the listed tolerance does not, in the Court's view, create a warranty that Vishay's 336 Capacitors would be distributed in a "bell curve" both above and below 470 nF. Rather, it merely warranted that each individual 336 Capacitor produced by Vishay would have a capacitance "out of the box" between 376 nF (470 nF minus 20%) and 564 nF (470 plus 20%). And there is no evidence before the Court that any of the 336 Capacitors Sensus purchased from Vishay had a capacitance below 376 nF "out of the box."
Sensus alleges that Vishay breached the implied warranty of merchantability because the 336 Capacitor was not fit for its ordinary use. (Sensus Mem. in Opp'n at 26-28.) Vishay argues that this claim must be dismissed because Sensus misused the 336 Capacitor in a "series impedance" application rather than an "across the line" application. (Vishay Mem. at 18-19.) The problem with this argument is that the "ordinary use" of the 336 Capacitor is in dispute.
The crux of Vishay's argument is that the specification sheet's "Application Notes"—which states that the capacitor was intended "[f]or X2 electromagnetic interference suppression in across the line applications" (Dungan Decl. Ex. 11)—sets forth the only appropriate use for the 336 Capacitor. (See Hear. Tr. at 43 ("They're the specified uses. They are ... what the capacitor is for.").) In fact, according to Vishay, Sensus admitted that "application notes in specification sheets indicate which particular applications are appropriate for the component." (Vishay Mem. at 12.) But the evidence cited by Vishay to support that argument—deposition testimony from Steiner—contains no so such admission. Indeed, when asked if the applications listed on a product's specification sheet are its only appropriate uses, Steiner answered, "It's a suggestion." (Steiner Dep. Tr. at 63 (emphasis added).)
The determination of the 336 Capacitor's "ordinary use" is not as simple as Vishay would have the Court believe. According to the leading commentators on the UCC, courts typically look to (inter alia) a product's "usage in the trade" and the "characteristics exhibited by goods of the same class that are manufactured by persons other than the seller in question" when determining a product's ordinary use. 1 James J. White & Robert S. Summers, Uniform Commercial Code § 9-13 (5th ed. 2009). Here, those factors suggest that a "series impedance" application may indeed be an "ordinary use" for the 336 Capacitor.
Notably, at least one Sensus witness acknowledged in his deposition that the 336 Capacitor in some circumstances "can be used in a series impedance application." (Stevens 4/14/10 Dep. Tr. at 176.) Moreover, there is evidence indicating that several other Vishay customers were using the 336 Capacitor in "series impedance" applications. (Id. at 171-72; Stevens
Under these facts, the Court concludes that there exists a genuine issue whether an ordinary use of the 336 Capacitor is in a "series impedance" application. As a result, the Court determines that Vishay's Motion must be denied with respect to the implied-warranty claim, because there is no dispute that the 336 Capacitor failed when used in that fashion. Indeed, Vishay conceded in the 8D Reports that the capacitor was not fit for that purpose. (Dungan Decl. Exs. 17-19.)
Vishay also argues that Sensus "misused" the 336 Capacitor in two other ways. First, it notes that the capacitor is self-healing, meaning that "it is expected to degrade over time." (Vishay Reply at 15.) Hence, it contends Sensus misused the capacitor because the iCon Meter's power supply was directed through a component it knew would eventually degrade. (Id. at 16 ("[W]hat Sensus needed was a capacitor that . . . would not lose capacitance due to self-healing characteristics.").) Yet, this argument ignores that Vishay's suggested replacement for the 336 Capacitor was itself an X2 class, self-healing capacitor. (Dungan Decl. Exs. 17-19.) It also ignores that Sensus later used that replacement capacitor in the iCon Meter without problems. (England 5/26/10 Dep. Tr. at 169; Mazza 6/18/10 Dep. Tr. at 76.) Hence, there is no merit to the contention that Sensus was "misusing" the 336 Capacitor because of its self-healing capabilities.
Second, Vishay argues that Sensus erred by designing the iCon Meter in a way that would expose the capacitor to constant voltage, since it had "a tested life of only 1,000 hours." In support of that contention, it points to the capacitor's certification under the IEC 60384.14 2nd edition testing standard (the so-called "accelerated life" test discussed above). (Vishay Mem. at 9; Vishay Reply at 14-15.) But that certification does not aid Vishay's argument. While it is true that the capacitor was certified not to lose more than 10% capacitance after 1,000 hours of "accelerated" (i.e., stressed) use, the certification says nothing about how long the capacitor could be expected to function. (See England 5/26/10 Dep. Tr. at 59.) Indeed, it would make little sense for Vishay to acknowledge that the 336 Capacitor loses 2-6 nF of capacitance for every 1,000 hours of use (Stevens 4/14/10 Dep. Tr. at 144) if it were only expected to last for 1,000 hours.
Sounding a familiar refrain (see supra at 768-69), Vishay argues that Sensus's DTPA claim must be dismissed because only injunctive relief is authorized under the statute, and Sensus's Third-Party Complaint merely seeks damages
The Court is hesitant to construe Sensus's boilerplate language, which appears in nearly every pleading filed in this Court, as sufficient to preserve a claim for injunctive relief when such relief is not specifically pleaded in connection with a claim.
In support of its claim, Sensus argues that Vishay must amend the 336 Capacitor's specification sheet in three ways. (Sensus Mem. in Opp'n at 32.) First, it asserts that Vishay must list the tolerance of the 336 Capacitor as 470 nF minus 20%, rather than 470 nF plus or minus 20%, since Vishay intentionally aims for the low end of the range in its manufacturing process. But, as discussed in more detail above, there is nothing misleading about Vishay's tolerance specification — it indicates that any "out of the box" 336 Capacitor Vishay manufactures can have an initial capacitance as low as 376 nF, and there is no evidence that is not the case. As long as Vishay's capacitors fall within the specified range, the tolerance on the specification sheet is accurate. Second, Sensus asserts that Vishay must disclose that capacitance drops over time. But this is true of all self-healing capacitors, and hence no reasonable buyer could expect the 336 Capacitor to maintain its capacitance forever. Third, Sensus asserts that Vishay should be required to indicate the corona onset point for the 336 Capacitor. But corona discharge is well-known in the electrical industry, and Sensus's own witnesses testified it is not standard industry practice to include corona onset information in specification sheets for capacitors. (Mazza 6/18/10 Dep. Tr. at 123; Wollenberg Dep. Tr. at 257-58.)
Simply put, the Court does not believe that any of the changes Sensus seeks are necessary to prevent the specification sheet from misrepresenting the 336 Capacitor's "standard, quality or grade," Dennis Simmons, D.D.S., P.A. v. Modern Aero, Inc., 603 N.W.2d 336, 339 (Minn.Ct.App. 1999), or to prevent it from suggesting it possesses "characteristics, . . . benefits, or qualities" that it lacks, Minn.Stat. § 325D.44. Accordingly, the DTPA claim cannot stand. Id.
Sensus's final claim against Vishay seeks contribution and indemnification "[i]n the event Cannon is successful in its claims" against Sensus. (Sensus Mem. in Opp'n at 35, 38.) Vishay argues that this claim must be dismissed because it violated no duties, contractual or otherwise, because the 336 Capacitor was not defective and performed as promised in the specifications. (Vishay Mem. at 22-23.)
Vishay also argues that this claim is barred by Minnesota's version of the economic-loss doctrine. (Vishay Mem. at 29-31.) As Sensus correctly notes, however, this contention has been squarely rejected by the Minnesota Court of Appeals — the economic-loss doctrine precludes actions in tort, but contribution-indemnity is an equitable claim and therefore is not precluded. See City of Willmar v. Short-Elliott-Hendrickson, Inc., 512 N.W.2d 872, 876 (Minn. Ct.App.1994).
Based on the foregoing, and all the files, records, and proceedings herein,
1. Sensus's Motion for Summary Judgment (Doc. No. 70) is
2. Vishay's Motion for Summary Judgment (Doc. No. 76) is
3. Cannon's Motion to Strike (Doc. No. 105) is