Elawyers Elawyers
Ohio| Change
Find Similar Cases by Filters
You can browse Case Laws by Courts, or by your need.
Find 49 similar cases
HY KOM DEVELOPMENT COMPANY vs. DEPARTMENT OF ENVIRONMENTAL REGULATION, 89-002957 (1989)
Division of Administrative Hearings, Florida Number: 89-002957 Latest Update: Oct. 12, 1992

Findings Of Fact On or about December 28, 1987 Hy Kom filed with the Department an application for a permit to construct a .0126 MGD Advanced Waste Water Treatment Plant on Emerson Point, Snead Island in Manatee County. The proposed waste water treatment plant would discharge effluent into the waters of Terra Ceia Bay in Manatee County. The proposed waste water treatment plant would discharge effluent into the waters of Tampa Bay in Manatee County. The proposed waste water treatment plant would discharge effluent into the waters of Manatee River in Manatee County. The waters of Terra Ceia Bay have been designated Outstanding Florida Waters (OFW) by the Department. On or about April 27, 1989 the Department issued a Notice of Permit Denial concerning Hy Kom's permit application. The parties stipulate the Intervenor, Manasota-88, has standing to intervene as a party Respondent and to object to the issuance of the permit. Petitioner's evidence can best be summarized by what was not submitted. First, the expert witness called to identify the application had not prepared any part of the application or verified any of the studies presented therein. Similarly Petitioner's expert on the proposed treatment plant did not testify that Petitioner was committed to using this plant, or that the construction of the plant and the operation of the plant would comply with statutory and rule requirements. The only witness called by Petitioner to testify to the effect the discharge from the proposed advanced waste water treatment plant would have on the receiving waters was also Respondent's expert; and this witness testified that the effluent discharge from this proposed plant would have an adverse effect on the receiving waters, would seriously degrade the receiving waters as a nursery habitat for both crustacea and fishes endemic to the area, and that no reasonable assurances that this would not happen were ever presented by the Petitioner. This witness further testified that no discharge into these receiving waters would be acceptable not only because of the nitrogen level (which was the most significant reason for denying the permit) but also because even a discharge of absolutely pure water would upset the salinity of the receiving waters at the critical time the receiving waters act as a marine nursery.

Recommendation It is RECOMMENDED that a Final Order be entered denying the application of Hy Kom Development Company, for a permit to construct and operate an advanced waste water treatment facility at Emerson Point, Snead Island, Manatee County, Florida. DONE and ORDERED this _15th_ day of September, 1992 in Tallahassee, Leon County, Florida. COPIES FURNISHED: JAMES W. STARNS ESQ 501 GOODLETTE RD SUITE D-100-24 NAPLES FL 33940 W DOUGLAS BEASON ESQ ASST GENERAL COUNSEL K. N. AYERS Hearing Officer Division of Administrative Hearings The DeSoto Building 1230 Apalachee Parkway Tallahassee, Florida 32399-1550 (904) 488-9675 Filed with the Clerk of the Division of Administrative Hearings this _15th_ day of September, 1992. DEPT OF ENVIRONMENTAL REGULATION 2600 BLAIRSTONE RD TALLAHASSEE FL 32399 2400 THOMAS W REESE ESQ 123 EIGHTH ST N ST PETERSBURG FL 33701 DANIEL H THOMPSON ESQ GENERAL COUNSEL DEPT OF ENVIRONMENTAL REGULATION 2600 BLAIRSTONE RD TALLAHASSEE FL 32399 2400 CAROL BROWNER SECRETARY DEPT OF ENVIRONMENTAL REGULATION 2600 BLAIRSTONE RD TALLAHASSEE FL 32399 2400

Florida Laws (1) 403.086
# 1
LANIGER ENTERPRISES OF AMERICA, INC. vs DEPARTMENT OF ENVIRONMENTAL PROTECTION, 05-001599 (2005)
Division of Administrative Hearings, Florida Filed:Stuart, Florida May 04, 2005 Number: 05-001599 Latest Update: Feb. 22, 2007

The Issue The issue in this case is whether Respondent Laniger Enterprises of America, Inc. (Laniger), is entitled to the renewal of its domestic wastewater facility permit that was denied by Petitioner Department of Environmental Protection (Department).

Findings Of Fact The Parties The Department is the administrative agency of the State of Florida having the power and duty to protect Florida's air and water resources and to administer and enforce the provisions of Chapter 403, Florida Statutes (2005),1 and the rules promulgated in Florida Administrative Code Title 62. Laniger is a Florida corporation that owns and operates the WWTP that is the subject of this case, located at 1662 Northeast Dixie Highway, Jensen Beach, Martin County, Florida. The WWTP is referred to in the Department permit documents as the Beacon 21 WWTP. The WWTP Laniger acquired the WWTP in 1988 in a foreclosure action. At that time, the WWTP was in a "dilapidated" condition and was operating under a consent order with the Department. After acquiring the WWTP, Laniger brought it into compliance with the Department's requirements. Laniger's WWTP is commonly referred to as a "package plant."2 The WWTP's treatment processes are extended aeration, chlorination, and effluent disposal to percolation ponds. The WWTP does not have a direct discharge to surface water. It was permitted to treat 99,000 gallons per day (gpd) of wastewater. Its average daily flow during the past year was about 56,000 gallons. The east side of the WWTP site is adjacent to Warner Creek. On the north side of the WWTP site, an earthen berm separates the WWTP's percolation ponds from a drainage ditch that connects to Warner Creek. Warner Creek is a tributary to the St. Lucie River. The St. Lucie River is part of the Indian River Lagoon System. The Indian River Lagoon Act In 1989, the St. Johns River Water Management District and the South Florida Water Management District jointly produced a Surface Water Improvement and Management (SWIM) Plan for the Indian River Lagoon System ("the lagoon system"). For the purpose of the planning effort, the lagoon system was defined as composed of Mosquito Lagoon, Indian River Lagoon, and Banana River Lagoon. It extends from Ponce de Leon Inlet in Volusia County to Jupiter Inlet in Palm Beach County, a distance of 155 miles. The SWIM Plan identified high levels of nutrients as a major problem affecting water quality in the lagoon system. Domestic wastewater was identified as the major source of the nutrients. The SWIM Plan designated 12 problem areas within the lagoon system and targeted these areas for "research, restoration and conservation projects under the SWIM programs." Department Exhibit 2 at 11-13. Neither Warner Creek nor the area of the St. Lucie River that Warner Creeks flows into is within any of the 12 problem areas identified in the SWIM Plan. With regard to package plants, the SWIM Plan stated: There are numerous, privately operated, "package" domestic WWTPs which discharge indirectly or directly to the lagoon. These facilities are a continual threat to water quality because of intermittent treatment process failure, seepage to the lagoon from effluent containment areas, or overflow to the lagoon during storm events. Additionally, because of the large number of "package" plants and the lack of enforcement staff, these facilities are not inspected or monitored as regularly as they should be. Where possible, such plants should be phased out and replaced with centralized sewage collection and treatment facilities. Department Exhibit 2 at 64. In 1990, the Legislature passed the Indian River Lagoon Act, Chapter 90-262, Laws of Florida. Section 1 of the Act defined the Indian River Lagoon System as including the same water bodies as described in the SWIM Plan, and their tributaries. Section 4 of the Act provided: Before July 1, 1991, the Department of Environmental Regulation shall identify areas served by package sewage treatment plants which are considered a threat to the water quality of the Indian River Lagoon System. In response to this legislative directive, the Department issued a report in July 1991, entitled "Indian River Lagoon System: Water Quality Threats from Package Wastewater Treatment Plants." The 1991 report found 322 package plants operating within the lagoon system and identified 155 plants as threats to water quality. The 1991 report described the criteria the Department used to determine which package plants were threats: Facilities that have direct discharges to the system were considered threats. Facilities with percolation ponds, absorption fields, or other sub-surface disposal; systems located within 100 feet of the shoreline or within 100 feet of any canal or drainage ditch that discharges or may discharge to the lagoon system during wet periods were considered threats. * * * Facilities with percolation ponds, absorption fields, or other sub-surface disposal systems located more than 100 feet from surface water bodies in the system were evaluated case-by-case based on [operating history, inspection reports, level of treatment, and facility reliability]. Laniger's package plant was listed in the 1991 report as a threat to the water quality of the lagoon system because it was within 100 feet of Warner Creek and the drainage ditch that connects to Warner Creek. Laniger's WWTP was not determined to be a threat based on its wastewater treatment performance. There was no evidence presented that Laniger's WWTP had ever had intermittent treatment process failure, seepage to the lagoon system from effluent containment areas, or overflow during storm events. Those were the concerns related to package plants that were described in the SWIM Plan and the Department's 1991 report. Laniger's WWTP was not determined to be a threat based on evidence that it was causing or contributing to excess nutrients in Warner Creek or in that part of the St. Lucie River nearest to Laniger's WWTP. No evidence was presented that there are excess nutrients in Warner Creek or in that part of the St. Lucie River nearest to Laniger's WWTP. The Department's 1991 report concluded that the solution for package plants threats was to eliminate the package plants and connect their wastewater flow to centralized sewage collection and treatment facilities. To date, over 90 of the 155 package plants identified in the Department's 1991 report as threats to the water quality of the lagoon system have been connected to centralized sewage collection and treatment systems. The 1999 Permit and Administrative Order On August 26, 1999, the Department issued Domestic Wastewater Facility Permit No. FLA013879 to Laniger for the operation of its WWTP. Attached to and incorporated into Laniger's 1999 permit was Administrative Order No. AO 99-008- DW43SED. The administrative order indicates it was issued pursuant to Section 403.088(2)(f), Florida Statutes. That statute pertains to discharges that "will not meet permit conditions or applicable statutes and rules" and requires that the permit for such a discharge be accompanied by an order establishing a schedule for achieving compliance. The administrative order contains a finding that the Beacon 21 WWTP is a threat to the water quality of the lagoon system and that the WWTP "has not provided reasonable assurance . . . that operation of the facility will not cause pollution in contravention of chapter 403, F.S., and Chapter 62-610.850 of the Florida Administrative Code." The cited rule provides that "land application projects shall not cause or contribute to violations of water quality standards in surface waters." The administrative order required Laniger to connect its WWTP to a centralized wastewater collection and treatment [facility] "within 150 days of its availability . . . or provide reasonable assurance in accordance with Chapter 620.320(1) of the Florida Administrative Code that continued operation of the wastewater facility is not a threat to the water quality of the Indian River Lagoon System." As a result of an unrelated enforcement action taken by the Department against Martin County, and in lieu of a monetary penalty, Martin County agreed to extend a force main from its centralized sewage collection and treatment facility so that the Laniger WWTP could be connected. The extension of the force main was completed in April 2003. On April 10, 2003, the Department notified Laniger by letter that a centralized wastewater collection and treatment system "is now available for the connection of Beacon 21." In the notification letter, the Department reminded Laniger of the requirement of the administrative order to connect within 150 days of availability. On May 9, 2003, Laniger's attorney responded, stating that the administrative order allowed Laniger, as an alternative to connecting to the centralized wastewater collection and treatment system, to provide reasonable assurance that the WWTP was not a threat to the water quality of the lagoon system, and Laniger had provided such reasonable assurance. Laniger's attorney also stated, "due to the location of Martin County's wastewater facilities, such facilities are not available as that term is defined in the [administrative] order." On September 29, 2003, the Department issued a warning letter to Laniger for failure to connect to the Martin County force main and for not providing reasonable assurance that the WWTP will not cause pollution in contravention of Chapter 403, Florida Statutes. The Department took no further formal action until it issued the NOV in August 2005. Laniger's challenge of the NOV was consolidated with this permit case. The Permit Renewal Application In an "enforcement meeting" between Laniger and the Department prior to the expiration of 1999 permit, the Department told Laniger that it would not renew Laniger's WWTP permit. Later, when Laniger filed its permit renewal application, the Department offered to send the application back so Laniger would not "waste" the filing fee, because the Department knew it was not going to approve the application. Laniger submitted its permit renewal application to the Department on February 15, 2005. The Department considered Laniger's permit application to be complete, but proceeded to prepare the Notice of Denial without any technical review of the application. The Department denied the application on April 6, 2005. The Department's Notice of Permit Denial stated that the permit was denied because Laniger had not connected to the available centralized wastewater collection and treatment system nor provided reasonable assurance that the WWTP "is not impacting water quality within the Indian River Lagoon System." The record evidence showed that the "reasonable assurance" that would have been necessary to satisfy the Department was more than the reasonable assurance the Department usually requires for package plants, and more than the Department would have required if Laniger's WWTP was 100 feet from Warner Creek. Competent substantial evidence was presented that Laniger's WWTP is capable of being operated in accordance with the statutes and rules of Department generally applicable to package wastewater treatment plants. Laniger's 1999 permit expired on August 25, 2004. Laniger has operated the plant continuously since the permit expired. Whether the Martin County Facility is Available As discussed below in the Conclusions of Law, it is concluded that the Department did not have authority to require Laniger to connect the WWTP to the Martin County force main or to require assurance beyond the reasonable assurance generally required for package treatment plants in order to obtain a permit. However, because considerable evidence and argument was directed to whether the force main was available, that issue will be addressed here. The Martin County force main was not extended to the boundary of the Laniger WWTP site. The force main terminates approximately 150 feet north of the Laniger WWTP site and is separated from the WWTP site by a railroad and railroad right-of-way. Laniger presented undisputed evidence that the cost to connect to the Martin County force main would be approximately $490,000 and that cost was prohibitively high, given the relatively small number of households served by the WWTP. The Laniger WWTP is subject to rate regulation by the Public Service Commission (PSC). Laniger presented evidence suggesting that connection to the Martin County force main would result in rates that would not be approved by the PSC. The evidence was speculative and not competent to support a finding regarding PSC action. The evidence does show, however, that PSC rate regulation was not a factor that the Department considered when it determined that the Martin County force main was available. There is no Department rule that defines when a centralized sewage collection and treatment facility is "available." The determination that the Martin County force main was available to Laniger was made informally by members of the Department's compliance staff in the Department's St. Lucie office. Mr. Thiel testified that he considered the force main to be available because it was "in close proximity" to Laniger's WWTP. However, Mr. Thiel admitted that there is a difference of opinion within DEP as to when a facility is available and reasonable persons could disagree about whether a facility was available. Mr. Thiel thought that the cost to connect is a factor to be considered in determining whether a facility is available, but another Department employee did not think cost should be considered. There was no evidence that the Department took into account Laniger's cost to connect in determining that the Martin County force main was available. The Department simply assumed that the Martin County force main was close enough to the Laniger WWTP site that the cost to Laniger would not be prohibitive. In addition, the Department was aware of other package plants that had connected to centralized sewage collection and treatment facilities that were the same distance or a greater from the package plant, and the Department did not hear from the owners of the package plants that the costs were prohibitive. Timothy Powell of the Department stated that force mains are usually made available by extending the force main so that it is "abutting the property as much as possible." He also stated that he assumed that Martin County would extend its force main under the railroad and to the boundary of the Laniger WWTP site after Laniger agreed to connect. However, there was no evidence to show that this is Martin County's intent, and the Department did not tell Laniger that Laniger did not have to connect to the force main unless Martin County brought the line to the boundary of the WWTP site. If the Department had authority to require Laniger to connect to the Martin County force main when it became available, and in the absence of any rule criteria to determine when a centralized sewage collection and treatment facility is available, the determination would have to be based on reasonableness. Reasonableness in this context must take into account the cost of the connection. Cost is the inherent reason that Laniger was not required to connect to the Martin County centralized sewage collection and treatment facility without regard to whether the facility was available. Laniger showed that the cost of connecting to the force main is unreasonably high due to the need to construct a line beneath the railroad. Therefore, Laniger proved by a preponderance of the evidence that the Martin County force main is not available.

Recommendation Based on the foregoing Findings of Fact and Conclusions of Law, it is RECOMMENDED that the Department of Environmental Protection enter a final order granting Laniger Enterprises of America, Inc., a renewal of its wastewater treatment plant operating permit. The permit should contain the same conditions as were contained in the 1999 permit, with the exception of those conditions derived from Administrative Order No. AO 99-008- DW43SED. DONE AND ENTERED this 19th day of September, 2006, in Tallahassee, Leon County, Florida. S BRAM D. E. CANTER Administrative Law Judge Division of Administrative Hearings The DeSoto Building 1230 Apalachee Parkway Tallahassee, Florida 32399-3060 (850) 488-9675 SUNCOM 278-9675 Fax Filing (850) 921-6847 www.doah.state.fl.us Filed with the Clerk of the Division of Administrative Hearings this 19th day of September, 2006.

Florida Laws (4) 120.569120.57403.087403.088
# 2
JAMES R. REGAN vs. DEPARTMENT OF ENVIRONMENTAL REGULATION, 89-001844 (1989)
Division of Administrative Hearings, Florida Number: 89-001844 Latest Update: Jan. 31, 1990

The Issue Whether the August 30, 1988 application of Petitioner James R. Regan for a permit to operate a wastewater (sewage) treatment facility should be granted in that Petitioner has provided reasonable assurances that the operation of the facility will not discharge, emit, or cause pollution in contravention of Department of Environmental Regulation standards or rules.

Findings Of Fact The sewage treatment plant that is the focus of this proceeding is "Weakley Bayou, Inc.," a corporation. The real property upon which it is located is owned by the wife of James R. Regan. Despite corporate status, Weakley Bayou, Inc. has been operated at the option and control of James R. Regan since its inception in the early 1970's. The permit application here at issue was made in Mr. Regan's name, and he has been treated as if he were the corporation throughout all stages of the permit process. Mr. Regan brought the Petition for Formal Hearing in his own name. He was also accepted as the qualified representative for himself and the corporation. "Weakley Bayou, Inc." is an aerobic gravity flow wastewater treatment plant located in Escambia County. In 1988 James R. Regan applied for a renewal of the operating permit for the facility. The Department of Environmental Regulation (DER) issued an Intent to Deny on December 16, 1988, based on agency perceptions derived from observations, monitoring of Petitioner- generated reports, and grab samples, that the facility did not meet the requirements set down in Rule 17-6 F.A.C. Specifically, the Intent to Deny focused on the following problems: A reclaimed water sample taken on December 6, 1988 revealed the facility was exceeding BOD5 (Biological Oxygen Demand) and TSS (Total Suspended Solids) limits in violation of specific condition number 17 of Permit Number D017-71682. The BOD5 was 232.8 mg/l and TSS was 1,430 mg/l. The same sampling showed the facility was exceeding 200/100 ml for fecal coliform in violation of specific condition number 17 of permit number D017-71682 and Rule 17- 6.180(1)(b)4.d., Florida Administrative Code. The fecal coliform was 79,000/100 ml. Ground water monitoring samples show the levels of nitrates in excess of 10 mg/l in well #l on two out of last four quarterly samples, which is in violation of Rule 17- 6.040(4)(q) paragraph 4.2, Florida Administrative Code. During the inspection on December 6, 1988, the sludge blanket in the clarifier was overflowing the weirs, solids had accumulated in the chlorine contact chamber and percolation ponds in violation of Rule 17- 6.110(3) and 17-6.180(2) (e) , Florida Administrative Code. Auxiliary electrical power is not provided as required by Rule 17-6.040(4) (c) and 17-6.110(3), Florida Administrative Code. The applicant was notified March 14, 1988, that emergency power would be required. During the period (1984-1988) that Petitioner's sewage treatment plant has been permitted by DER, it has been periodically inspected and the Petitioner's self-generated reports have been monitored. From time to time after inspections, Petitioner has been notified of pollution and contaminant hazards or violations pursuant to agency standards, which hazards or violations required corrections in order to retain his permit. Among these hazards and violations have been noted large sewage spills, overflows, poor equipment condition, and substandard plant operation. In most instances, Petitioner cooperated with DER and at least attempted to adjust the plant's operation to conform to the notifications. However, as of December 15, 1988, DER notified Petitioner of the following problems with the plant: sludge blanket in the clarifier overflowing the weir, solids accumulation in the chlorine contact chamber, solids accumulation in both percolation ponds, no auxiliary power on the site, and high levels of nitrates (6.9 ppm) in Monitoring well -1. DER's test of an effluent grab sample tested BOD at 232.8 mg/L and Total Suspended Solids (TSS) at 1430 mg/L. That is, samples taken by DER during an inspection indicated excessive levels of TSS, BOD, and fecal coliform, in violation of Chapter 403 F.S. and Chapter 17-6 F.A.C. Mr. Regan admitted that for approximately four years, broken and unrepaired pipes and fittings at his plant had caused sewage spills or overflows of approximately eight thousand gallons of sewage sludge. He contended that the surface enrichment around Monitoring Well #1 was caused by a separation of a two-inch PVC skimmer line which was corrected in March 1988. Although Mr. Regan established that the leak in the pipe had been repaired, the evidence does not permit a finding that this enrichment was solely from that source, that it will dissipate over a reasonable time, or that it has not polluted the ground water. 1/ Thus, there is no reasonable assurance that fixing the leak, by itself, protects the environment. Over a period of time, Petitioner's own groundwater monitoring reports showed excessive nitrate levels and these have worsened since late 1988, according to witness Ray Bradburn. Petitioner contended that a grab sample is not as accurate as a composite sampling. Although DER witnesses concur in this contention of Petitioner with regard to grab samples generally, and although one DER witness suggested that part of the December 1988 grab sample reading by itself would not cause him to deny the permit, no credible evidence disputes the accuracy of the December 6, 1988 grab sample as a grab sample.2/ Petitioner admitted that it was and continues to be his conscious management decision to keep the plant's auxiliary gasoline powered engine locked away from the plant site so as to discourage theft and vandalism, and so as to discourage childish curiosity which might expose Petitioner to liability. He was reluctant to secure the engine on the premises as a hedge against emergency shutdowns of the plant. Mr. Regan, upon advice of outside engineers, has attempted to correct many of the cited errors and omissions. However, notwithstanding the DER's express disapproval of such a method, Mr. Regan has instructed his plant operators to curtail the input of air from the plant's blower to the sewage at night so as to create a "belching" effect designed to clear out certain wastes and thereby attempt denitrification in the clarifier. DER witnesses did not explain in any detail why Regan's belching procedure was unacceptable except that addition of an expensive denitrification unit was preferable and constituted a "reasonable assurance," whereas Mr. Regan's method had not been demonstrated to be successful in the past. Mr. Regan, who bears the burden of proof in these proceedings, did not demonstrate that his "belching" system was a reasonable assurance of denitrification or offer expert witnesses to support such a theory. This sewage treatment plant is subject to a Notice of Violation which became final on September 21, 1989. 3/

Recommendation Upon the foregoing Findings of Fact and Conclusions of Law, it is RECOMMENDED that the Department of Environmental Regulation enter a Final Order denying the pending permit application. DONE and ENTERED this 31st day of January, 1990, at Tallahassee, Florida. ELLA JANE P. DAVIS, Hearing Officer Division of Administrative Hearings The DeSoto Building 1230 Apalachee Parkway Tallahassee, Florida 32399-1550 (904) 488-9675 Filed with the Clerk of the Division of Administrative Hearings this 31st day of January, 1990.

Florida Laws (1) 120.57
# 3
JAMES F. SEDER vs. DEPARTMENT OF HEALTH AND REHABILITATIVE SERVICES, 89-001626 (1989)
Division of Administrative Hearings, Florida Number: 89-001626 Latest Update: Jul. 06, 1989

The Issue Whether the Petitioner's request for variance should be granted.

Findings Of Fact Petitioner owns an undeveloped parcel of land in Palm Beach, County which is zoned industrial and on which he intends to construct a storage building to house and repair farm equipment. To provide sewage treatment at the site, Petitioner had designed an on site sewage disposal system and applied for a septic tank permit which was denied as was his variance request. The closest public sewage treatment plant to the property is over five miles from the site, and the closest private treatment is approximately three miles from the subject site. Petitioner has no easement to either site if capacity were available and if he chose to connect. However, the proof did not show capacity at either site. Although Petitioner does not intend to pollute the groundwater, the proof demonstrated that waste disposal into a septic tank from the maintenance and repair of farm equipment could result in the disposition of prohibited hazardous waste into the groundwater. Alternative methods of waste disposal are available which would properly dispose of the waste and, yet, protect the groundwater from contamination by hazardous waste. Such systems include certain aerobic treatment units and package plants. The monetary costs of these systems is greater than the septic tank proposal; however, the proof did not demonstrate that the cost was prohibitive or a hardship. Although the hardship, if any, caused by the denial of the variance was not caused by Petitioner, the proof failed to demonstrate lack of reasonable alternatives of waste disposal and the absence of adverse effect of the operation to the groundwater. Additionally, the proof failed to establish the ameliorating conditions of soil, water table or setback conditions although a survey of the property dated September 3, 1985, indicates that the subject parcel was not platted. Accordingly, the denial of the variance was proper.

Recommendation Based on the foregoing findings of fact and conclusions of law, it is RECOMMENDED that a final order be entered denying the variance. DONE AND ENTERED in Tallahassee, Leon County, Florida, this 6th day of July 1989. JANE C. HAYMAN Hearing Officer Division of Administrative Hearings The DeSoto Building 1230 Apalachee Parkway Tallahassee, Florida 32399-1550 (904) 488-9675 Filed with the Clerk of the Division of Administrative Hearings this 6th day of July 1989. COPIES FURNISHED: Lee B. Sayler, Esquire 50 South U.S. Highway One Suite 303 Jupiter, Florida 33477 Peggy G. Miller, Esquire Department of Health and Rehabilitative Services 111 Georgia Avenue Third Floor West Palm Beach, Florida 33401 Sam Power, Clerk Department of Health and Rehabilitative Services 1323 Winewood Boulevard Tallahassee, Florida 32399-0700 Gregory L. Coler, Secretary Department of Health and Rehabilitative Services 1323 Winewood Boulevard Tallahassee, Florida 32399-0700 John Miller General Counsel Department of Health and Rehabilitative Services 1323 Winewood Boulevard Tallahassee, Florida 32399-0700

# 4
THE CITY OF TALLAHASSEE vs. FALLSCHASE SPECIAL TAXING DISTRICT AND DEPARTMENT OF ENVIRONMENTAL REGULATION, 79-002303 (1979)
Division of Administrative Hearings, Florida Number: 79-002303 Latest Update: Apr. 02, 1980

Findings Of Fact Fallschase is a special taxing district which was created by the Board of County Commissioners of Leon County, Florida, in Leon County Ordinance No. 75-6. The district contains approximately 620 acres and is located in the area of the intersection of U.S. Highway 90 and Buck Lake Road in Leon County, Florida. The Intervenors are corporations which are seeking to develop the Fallschase area into a residential community. Through its permit application, Fallschase is seeking authority to construct a 167,000 gallon per day sewage treatment plant which would serve the proposed development. The plant would be of the extended aeration type with tertiary filters. Effluent from the plant would be discharged into a Percolation pond system. The City of Tallahassee operates a sanitary sewer system which serves areas within the city limits, as well as many unincorporated areas of Leon County. Service is provided to the unincorporated areas of the county in accordance with a contract between the City and Leon County which was executed in 1973. No election has been conducted within Leon County to authorize the contract. The County has terminated the contract, but the termination will not be effective until November 12, 1980. The City's sanitary sewer system is a regional system in that it serves a broad area not limited by the political boundaries of the City. The City's system has operated under temporary permits issued by the Department for a number of years because it does not meet the Department's requirements for tertiary sewage treatment. The City's regional sewage treatment system is capable of providing service to Fallschase. A 10-inch sewage pipe known as the "Belle Meade" Line runs adjacent to Fallschase. If a pumping station were constructed, sewage from Fallschase could be pumped into the Belle Meade Line and eventually into the City's primary sewage lines for treatment at one of the City's treatment facilities. In accordance with its statutory responsibilities, the Department has adopted Rule 17-4.26, Florida Administrative Code, which relates to permit requirements for sewage works. As filed with the office of the Secretary of State, the rule provided as follows: No person shall operate, maintain, construct, alter, modify, or expand any sewage collection system, sewage disposal system or sewage treatment facilities without a current and valid permit from the Department, pursuant to the Provision of Chapter 17-6, Florida Administrative Code. The Department shall deny an appli- cation for a permit and refuse to issue a permit unless the sewage collection, treatment and disposal system will pro- vide adequate and effective treatment in accordance with the rules and regu- lations of the Department and unless the system will operate as part of a regional system if one exists or be capable of tying into a regional system should one be established. Applications for a permit under this section shall be in accordance with Part I, Chapter 17-4, Florida Administrative Code. (e.s.) As filed with the Secretary of State, the rule included a clear policy choice in favor of regionalization of sewage treatment systems. In accordance with its responsibilities, the office of the Secretary of State published the rule in the Florida Administrative Code. When the rule was published in the Code, the portion of the rule which is underlined in the above quote was omitted. The rule as published in the Code thus did not include a clear statement requiring regionalization, and does not make sense. This erroneous version of the rule has been published in the Florida Administrative Code for more than five years, and the error has been compounded in that the Department has utilized the Florida Administrative Code version of the rule in its official handouts. A citizen requesting a current copy of Rule 17-4.26 from the Department, or from the Secretary of State's office, would receive the erroneous rule. The error has been further compounded because the Department subsequently adopted a policy of evaluating applications for sewage treatment proposals without regard to whether hookups to a regional system were possible. This policy has been applied by the Department for at least three years in accordance with verbal and written instructions of the Department's then Secretary, Jay Landers. Additional language was later added to Rule 17-4.26 as follows: Except for regional treatment plants, as designated by approved metropolitan or basin plans, all permits for treat- ment plants shall be valid only until connection, according to an approved plan, can be made to regional facilities. Such connection shall be made within ninety (90) days of the scheduled date for connection as provided in the approved plan. This provision has no applicability to the City's treatment system because the City's system has never been approved as the metropolitan or basin clan by the Department. The City has contended that the sewage treatment plant proposed by Fallschase would result in violations of the Department's standards for nitrates in the groundwater in the area of the plant. Nitrates would be a constituent of the effluent which would be discharged from the proposed sewage treatment plant into percolation ponds. The engineer who has designed the proposed plant estimated that total nitrogen discharged into the percolation ponds would be approximately 20 milligrams per liter, or parts per million (p.p.m.). In extended aeration plants such as that proposed by Fallschase, a substantial portion of the nitrogen would be in the form of nitrates. The 20 p.p.m. estimate is high. The experience generally in north Florida has been that nitrogen concentrations would not exceed 10 p.p.m. in the effluent discharged into percolation ponds. Once the effluent is discharged into the ponds, a certain amount of nitrogen is removed during the settling process. As the effluent percolates through the subsoils into the groundwater, further nitrogen is removed. Estimates of nitrogen removal through these processes range from a low of 25 percent to a high of 75 percent. The groundwater below the proposed plant is classified as Class 1-B groundwater under the Department's rules. It is very unlikely that effluent reaching the groundwater would contain as much as 10 p.p.m. nitrates. Even if it did, mixing with the groundwater would cause an almost immediate dilution of nitrogen concentrations so that concentrations in the groundwater as high as 10 p.p.m. would be unlikely in the extreme. Many sewage treatment plants operate within the Department's northwestern region, which extends from Pensacola to Tallahassee. The Department monitors these plants. A violation of the Department's nitrate standards has never been observed in the region. Indeed, in the entire State of Florida, nitrate violations have been detected only in certain areas of Dade County. Testimony was presented by the City to the effect that chemical processes in percolation ponds can cause very drastic nitrate concentrations when the funds are intermittently flooded and drained. Such concentrations have been observed at one of the City's treatment plants. The City`s plant, however, is of a different sort than that proposed by Fallschase. The City's plant produces concentrations of nitrogen in ammonia compounds and utilizes intermittent drying and flooding of the percolation ponds as a part of its operation. Ammonia compounds will not be a major constituent of effluent placed in the Fallschase percolation ponds; and, furthermore, the ponds will not be intermittently flooded and drained in the manner that would cause such concentrations to develop. In its Notice of Intent to Issue the proposed permit, the Department indicated that sludge produced through the proposed treatment facility should be disposed of by hauling to a plant operated by the City. The City has indicated that it will not make its plant available for such disposal, and cotends that accordingly Fallschase has given no reasonable assurances that the sludge will be disposed of properly. The contention is without merit. Many alternatives exist for disposal of sludge. Fallschase has adequate area available to it for construction of sludge drying pits. Sludge can be hauled to many potential locations. Specific issues respecting sludge disposal can be addressed in the operating permit which would not be issued by the Department until it is established that the proposed plant can operate within the Department's rules and regulations. The soils which lie below the proposed percolation ponds are not of a highly permeable sort. To aid in the percolation of effluent through the ground into the groundwater, Fallschase proposes to construct two-foot diameter holes in the bottom of the percolation ponds. The holes would extend from 18 to 25 feet below the bottom of the percolation ponds. The holes would be filled with sand, and alternatingly coarse layers of gravel. The City has contended that these holes would constitute wells, and that they therefore would need to be permitted by the Department. This contention is without merit. These structures could fit loosely within the definition of a well, but their function is merely to aid in the percolation of effluent through the subsoils. They are not designed to inject effluent directly into the groundwater. These structures would constitute wells to the same extent that any drain field would constitute a well.

Florida Laws (2) 120.53120.57
# 5
FRANK AND DENISE REPPA vs. DEPARTMENT OF HEALTH AND REHABILITATIVE SERVICES, 88-001790 (1988)
Division of Administrative Hearings, Florida Number: 88-001790 Latest Update: Aug. 23, 1988

Findings Of Fact The Respondents, Frank L. Reppa and Denise J. Reppa, own and reside in their dwelling located at 3863 Plumosa Drive, St. James, Florida. The property is a narrow canal front lot. All lots in the area are small and narrow and the dwellings thereon, mostly mobile homes, are placed closely together. On January 11, 1988, as the result of a nuisance complaint by the Reppa's next door neighbor, Stephen E. Havig, an Environmental Specialist with the Lee County Health Department, a part of the State of Florida DHRS, inspected the property in question and observed that effluent from the Respondents' drain field, a malodorous liquid, had run from Respondent's property down onto the driveway of their neighbors. On January 13, 1988, he returned to the property and spoke with Mrs. Reppa who admitted to living on the property. He again observed that the drain field in the Reppas' septic system was heavily saturated and had failed. Effluent was coming to the surface due to the high water table resulting from heavy recent rains and the failure of the system, and there was still a sewage odor to the effluent. The effluent showed in stains on the neighbor's drive. Mr. Havig told Mrs. Reppa that the problem had to be corrected as it was a violation of the law to allow it to remain. In response, Mrs. Reppa indicated they had no money to effect the repairs and because of that, Mr. Havig, who could have cited them immediately, indicated he would return to his office to see if they could be given some additional time to have the work done. After checking with his supervisor, Mr. Havig, on the same day issued an "Official Notification of Insanitary Nuisance" and a "Notice of Intended Action", both of which were sent by Certified Mail and receipted for by Mrs. Reppa on January 19, 1988. The Notice gave the Reppas until January 28, 1988 to correct the problem. On January 14, 1988, Mr. Havig again talked with Mrs. Reppa, telling her what he was sending and advising her how she could get the problem fixed. When he again went out to the property on January 28, 1988, he noted that the property had dried out due to a lack of rain. However, he could see no evidence that any repairs had been effected. He returned to the property on February 1, 1988 after a rain and observed that the problems had reoccurred. Mr. Havig again spoke with Mrs. Reppa on February 8, 1988, at which time she advised him the problem was to be repaired, but they were without funds to pay for it. At that time, Mr. Havig gave the Reppas three weeks to have the work completed with a contractor to be retained within one week. When he spoke with Mrs. Reppa on February 16, 1988, she stated she was still having trouble getting a contractor. She had contacted one contractor who looked at the system on February 15, 1988 and who proposed to remove the washing machine from the drain system. When Mr. Havig talked with Mrs. Reppa on February 19, 1988, she indicated she would have to discuss the matter with her husband. Mr. Havig stated at that time that the Department would have to proceed with enforcement action if work was not started on the correction by February 22, 1988. No corrective action was taken by the Reppas and the Administrative Complaint was filed as a result. DHRS considers it important to properly dispose of effluent because, since it contains human waste, it carries bacteria, viruses and a danger of parasites. Agency policy requires that the septic system be continually monitored and that the tank be pumped and the drain field be repaired when necessary. The Department has no funds available to assist those who cannot afford to make repairs. In order to be properly processed, effluent drainage from septic tanks needs a minimum of two feet of soil between the discharge outlet of the tank and the water table. The soil acts as a filter to remove harmful organisms and contaminants from the effluent before it reaches the water table. A high water table, due to heavy rains or other causes, prevents this filtration and causes the effluent to come to the surface. The situation is correctable. Two methods of correction are: 1) elevate the system above the water table, or 2) remove the saturated soil and replace it with a good grade of sand. In October, 1985, another complaint against the Reppas, relating to the same situation, was filed with DHRS. At that time, the Reppas paid $650.00 to have the system repaired by an individual who replaced the drain field, drawing it away from adjoining property and toward the road. Though the contractor assured them this would fix the problem, wash water would continue to come to the surface. As a result, Mrs. Reppa has refrained from washing clothes at her home and takes them to the laundry in town. Because of the actions they have taken, such as having the drain field expanded and moved, the pumping out of the septic tank in January, 1988, and the cessation of washing clothes at home, Mr. and Mrs. Reppa are convinced the system is not overflowing and that the water on the neighbor's property is the accumulation of surface water drainage when it rains. The Reppa property is higher than the neighbor's property and Mrs. Reppa believes that rain water drains down there. The new part of the drain field works and the water in question, she feels, cannot be effluent. The evidence of record, however, indicates to the contrary and that it is waste effluent. Inquiry by the Reppas indicates that it would take $750.00 more to fix the system and the Reppas do not have that money. They are still paying back the money they borrowed from Mrs. Reppa's parents to make the first repairs. Mr. Reppa is a commercial fisherman whose income has been substantially reduced due to the restrictions placed on the taking of redfish. Many neighbors in the area, according to the Reppas, discharge sewage directly into the abutting canal and allow wash water to run out onto the ground. The Reppas cannot comprehend why these individuals, mostly three month winter visitors, are not cited while they, full time residents, are.

Recommendation Based on the foregoing Findings of Fact and Conclusions of Law, it is, therefore: Recommended that an administrative fine of $50.00 per day be assessed against the Reppas for the violation established, said fine to be effective upon entry of a Final Order herein, with provision that the fine be remitted upon satisfactory proof that the violation has been corrected. Recommended in Tallahassee, Florida this 24th day of August, 1988. ARNOLD H. POLLOCK Hearing Officer Division of Administrative Hearings The Oakland Building 2009 Apalachee Parkway Tallahassee, Florida 32301 (904)488-9675 Filed with the Clerk of the Division of Administrative Hearings this 24th day of August, 1988. COPIES FURNISHED: Eugenie G. Rehak, Esquire Staff Attorney Department of Health and Rehabilitative Services Post Office Box 06085 Ft. Myers, Florida 33906 Frank Lee Reppa, pro se Denise J. Reppa, pro se 3863 Plumosa Drive St. James, Florida 33986 R. S. Power, Agency Clerk Department of Health and Rehabilitative Services 1323 Winewood Blvd. Tallahassee, Florida 32399-0700 Gregory L. Coler, Secretary Department of Health and Rehabilitative Services 1323 Winewood Blvd. Tallahassee, Florida 32399-0700

# 7
HILLSBOROUGH COUNTY DEVELOPMENTAL CENTER vs DEPARTMENT OF HEALTH AND REHABILITATIVE SERVICES, 89-003776 (1989)
Division of Administrative Hearings, Florida Filed:Tampa, Florida Jul. 14, 1989 Number: 89-003776 Latest Update: Oct. 24, 1989

Findings Of Fact The County is a political subdivision of the State of Florida, and the Hillsborough County Sheriff's Office is a department of the County government. On or about January 18, 1989, a site evaluation for the County's application, on behalf of the Hillsborough County Sheriff's Department, for an onsite sewage disposal system (septic tank and drainfield) at Vandenberg Airport was conducted. A soil profile was prepared showing brown sand from the ground surface down 14 inches, a gray sand down another 2 inches, and a gray clay from 16 inches to 7 feet below the surface. The United States Department of Agriculture Soils Survey Book classifies the soils found at Vandenberg Airport as Manatee fine sandy loam, which is now called Chobee 10, and characterizes its permeability as "severe" with a seasonal high water table of from 0 inches at ground surface to 10 inches below the ground surface. By letter dated April 13, 1989, the Department formally denied the County's application due to the poor texture of the Chobee 10 soil and high water table found in the site evaluation, as well as the zoning of the property. This denial letter recognized the applicant's right to apply for a variance. Since the County anticipated denial of its application due to verbal indications from Departmental representatives, the County filed an application for variance with the Department on or about March 29, 1989. A Variance Review Board met and considered the County's variance application, and then recommended approval. However, the variance application was denied by the Department on June 1, 1989, due to the nature of the activities to be conducted on the site, as well as the severe soil conditions on site. The denial of the County's variance request effectively denied its application for this permit. The County has timely sought this review of the Department's denial of its application for a permit for a septic tank and drainfield system at Vandenberg Airport for use by the Sheriff's Department. The parties stipulated that the County's application included the redesign plans and report of its consulting engineers. They further stipulated that the location for which this permit is sought is imperative to the duties of the Sheriff's Department, and there is no alternative to this location without greatly increasing the response time of the Sheriff's Department to emergencies and other calls for service. The Hillsborough County Sheriff's Department has been operating its aviation unit out of a hangar at Vandenberg Airport for several years, and in March, 1989, the County entered into a ten year lease with the Hillsborough County Aviation Authority for approximately 103,126 square feet of land (2.37 acres) located at the Vandenberg Airport for a new hangar for storage and maintenance of aircraft used in conjunction with the services provided by the Sheriff's aviation unit. The site was formerly used for three residences which were served by septic tanks. This lease specifically provides that the County is responsible for obtaining all necessary permits and for securing necessary utility services for the use of this Sheriff's hangar. Thus, the Aviation Authority is not responsible for providing sewage treatment facilities for this site. The Hillsborough County Aviation Authority is not a unit within Hillsborough County government, but is an independent entity established by Special Act. The County has no control or authority over the Aviation Authority's creation of development plans, but the County may approve or disapprove these plans after they have been created by the Aviation Authority and submitted to the County. The Authority's development plans for expansion of Vandenberg Airport provide for runway expansion, taxiways, aprons and parking for aircraft and hangar expansion. As part of this expansion, the Aviation Authority has removed 51 individual septic tanks from homes located on lands which have been acquired, and which now comprise part of Vandenberg Airport. There is no record of any problems with the three residential septic tanks formerly located on this site for 25 to 30 years. The Aviation Authority's plans do not include construction of a sewage treatment plant or providing sewage treatment services in any manner other than with septic tanks, the permits for which must be obtained by its lessees. No centralized wastewater service is available to the proposed Sheriff's hangar at the Vandenberg Airport, and the closest sewer main will be more than 10,000 feet away upon its completion in 1990. The County's five year capital improvement plan does not include extension of this sewer line to the Airport. The location for the Sheriff's hangar is currently zoned SPI-AP-V, which is a special airport district zoning classification created in September, 1989, for Vandenberg Airport. In this zoning district, manufacturing, processing and assembly activities are prohibited. Retail activities are also prohibited, as well as hotels, motels, repair services, physician and dental offices, bus and train terminals, lumberyards, warehouses, publishing and printing, and rental and leasing activities. This district is to be used for public use facilities, wastewater treatment plants and lift stations, aircraft landing fields, airport and airport related activities. "Airport" activities are defined to include fuel storage and transmission facilities, hangars, aircraft service, repair and maintenance facilities. "Airport related" activities are defined as: Uses which are dependent upon proximity to the airport for effective performance, or which provide services to the airport..., including but not limited to airport maintenance facilities and associated administrative offices; sales of new and used aircraft and aircraft parts; sales of aircraft fuels, lubricants, and other aircraft supplies; ... and other airport-related uses compatible with the operation of airports for public and private use. Based upon five soil borings taken at the boundaries of, as well as within, the proposed hangar site, Darrell Hanecki, a geotechnical engineer who was accepted as an expert in engineering, found that the groundwater table was 3 to 4 feet below the existing ground surface in October and November, 1988. The seasonal high groundwater table was estimated to be approximately 12 inches above the existing ground water table at that time, but significant fluctuations in the groundwater level were anticipated due to seasonal variations in rainfall, runoff, and other site specific factors. The borings upon which Hanecki's findings are based were performed in general compliance with accepted procedures for standard field penetration tests. Hanecki concluded that the soil conditions are suitable for the proposed hangar if constructed on a shallow footing foundation with special site preparations. William Fernandez, who was accepted as an expert in civil engineering, developed a redesign of the County's septic tank and drainfield in support of its variance request in order to address concerns expressed by the Department's representatives concerning soil conditions on site. It is proposed that the septic tank and drainfield site will be excavated to a depth of 6 feet, and all clays will be removed. The site will then be backfilled with clean materials in order to allow the drainfield to percolate through these clean materials from three mounded drains which will be located in a two foot high mound constructed above the original grade. A pump will be used to lift the effluent from the tank to the drainfield. The septic tank will have a 750 gallon capacity. It is projected that 8 people will use this septic tank each day, and that each person will cause 25 gallons of sewage per day to be deposited in the system, or a total of 160 gallons of sewage per day. Only domestic wastes from the hangar restrooms will go into the system. Oils, greases and other substances used in aircraft maintenance and repair will be separated and carried to a retention pond through a system of trenches. After hearing the testimony of the County's expert witnesses about the surface water management system to be constructed on site, the Department's environmental specialist, Gary Schneider, testified that he was no longer as concerned about the possibility of oils, greases and other hazardous materials getting into the septic tank system. The County has also applied to the Southwest Florida Water Management District for a surface water management permit, and must receive that permit for this proposed hangar at Vandenberg Airport. The Department seeks to rebut the expert testimony offered by the county primarily with the testimony of Robert Blanco, supervisor of the county health department's septic tank permit program, who was neither tendered nor accepted as an expert, as well as a letter from Richard Ford, resource soil scientist with the Soil Conservation Service, dated September 18, 1989, who took one soil boring and concluded that the soil identified was poorly drained to very poorly drained Chobee loamy sand. Ford was not present to testify. Blanco agreed with Ford's conclusion, expressed in his letter, that the seasonal high water table on this site will come to the surface, or within 10 inches of the surface, for 2 to 6 months each year, causing ponding to occur. Based upon the demeanor and qualifications of the witnesses who testified at hearing, it is specifically found that the testimony offered in support of the County's application, and in particular the expert testimony of Hanecki and Fernandez, is more credible and is given greater weight than the testimony offered on behalf of the Department, particularly the testimony of Blanco. Blanco was not qualified or tendered as an expert in any field, and therefore, he was only competent to offer fact testimony. He speculated, without any supporting evidence in the record, that the septic tanks formerly on this site were not built to Code specifications and probably did not work, although there is no evidence of any complaints about these septic tanks during the 25 to 30 years they were in operation. Blanco also insisted that standardized texts describing soil types over large geographic areas are more reliable than actual soil borings on site, although he could not render an expert opinion in this regard. The letter from Ford offered by the Department was not supported by other competent, substantial, credible evidence, and in any event was based upon only one soil boring as opposed to five borings conducted by Hanecki in accordance with generally accepted practices. Therefore, it is found that the groundwater table on this site is 3 to 4 feet below the existing ground surface, and the seasonal high groundwater table is approximately 12 inches above the existing groundwater table, although it does fluctuate. It was undisputed at hearing that the soils on site are Chobee 10, which is poorly to very poorly drained soil, but the County's redesign of the proposed septic tank and drainfield reasonably and adequately accounts for, and accommodates, this condition by excavating to a depth of 6 feet and backfilling with clean materials, and by placing three drains in a mounded drainfield built two feet above the existing ground level. This redesign complies with the requirements and provisions of Chapter 10D-6, Florida Administrative Code.

Recommendation Based upon the foregoing, it is recommended that the Department enter a Final Order granting the application of Hillsborough County for a permit for an onsite sewage disposal system (septic tank and drainfield) for the Sheriff's Department hangar at Vandenberg Airport. DONE AND ENTERED this 24th day of October, 1989 in Tallahassee, Florida. DONALD D. CONN Hearing Officer Division of Administrative Hearings The DeSoto Building 1230 Apalachee Parkway Tallahassee, Florida 32399-1550 (904) 488-9675 Filed with the Clerk of the Division of Administrative Hearings this 24th day of October, 1989. APPENDIX TO RECOMMENDED ORDER, CASE NO. 89-3776 Rulings on the County's Proposed Findings of Fact: 1. Adopted in Finding 1. 2-7. Adopted in Findings 6, 7. Adopted in Finding 8. Adopted in Finding 7. Adopted in Finding 10. Adopted in Findings 9, 12. 12-13. Adopted in Findings 2, 3. Adopted in Findings 10, 12. Adopted in Findings 3, 5, 10. Adopted in Findings 3, 4. Rulings on the Department's Proposed Findings of Fact: Adopted in Finding 6. Adopted in Finding 8. 3-4. Adopted in Finding 2. Adopted in Finding 11; Rejected in Finding 12. Rejected in Finding 12 as irrelevant and immaterial since the classification of the soils on site was not disputed at hearing. Adopted in Finding 5. Adopted and Rejected in part in Finding 12. COPIES FURNISHED: Michael J. Morrison, Esquire Assistant County Attorney 725 East Kennedy Boulevard Tampa, Florida 33602 Raymond R. Deckert, Esquire W. T. Edwards Facility 4000 West Buffalo Avenue Room 500 Tampa, Florida 33614 John Miller, General Counsel 1323 Winewood Boulevard Tallahassee, Florida 32399-0700 Sam Power, Agency Clerk 1323 Winewood Boulevard Tallahassee, Florida 32399-0700 Gregory Coler, Secretary 1323 Winewood Boulevard Tallahassee, Florida 32399-0700

Florida Laws (1) 120.57
# 9
PINELLAS COUNTY CONSTRUCTION LICENSING BOARD vs LARRY L. BOSWORTH, 94-007207 (1994)
Division of Administrative Hearings, Florida Filed:Largo, Florida Dec. 27, 1994 Number: 94-007207 Latest Update: Sep. 05, 1995

Findings Of Fact At all times pertinent to the allegations herein, the Petitioner, Pinellas County Construction Licensing Board, (Board), was the Pinellas County agency responsible for the certification and regulation of construction specialties. Respondent was certified by the Board as an irrigation systems specialty contractor under license C-5997 in force at the time. Respondent was the qualifying contractor for Sun City Lawn Irrigation. On or about May 17, 1994, Respondent contracted with William J. Schneider, who resided at 5661 25th Avenue North in St. Petersburg, to install a lawn irrigation system in Mr. Schneider's front lawn. The automatic system was to incorporate 2 zones and was, according to the contract and the testimony of Mr. Schneider, to be connected to Schneider's then existing 1/2 horsepower electric pump which drew water from several wells on his property. Mr. Schneider claims there are four wells. No evidence was introduced to contradict that. On the day the system was installed, Mr. Schneider was not at home. Respondent's employees performed a test of the water capacity on Mr. Schneider's property. At first, the wells produced 10 gpm, which was adequate for the system, but after a few minutes of drawdown, they found that the wells were producing only 4 gpm, along with some air. At that time Mr. Freestone, Respondent's sales manager, spoke with Mrs. Schneider about the situation, advising her there were two options open. One was to install a larger pump and the second was to connect the system to the city water supply. Mrs. Schneider returned to the house, presumably to call Mr. Schneider to get his decision on the matter. He claims she did not reach him. Respondent claims that she thereafter returned with directions to install a water line for connection to the city system. This is completely contrary to what Mr. Schneider had wanted and to what is included in the contract. Mr. Schneider claims he did not want to connect to city water because of the added expense of doing so, and he claims he made this very clear to Respondent's employees at the beginning and at all times thereafter. In any case, the system was installed and was, somehow, connected to the city water system near the place where the water line enters the house. In addition, no backflow preventer was installed to insure against contamination getting into the water system as is required by the building code. Most, if not all, the work on this project was completed by Respondent's son and employee, Scott, who was not present at the hearing. Respondent attempted to introduce an unsworn written statement by Scott Bosworth, but it was not accepted. Scott advised Mr. Schneider, when he returned from work that day, that they had been unable to use his pump and wells. Nonetheless, Mr. Schneider paid Respondent in full for the work for which he had contracted, except for a supplemental charge in the amount of $190.95 for the tie in to the city water and the valves and other items connected therewith. Mr. Schneider claims that he made several calls to Respondent's office in an effort to correct the situation but was unable to reach anyone who could give him satisfaction. However, the evidence indicates that on at least one occasion, Mr. Schneider got through and was called back by Mr. Freestone with whom he discussed the situation and the additional charges. He was subsequently advised by counsel that he did not have to pay the additional sum and did not do so. Some time thereafter, Mr. Schneider was advised by the city that he would be fined because of the illegal installation. He then contacted another irrigation company, run by Mr. Williams, who examined the system and determined that the irrigation system installed by Respondent had been connected to the city water system and that no backflow preventer had been installed. A check with the city's building department revealed that no permit had been procured for this installation. Respondent's license to install irrigation systems does not include authority to connect that system with the public water system. That procedure must be done by a licensed plumber. Respondent and Mr. Freestone, the only individuals in the company who had the authority to arrange with a plumber to make the actual hook up to the city system, both deny that any arrangement was made by them to have the system connected to the city water system. Mr. Schneider arrived home on the day in question to find only Respondent's son, Scott, at work on the project. Scott indicated it would be necessary to move two bushes near the house to facilitate connection of the system with the water supply. Mr. Schneider contracted with Scott to move the bushes and remove them from the premises. Scott moved them but failed to remove them. In light of the fact that Scott was working on the system at the time Mr. Schneider arrived home, and the system was found to be connected to the city system thereafter without anyone else touching it, it must be concluded that the connection was made him. Respondent admits he did not come to the property in question while the system was being installed.

Recommendation Based on the foregoing Findings of Fact and Conclusions of Law, it is, therefore: RECOMMENDED that a Final Order be issued by the Board suspending the license of the Respondent for a period of six months with provision for withholding execution of the suspension for a period of one year conditioned upon such criteria as may be deemed appropriate by the Board. RECOMMENDED this 31st day of March, 1995, in Tallahassee, Florida. ARNOLD H. POLLOCK Hearing Officer Division of Administrative Hearings The DeSoto Building 1230 Apalachee Parkway Tallahassee, Florida 32399-1550 (904) 488-9675 Filed with the Clerk of the Division of Administrative Hearings this 31st day of March, 1995. COPIES FURNISHED: William J. Owens Executive Director Pinellas County Construction Licensing Board 11701 Belcher Road Largo, Florida 34643-5116 Larry J. Bosworth 8901 14th Street North St. Petersburg, Florida 33716

Florida Laws (1) 120.57
# 10

Can't find what you're looking for?

Post a free question on our public forum.
Ask a Question
Search for lawyers by practice areas.
Find a Lawyer