Royce Young v. Pollock Engineering, 04-3428 (2005)

Court: Court of Appeals for the Eighth Circuit Number: 04-3428 Visitors: 22
Filed: Nov. 15, 2005
Latest Update: Mar. 02, 2020
Summary: United States Court of Appeals FOR THE EIGHTH CIRCUIT _ No. 04-3428 _ Royce Young, * * Appellant, * * Appeal from the United States v. * District Court for the * District of Minnesota. Pollock Engineering Group, Inc.; * Pollock Research and Design, Inc.; * Computech, a sole proprietorship; * and Lewis L. Deland, an individual, * * Appellees. * _ Submitted: May 9, 2005 Filed: November 15, 2005 _ Before BENTON, LAY, and FAGG, Circuit Judges. _ BENTON, Circuit Judge. Royce Dale Young was injured wh
More
                     United States Court of Appeals
                           FOR THE EIGHTH CIRCUIT
                                    ___________

                                    No. 04-3428
                                    ___________

Royce Young,                           *
                                       *
            Appellant,                 *
                                       * Appeal from the United States
      v.                               * District Court for the
                                       * District of Minnesota.
Pollock Engineering Group, Inc.;       *
Pollock Research and Design, Inc.;     *
Computech, a sole proprietorship;      *
and Lewis L. Deland, an individual,    *
                                       *
            Appellees.                 *
                                  ___________

                              Submitted: May 9, 2005
                                 Filed: November 15, 2005
                                  ___________

Before BENTON, LAY, and FAGG, Circuit Judges.
                           ___________

BENTON, Circuit Judge.

       Royce Dale Young was injured while working as a "die man" at Alexandria
Extrusion Company (AEC). A die man loads dies into a die changer, here
manufactured by Pollock Engineering Group, Inc. A co-employee operates the die
changer from a control panel, which was provided by Computech about three years
after the installation of the die changer. Once activated, the die changer inserts dies
into an extrusion press.
       On the night of the injury, Young was loading dies into the die changer while
Robbie Joe Betterman operated the control panel. Not intending any harm, Betterman
activated the die changer, severely injuring Young's left hand. AEC later installed a
"barrier guard" or barrier fence around the die changer.1


        Invoking diversity jurisdiction, Young sued Pollock for negligence and strict
liability in defectively designing the die changer. Young also sued for failure to warn
of the dangers associated with the product. The district court granted summary
judgment to Pollock, Computech, and Lewis L. Deland on all counts. On appeal,
Young attacks the judgment only as to Pollock. This court affirms the summary
judgment on the failure-to-warn claim, but reverses as to the defective-design claims.


                                          I.


       This court reviews de novo a grant of summary judgment, applying the same
standard as the district court. See Essco Geometric v. Harvard Indus., 
46 F.3d 718
,
729 (8th Cir. 1995). Summary judgment is affirmed where there is no genuine issue
of material fact, and judgment is appropriate as a matter of law. See 
id., citing Fed.
R. Civ. P. 56(c). This court construes the facts in favor of the non-moving party. See
RSBI Aerospace, Inc. v. Affiliated FM Ins. Co., 
49 F.3d 399
, 401 (8th Cir. 1995),
citing Anderson v. Liberty Lobby, Inc., 
477 U.S. 242
, 255 (1986).




      1
       The Appellant's Brief violates FED. R. APP. P. 28(a)(7), as it does not cite the
Appendix, and rarely references the record. Although this court is not required to
search the record, the violations in this case do not prevent review of the arguments
presented. See Lucas v. Lucas, 
946 F.2d 1318
, 1325 (8th Cir. 1991).
                                         -2-
       A plaintiff asserting defective design under Minnesota law must establish that
the defendant's product "was in a defective condition unreasonably dangerous for its
intended use." See Bilotta v. Kelley Co., 
346 N.W.2d 616
, 623 n.3 (Minn. 1984) (en
banc), citing Lee v. Crookston Coca-Cola Bottling Co., 
188 N.W.2d 426
, 432 (Minn.
1971). To determine whether there is enough evidence to submit the claim to a jury,
the court must balance "the likelihood of harm, and the gravity of harm if it happens,
against the burden of the precaution which would be effective to avoid the harm."
See 
Bilotta, 346 N.W.2d at 621
, quoting Holm v. Sponco, 
324 N.W.2d 207
, 212
(Minn. 1982) (en banc). See generally Trost v. Trek Bicycle Corp., 
162 F.3d 1004
,
1009 (8th Cir. 1998) (summarizing Minnesota law).


       An important factor in this balancing test is the availability of a feasible, safer
alternative design. See Kallio v. Ford Motor Co., 
407 N.W.2d 92
, 96 (Minn. 1987)
(en banc). Only in rare cases do defective-design claims succeed without showing
a safer design. See 
id. at 97
n.8. "Conceivably, rare cases may exist where the
product may be judged unreasonably dangerous because it should be removed from
the market rather than be redesigned." 
Id. In Minnesota,
"successful plaintiffs,
almost without fail, introduce evidence of an alternative safer design." 
Id. at 95
n.6
(citing cases).


       Young relies on the affidavits of two expert witnesses, both mechanical
engineers. Tarald O. Kvalseth, Ph.D., states that a number of feasible, safer designs
could have prevented Young's injuries. As an example, Pollock could have installed
a barrier guard like the one installed after Young's injuries. Dr. Kvalseth states that
the barrier guard could be an effective safety device when used with an "interlock
switch" that disables the die changer while the gate to the barrier guard is open. J.
Kenneth Blundell, Ph.D., agrees that an alternative design could have prevented
Young's injuries. Like Dr. Kvalseth, he proposes a barrier guard with an interlock
switch.

                                           -3-
    Although acknowledging the experts' opinions, the district court granted
summary judgment on the defective-design claims. The district court holds:


      [Young] does not contest that his proposed safety enhancements are
      external work area modifications available for purchase "off the shelf,"
      rather than mechanisms incorporated into the design of the die changer
      or "permanently attached to" the product. Huber v. Niagra Mach. &
      Tool Works, 
430 N.W.2d 465
, 466 (Minn. 1988) (en banc). This fact
      readily distinguishes the instant case from that relied on by [Young], in
      which the court found a manufacturer could be liable for defective
      design based upon exclusion of an integral safety component from some
      of its models. 
Bilotta, 346 N.W.2d at 622
, 624-25. Young does not
      suggest or reference an alternative die changer design that includes a
      safety device, and cites no authority for his proposition that the failure
      to recommend external safeguards made by different manufacturers can
      constitute a defect in design. Accordingly, his claim is appropriately
      one of failure to warn and it will be addressed as such. Summary
      judgment for Pollock is thus warranted on the issue of defective design.

      The district court's reasoning is erroneous in two respects. First, Young did not
concede that his proposed modifications should not have been incorporated into the
design of the die changer. In written suggestions Young argued: "Plaintiff's experts
have identified other feasible safety devices that could have been used to safeguard
the Die Changer, and which should have been incorporated by Pollock in its original
design of the product." (emphasis added). Young restated his position during oral
argument in the district court.


       Young's position is supported by the affidavits of his expert witnesses, who
advocate alternative designs of the die changer itself. In the same sentence where Dr.
Kvalseth says that the proposed safety modifications are available "off the shelf," he
also states that Pollock should have incorporated them into the die-changer design.
Dr. Blundell agrees in his affidavit and attached report.

                                         -4-
      Pollock counters that during his deposition, Dr. Kvalseth agreed: he was not
proposing modifications to the functioning or configuration of the "die slide itself";
and, his proposed modifications were not "physically attached" to the die slide.
However, Dr. Kvalseth later said in his deposition that industry standards do not
permit a manufacturer to "design an extrusion press and just leave out guards." Dr.
Kvalseth's deposition, interpreted in Young's favor, says that the die changer itself
was unreasonably dangerous.


       Dr. Blundell's deposition, interpreted in Young's favor, is to the same effect.
Dr. Blundell, after opining that the manufacturer should provide safeguards, testified
that Pollock should have examined the die changer for pinch-point hazards and
identified the lack of safeguards.


       Pollock argues that the experts' testimony is inadmissible because they failed
to take measurements to determine the feasibility of the safety modifications they
propose. Testimony may be excluded if an expert fails to explain how a proposed
safety modification would protect the machine's operators without compromising the
machine's utility. See Unrein v. Timesavers, Inc., 
394 F.3d 1008
, 1012 (8th Cir.
2005) (holding that the district court properly excluded Dr. Kvalseth's testimony
regarding an industrial sander). However, in this case the experts did not need to
conduct a detailed feasibility study of the barrier guard because AEC had installed the
barrier guard and used it successfully with the die changer. Both experts explained
that the barrier guard—used with a simple switch to cut the power to the die changer
while the gate of the barrier guard is open—would be an effective safety device. In
sum, Young presented admissible evidence supporting his allegation that the die
changer itself was defective and unreasonably dangerous. See 
Anderson, 477 U.S. at 256
.




                                         -5-
       Second, the district court erroneously concluded that Minnesota law recognizes
a distinction between external work area modifications and integral safeguards, in
design defect cases. For that conclusion, the district court cites Huber, which was not
a defective design case. Rather, it held that the manufacturer of a component foot
switch with a "permanently attached" safety device did not have the duty to warn
users that the safety device should not be removed. See 
Huber, 430 N.W.2d at 466
.


       The closest Minnesota authority is Harmon Contract Glazing, Inc. v.
Libby-Owens-Ford Co., 
493 N.W.2d 146
, 149 (Minn. Ct. App. 1992), which held
that the plaintiff could not recover for defective design of a shipping brace that
secured glass panes during transit because the brace was not an "integral part of the
product itself." 
Id. Unlike the
brace in Harmon, the barrier guard Young proposes
would have been integrated into the product during its normal use. See Cerepak v.
Revlon, Inc., 
200 N.W.2d 33
(Minn. 1972) (deodorant bottle); Holkestad v.
Coca-Cola Bottling Co. of Minn., Inc., 
180 N.W.2d 860
(Minn. 1970) (en banc)
(soft-drink bottle).


        Other than these cases, the distinction – "external" versus "integral" or
"internal" – does not appear in the Minnesota cases. In deciding whether summary
judgment is appropriate as a matter of law, this court therefore follows the leading
case, Bilotta, where the Minnesota Supreme Court states that allowing manufacturers
to sell products without adequate safety devices would "permit an entire industry to
market unreasonably dangerous 'stripped down' devices." 
Bilotta, 346 N.W.2d at 624
. The district court's holding – that Pollock could be liable only for modifications
that would have been permanently attached to the die changer – "would circumvent
the general duty of the manufacturer to provide a reasonably safe design for its
products." See 
Id. at 624-625.



                                         -6-
       In footnote three of its order, the district court states that its conclusion "is
bolstered by the American National Standards Institute's assignment to the employer
of the obligation to provide 'adequate guards, awareness devices, presence-sensing
devices, and/or appropriate controls to provide proper protection to operating
personnel.,'" quoting American National Standard for Machine Tools - Horizontal
Hydraulic Extrusion Presses - Safety Requirements for Construction, Care, and
Use, B11.17 § 5.1 (1982) (emphasis in original court order). The district court
reasoned that the manufacturer does not have to include such safety devices in the
product design. This reasoning is contrary to Minnesota law. Although the employer
is generally responsible for ensuring worker safety, "a manufacturer may not delegate
its duty to design a reasonably safe product." See 
Bilotta, 346 N.W.2d at 624
; Gorath
v. Rockwell Int'l, Inc., 
441 N.W.2d 128
, 133 (Minn. Ct. App. 1989).


        Further – to the extent they are relevant – the district court reads the ANSI
standards too narrowly. True, under section 5 of the standards, employers are
responsible to provide certain safeguards. See American National Standard B11.17
§ 5.1. Equally relevant is section 3, the ANSI standard entitled "Construction and
Modification." 
Id. § 3.
In contrast to section 5, section 3 describes the responsibility
of extrusion press manufacturers. The explanatory notes to section 3 identify certain
hazards associated with moving parts, including "pinch points between moving and
stationary press components, such as . . . the areas where die carriers . . . are shifted
into or out of the press." 
Id. § E3.2.1.
The explanatory notes to section 3 state: "For
those areas requiring access for normal operation, awareness devices, presence
sensing devices, interlocked guards, or two-hand controls are some of the safeguards
that can be used to satisfy the requirements of Section 3." 
Id. As Dr.
Blundell
testified, the ANSI standards make both the employer and the manufacturer
responsible for safety. In sum, the ANSI standards do not bolster the district court's
conclusion that the employer alone was responsible to provide the safeguards Young's
experts proposed.


                                          -7-
       This court also rejects Pollock's related argument that OSHA regulations
relieve it of liability for designing a defective product. The regulations do establish
safety requirements for employers whose employees use mechanical power presses.
See 29 C.F.R. § 1910.217. However, OSHA regulations generally "pertain only to
employers' conduct," and do not purport to define the obligations of manufacturers.
See Minichello v. U.S. Indus., Inc., 
756 F.2d 26
, 29 (6th Cir. 1985), citing
McKinnon v. Skil Corp., 
638 F.2d 270
, 275 (1st Cir. 1981).


      In Minnesota, the jury ultimately decides whether the die changer was
unreasonably dangerous. See 4A Minnesota Practice, CIVJIG 75.20 (4th ed. 1999).
This court concludes that Young has presented sufficient evidence of a defective
design to survive summary judgment. See Bastow v. General Motors Corp., 
844 F.2d 506
, 510 (8th Cir. 1988) ("[I]t is not for us to decide whether defendants' or plaintiff's
evidence is more persuasive. It is for the jury.")


                                           II.


      The district court concluded that Pollock had no duty to warn Young about the
potential hazards associated with the die changer because such hazards were open and
obvious. The court correctly noted that Young conceded that the pinch-point hazard
was obvious and that he had been trained in proper use of the die changer.


       Young counters that the danger Pollock should have brought to his attention
was not the pinch point, but the possibility that the die changer could be unexpectedly
activated. However, Young conceded in his deposition that he did not know of any
warnings Pollock could have given that would have prevented the accident. The
district court correctly concluded that Young was aware of the potential hazards and
that Pollock had no duty to warn him. See Dahlbeck v. DICO Co., 
355 N.W.2d 157
,

                                           -8-
163 (Minn. Ct. App. 1984) ("[A] manufacturer has no duty to warn when the dangers
of a product are within the professional knowledge of the user."), quoting Strong v.
E.I. DuPont de Nemours Co., 
667 F.2d 682
, 687 (8th Cir. 1981).2


                                          III.


      The judgment as to the failure-to-warn claim is affirmed. The judgment is
reversed as to Young's claims for defective design, and the case remanded.




LAY, Circuit Judge, concurring and dissenting.


      I dissent from the majority’s opinion that Pollock maintained no duty to warn
Young of dangers associated with the unexpected activation of the die changer. In
doing so, I concur with the majority opinion that the district court erred by dismissing
Young’s defective design claim under Minnesota law.




      2
        For the purpose of the claims for defective design discussed in Part I, the
obviousness of the danger created by the product is not a complete bar to recovery,
but may be considered in the balancing test and may also be relevant to whether the
plaintiff exercised reasonable care in using the product. See 
Holm, 324 N.W.2d at 211-213
, rejecting Halvorson v. American Hoist & Derrick Co., 
240 N.W.2d 303
,
305 (Minn. 1976).
                                          -9-
                               FAILURE TO WARN


       To prevail against a manufacturer on a failure to warn claim, a plaintiff must
prove: (1) that the manufacturer failed to warn of a foreseeable danger associated
with the use of its product; and (2) causation. Germann v. F.L. Smithe Mach. Co.,
395 N.W.2d 922
, 924 (Minn. 1986); Drager by Gutzman v. Aluminum Indus. Corp.,
495 N.W.2d 879
, 888 (Minn. Ct. App. 1993). It is a question of law whether the
danger resulting from the alleged failure to warn was reasonably foreseeable.
Germann, 395 N.W.2d at 924
. If the connection between the event causing the
damage and the failure to act is too remote to impose liability as a matter of public
policy, then the manufacturer maintains no duty to inform of the alleged danger. 
Id. Similarly, if
the danger alleged is “obvious to anyone using the product,” then no duty
to warn arises. Mix v. MTD Prods., Inc., 
393 N.W.2d 18
, 19 (Minn. Ct. App. 1986).
When assessing the obviousness of the risk of harm, we must determine whether the
plaintiff was aware of the specific danger posed by the device. See Indep. Sch. Dist.
No. 14 v. AMPRO Corp., 
361 N.W.2d 138
, 143 (Minn. Ct. App. 1985) (stating that
a duty to warn exists where the danger involved is “different, more serious, and more
unexpected” than an obvious risk).


      In this case, the facts mandate the conclusion that the relationship between
Young’s injury and Pollock’s failure to warn that the die changer might be
unexpectedly activated is not too remote to impose liability. Absent a warning, it is
foreseeable that Young, as a line employee responsible for the regular operation and
replacement of the die changer, might, in a moment of diversion, keep his hand near,
next to, or inside the die changer after its deactivation under the belief that the
changer was properly turned off. Moreover, there is no record evidence to support
the conclusion that the danger of unexpected activation was obvious, or that Young
knew of the specific threat that the die changer could be unexpectedly activated.



                                         -10-
       The district court’s reliance on 29 C.F.R. § 1910.217(c)(1)(i),3 which places the
burden on the employer to provide and insure the proper usage of “point of operation
guards” and “point of operation devices” to relieve Pollock of its duty to warn that
the die changer could be unexpectedly activated, is misplaced. In its analysis, the
district court incorrectly concluded that Pollock’s failure to warn of the specific
danger of unexpected activation implicates the “external safety devices and controls”
referenced in § 1910.217(c)(1)(i). Young v. Pollock Eng’g, No. 02-4377, 2004 U.S.
Dist. LEXIS 14378, at *12 (D. Minn. July 28, 2004). Under § 1910.217(c)(1)(i),4 the
duty to safeguard points of operation through the use of guards and devices is the
responsibility of the employer. 
Id. Point of
operation guards, for their part, “consist of barriers erected to prevent
an operator from placing any part of his body in the danger zone of the press.” Huber
v. Niagara Mach. & Tool Works, 
430 N.W.2d 465
, 468 (Minn. 1988) (citing 29
C.F.R. § 1910.217(c)(1)(i)). By contrast, “[p]oint of operation ‘devices’ protect an
operator by forcing [the operator] to manually activate switch controls located away
from the danger zone before the press will operate, thus preventing [the operator]
from placing parts of his body in the danger zone of the press while it is running.”


      3
        The district court also cited industry-wide safety standards promulgated by the
American National Standards Institute (“ANSI”) to relieve Pollock of its duty to warn
that the die changer could be unexpectedly activated. However, no Minnesota case
has employed ANSI standards to define the scope of a product manufacturer’s duty
to warn of foreseeable dangers associated with the use of its product. See Westbrock
v. Marshalltown Mfg. Co., 
473 N.W.2d 352
, 358 (Minn. Ct. App. 1991) (noting that
the trial court, correctly, “did not substitute ANSI and OSHA standards for case law
duty analysis”).
      4
        At least one Minnesota case has applied 29 C.F.R. § 1910.217(c)(1)(i) in the
context of a manufacturer’s duty to warn of foreseeable dangers associated with the
use of a component product. See Huber v. Niagra Mach. & Tool Works, 
430 N.W.2d 465
, 468 (Minn. 1988).
                                         -11-

Id. Given this
framework, an oral or written warning indicating that the die changer
could be unexpectedly activated is neither a barrier erected to prevent bodily harm nor
a device that forces the operator to manually activate switch controls located away
from the zone of danger. As a result, Pollock’s duty to warn of the potential for
unexpected activation cannot be delegated to Young’s employer under
§ 1910.217(c)(1)(i). As such, Pollock maintained a duty to warn Young of this risk.


                                    CAUSATION


       Turning to the issue of causation, genuine issues of material fact exist
regarding whether Pollock’s failure to warn of the potential for unexpected activation
caused Young’s injury. In Minnesota, the question of causation is normally left for
the jury. See, e.g., Ponticas v. K.M.S. Invs., 
331 N.W.2d 907
, 915 (Minn. 1983).
Only where there is “no room for an honest difference of opinion among reasonable
people” may courts take an issue of causation away from the finder of fact. Gum v.
Medcalf Orthopaedic Appliance Co., 
380 N.W.2d 916
, 921 (Minn. Ct. App. 1986)
(quoting Johnson v. Evanski, 
22 N.W.2d 213
, 215 (Minn. 1946)). This case presents
room for honest difference of opinion concerning the cause of Young’s injury.


      Young was not informed by Pollock of the possibility that the die changer
might be unexpectedly activated even though he was the worker assigned to regularly
operate, change, and replace the device. A jury might reasonably infer that Young
would have exercised greater caution with the die changer, especially considering his
frequent contact with the device, if he was informed of the possibility that the changer
could be suddenly activated.5


      5
        Many jurisdictions have adopted the principle that if a plaintiff is not warned
of a particular risk, a rebuttable presumption arises that a proper warning would have
been heeded, thereby establishing causation. See, e.g., Golonka v. Gen. Motors
                                         -12-
       The district court, however, found that Young did not establish causation
because a failure to warn “ is not the proximate cause of injury if the user is aware of
the danger posed by the device at issue.” Young, 
2004 U.S. Dist. LEXIS 14378
, at
*13 (citing Holowaty v. McDonald’s Corp., 
10 F. Supp. 2d 1078
, 1085 (D. Minn.
1998)). However, this analysis fails because, once again, there is no record evidence
to demonstrate that Young knew the die changer could be unexpectedly activated, or
that he was warned of the possibility for unexpected activation.


       The district court concluded, noting that the “effect of a warning on [Young’s]
conduct is particularly questionable in light of the fact that he had performed this task
many times without incident . . . .” 
Id. at *14.
Yet the determination as to how
Young may have acted if warned that the die changer could be unexpectedly activated
is the very type of fact-intensive inquiry best left for a jury. Therefore, the district
court erred when it found there was no genuine issue of material fact on the issue of
causation.


                 SOPHISTICATED INTERMEDIARY DEFENSE


       Pollock asserts that even if it maintained a duty to warn Young, this duty was
relieved by Alexandria Extrusion Company’s (“AEC”) status as a sophisticated
intermediary. Courts typically apply the sophisticated intermediary defense when:
(1) the employer maintained full knowledge of the range of dangers equal to that of



Corp., 
65 P.3d 956
, 967-72 (Ariz. Ct. App. 2003); Coward v. Owens-Corning
Fiberglas Corp., 
729 A.2d 614
, 621-22 (Pa. Super. Ct. 1999); Coffman v. Keene
Corp., 
628 A.2d 710
, 716-21 (N.J. 1993); House v. Armour of America, Inc., 
929 P.2d 340
, 347 (Utah 1996). But see Tuttle v. Lorillard Tobacco Co., 
377 F.3d 917
, 925
(8th Cir. 2004) (stating that, in its view, the court did not think Minnesota “would
adopt the rebuttable presumption” in the case presented).
                                          -13-
the manufacturer; or (2) the manufacturer made the employer knowledgeable by
providing adequate warnings and safety instructions to the employer. Gray v. Badger
Mining Corp., 
676 N.W.2d 268
, 277-78 (Minn. 2004). When applicable, the
sophisticated intermediary defense permits a manufacturer or distributor to discharge
its duty to warn of foreseeable dangers related to the use of its product if the
manufacturer or distributor exercised reasonable care in relying upon the intermediary
to give a warning to the end user. See 
id. at 278.

       Young notes, however, that no Minnesota court has extended the sophisticated
intermediary defense to employer/employee relationships and, as a result, the defense
has been implicitly restricted in Minnesota. See 
id. (noting that
some courts,
including the Fifth Circuit and a federal district court in Minnesota, “have been
reluctant to extend the rationale of the sophisticated user defense to sophisticated
intermediaries”).


       Given the current state of the law, I agree. The Minnesota Supreme Court’s
recent reluctance to define the full applicability or scope of the sophisticated
intermediary defense, 
id. at 278-79,
coupled with the infrequency with which the
defense is applied by other jurisdictions in the employer/employee context, suggests
that the sophisticated intermediary defense does not apply to this case.


       Even if the defense was applicable, Pollock has failed to show that it exercised
reasonable care in relying upon the AEC to give a warning to end users. Pollock is
able to reference no record evidence that Pollock actually warned AEC of the danger
for unexpected activation, or that it acted in a manner reasonably calculated to assure
that AEC might be made aware of the danger that the die changer could be
unexpectedly activated. See 
id. at 278
(stating that, when determining if the supplier
exercised reasonable care, courts look to “whether the supplier acted in a manner


                                         -14-
reasonably calculated to assure [] that the necessary information would be passed on
to the ultimate handlers of the product”).


      Young’s resulting injury was a foreseeable consequence of Pollock’s failure
to warn about the risk of, and potential for, unexpected activation. Moreover,
causation was certainly a jury question and should not be ruled upon under summary
judgment. Accordingly, I would reverse on both the failure to warn and defective
design claims and remand for trial.


                       _____________________________




                                       -15-

Source:  CourtListener