The Issue The issues, as framed by the Administrative Complaint, are twofold: Whether Respondent committed gross negligence, incompetence, or misconduct which caused monetary harm to a customer, in violation of Florida Administrative Code Rule 64E-6.022(1)(l)2; and Whether Respondent practiced fraud or deceit by making a misleading or untrue representation to a home purchaser, or the home purchaser's agents, incident to a loan application, in violation of Florida Administrative Code Rule 64E-6.022(1)(k).
Findings Of Fact Petitioner, Department of Health, is an agency of the State of Florida as defined in Section 120.52, Florida Statutes. Petitioner's actions in this matter are governed in part by Chapters 381 and 489, Florida Statutes, as well as Florida Administrative Code Chapter 64E-6. Respondent, at all times material to this matter, was licensed by Petitioner under Part III of Chapter 489, Florida Statutes, entitled, "Septic Tank Contracting." Respondent is subject to the regulatory jurisdiction of Petitioner, having been issued Registration Number SR0931141 to engage in septic tank contracting, and Certificate of Authorization Number SA0890161 to do business as Superior Septic and Sewer, Inc. Petitioner seeks to impose revocation of Respondent's License and Certificate of Authorization for violations of Florida Administrative Code Rule 64E-6.022(1)(l)2. and (1)(k), with aggravation pursuant to Rule 64E-6.022(2). Air Force Captain Timothy Billings made an offer that was accepted to purchase a home located at 1938 Quail Run, Lynn Haven, Florida, prior to September 12, 2008. Captain Billings worked with a realtor, Bonnie Milstead, and arranged the various steps required to secure a Veterans Administration loan with the seller's realtors, Ben and John Harrell. A septic tank inspection and certification was one of the loan requirements. On behalf of Captain Billings, Ms. Milstead arranged to have Respondent's company inspect and certify the septic tank at 1938 Quail Run at a price of $250. The price included the pumping of the tank for $225 and a $25 charge for the certification. Captain Billing paid the $250 charge at the closing on the purchase of the home. John E. McDaniel is the licensed septic tank contractor for Superior Septic and Sewer, Inc., and is the qualifying contractor for a Certificate of Authorization to do business as Superior Septic and Sewer, Inc. On September 15, 2008, one of Respondent's employees, Phillip Fetner, went to 1938 Quail Run where he was met by Ben and John Harrell, realtors for seller of the home. Mr. Fetner was there to inspect only the septic tank, not being equipped or trained to inspect the entire system and drainfield. Mr. Fetner opened the tank after cutting through roots that had grown into it. He noted a large amount of roots in the tank that was also seen by the realtor, Ben Harrell. In spite of the roots, Realtor John Harrell instructed Mr. Fetner to "go ahead and pump the tank," which he did. He told John Harrell there were still a lot of roots in the tank. Mr. McDaniel discussed with John Harrell an additional charge of $400 to remove the roots from the tank. Mr. Harrell did not order the additional work. Mr. McDaniel believed that enough roots had been removed from the tank by Mr. Fetner for a certification to be issued, but Mr. Fetner did not confirm this. Debbie Bass, a clerical staff member of Respondent, completed the certification form prior to the inspection being complete. This was her custom so that she could stay ahead of the work load. The form was left in the inbox to be signed by Mr. McDaniel. Ms. Bass did not falsify any records nor had she ever been asked to do so in her four-and-a-half years with Respondent. The certification form was signed by Mr. McDaniel without the additional root work having been done by his company. The mortgage lender relied upon the certification to make the loan to Captain Billings. Mr. McDaniel did not directly inform Captain Billings or his realtor, Ms. Milstead, that the septic tank was full of roots. He believed that the root situation had been disclosed since the seller's realtors, the Harrells, had been on-site at the time of the inspection. Captain Billings testified that had he been fully aware of the root situation, he would have probably walked away from the deal because he did not want to have to deal with problems in the future. Mr. McDaniel allows his wife, Lisa McDaniel, to sign his name in his capacity as a licensed septic tank contractor. Lisa McDaniel actually signed the certification on the 1938 Quail Run property. Respondent's position is that the certification was sent out by mistake because the root removal work had not been performed on the tank. Mr. McDaniel does not dispute the fact that the certification form was prepared and signed. Captain Billings experienced problems with the septic tank system of his newly purchased home at 1938 Quail Run. In March 2009, he discovered the septic tank and system were full of roots and not functioning when Roto-Rooter, owned and operated by Glenn Salyer, removed the manhole access for a pump out and saw the massive roots. After learning from his realtor that Respondent had been hired to inspect the septic tank, Captain Billings contacted Mr. McDaniel, who refused to do anything about the situation. Even after the filing of the Administrative Complaint, Mr. McDaniel refused to remedy the situation. Glenn Salyer of Roto-Rooter, a licensed master septic tank contractor and master plumber, would not have certified the septic tank at 1938 Quail Run in its September 15, 2008, condition. Lyle Ake, another licensed septic tank contractor, would not have certified the septic tank at 1938 Quail Run in its September 15, 2008, condition. The septic tank should not have been certified in its September 15, 2008, condition. Roots intruding into the septic tank indicate it is not watertight. However, a system having roots can perform properly without incident for many years. When the entire system was inspected by Mr. Salyer, it was non-functional and needed replacement. Roto-Rooter replaced the septic tank system, consisting of a new septic tank and drainfield, at 1938 Quail Run on October 12, 2009. Captain Billings paid $4,500 for the replacement system. According to David Hammonds, an expert on the rules and functioning of septic tank systems, the system was being inspected and evaluated pursuant to Florida Administrative Code Rule 64E-6.001(5), the Procedure for Voluntary Inspection and Assessment of Existing Systems. The Rule provides specific items to be inspected unless the requesting party, in writing, states that specific items are not to be inspected. Mr. Hammonds testified that after his review of the exhibits and the site, he concluded that the septic tank system at 1938 Quail Run was "a failing system." Mr. Hammonds concluded that the pump-out procedure could have been completed once enough roots were removed to get the pump into the tank. Mr. Hammonds noted that the roots had been in the tank for a very long time, maybe years. Roots in the tank can lead to many problems. Roots affect capacity; they damage the tank itself, leading to cracks and leaks; and can lead to the leaking of sewage around the tank cover and seams. Mr. Hammonds noted that the high fluid level in the tank, almost up to the lid, is an indication of the entire system not working properly. The reporting requirements in the Voluntary Assessment Rule do not require the use of a particular inspection form. The Rule does specify what must be inspected and reported. Respondent accurately listed the features of the tank on the certification form: the tank was 1,050 gallons; the tank had neither a baffle nor a filter; and the tank was structurally sound. Mr. McDaniel believes this matter is all the result of an office error and that he should not be held responsible. Mr. McDaniel has a history of disciplinary matters with Petitioner. He has been cited for 18 violations in six cases as well as a non-disciplinary letter of concern. On September 13, 1996, he was fined $50 for inspecting a system without a permit. On September 13, 1996, he was fined $100 for two repairs to a system without a permit and for violating water table separation and setback from a potable well. DOAH Case No. 99-2474 resulted in a Final Order imposing an administrative fine of $3,300 for the removal of tank filters after final inspection by department personnel. Judge P. Michael Ruff found in that case that Respondent's actions "show a clear intent to mislead regulatory authorities." DOAH Case No. 04-1636 was settled by stipulation and resulted in a letter of warning with amelioration of a new drainfield installed by Respondent for an original drainfield that was improperly installed. On December 2, 2005, Respondent was issued a Letter of Warning for improper disposal of sewage. DOAH Case No. 07-1651 resulted in jurisdiction in the matter being relinquished to Petitioner based upon Respondent's non-appearance at the final hearing. The result was a fine of $500 for submitting a repair permit application with an incorrect site plan not showing a shed and a fence positioned over and in an existing drainfield. A Letter of Concern was issued July 23, 2007, to Respondent for improperly reporting a larger than actual capacity of a septic tank. A Letter of Concern is not a formal discipline under Florida Administrative Code Rule 64E-6.022, but demonstrates substandard performance by a licensee. Mr. McDaniel believes that other septic tank contractors have received lighter treatment for their offenses than he has. Bob Glenn, Petitioner's Environmental Manager for the Bureau of Onsite Management Program, gave some credence to Respondent's perception.
Recommendation Based upon the Findings of Fact and Conclusions of Law, it is RECOMMENDED that a final order be issued by the Department of Health suspending Respondent for six months; suspending Respondent's Septic Tank Contractor Registration Number SR0931141 and Certificate of Authorization Number SA0890161 to do business as Superior Septic and Sewer, Inc.; and imposing a fine in the amount of $1,000.00, on Respondent. DONE AND ENTERED this 25th day of February, 2010, in Tallahassee, Leon County, Florida. S ROBERT S. COHEN Administrative Law Judge Division of Administrative Hearings The DeSoto Building 1230 Apalachee Parkway Tallahassee, Florida 32399-3060 (850) 488-9675 Fax Filing (850) 921-6847 www.doah.state.fl.us Filed with the Clerk of the Division of Administrative Hearings this 25th day of February, 2010. COPIES FURNISHED: Rodney Marcum Johnson, Esquire Department of Health 1295 West Fairfield Drive Pensacola, Florida 32501 John E. McDaniel Superior Septic and Sewer, Inc. 7315 Highway 231 North Panama City, Florida 32404 Dr. Ana M. Viamonte Ros, Secretary State Surgeon General Department of Health 4052 Bald Cypress Way, Bin A00 Tallahassee, Florida 32399-1701 Josefina M. Tamayo, General Counsel Department of Health 4052 Bald Cypress Way, Bin A02 Tallahassee, Florida 32399-1701 R. S. Power, Agency Clerk Department of Health 4052 Bald Cypress Way, Bin A02 Tallahassee, Florida 32399-1701
The Issue Whether Respondent, Virgil Cardin, d/b/a Virgil Cardin Septic Tank Service (Respondent or Cardin), committed the violations alleged in the Administrative Complaint for Imposition of Administrative Fines and Revocation of Septic Tank Contractor License and Business Authorization, dated December 28, 2012, and, if so, what penalty should be imposed.
Findings Of Fact The Parties Petitioner is the state agency charged with the responsibility of administering the Standards for Onsite Sewage Treatment and Disposal Systems (SOSTDS). The installation, repair, and/or alteration of any septic tank system fall within the purview of Petitioner's authority. Public health concerns mandate that all septic tank systems be operated according to governing laws and rules. Respondent is a resident of the State of Florida and is registered by Petitioner to provide septic tank contracting services within the state. Respondent's registration number is SR0890865. Respondent owns and operates Virgil Cardin Septic Tank Service located in Lakeland, Florida, and the company is authorized to provide septic tank contracting services. The company's authorization number is SE093690. Septic tank contracting services are governed by SOSTDS. The Controversy It is undisputed that a permit must be obtained prior to performing repairs to a septic tank system. In Polk County (where all actions complained of occurred), a septic tank service company is required to apply for a permit before work is performed, obtain an inspection by appropriate authorities before beginning work, and complete all work in accordance with designated standards. A septic tank pump-out does not require a permit. Any work that would involve the exposure of the drain fields and/or the refitting of portions of the septic system would require a permit. The controversy in this case stems from Respondent's failure to obtain a permit before beginning repairs to a septic tank system located at 4931 Rolling Meadows Drive, Lakeland, Florida. It is undisputed that Respondent did not, in advance of starting work at the home, obtain a permit. The Arguments The Digans own a home located at 4931 Rolling Meadows Drive, Lakeland, Florida. For several years, the Digans have experienced problems with their septic tank system to the point that waste from the septic system has backed up into their home. Previously, Respondent addressed the Digans' septic tank system problems by pumping the waste from the tank, thereby eliminating pressure on the overwrought system. On or about August 24, 2012, Respondent went to the Digans' home and pumped out the septic tank. A permit for the work done that date was not required. Given the history of the problems with the Digans' system, it became apparent to the owners and Respondent that comprehensive repairs to the system were necessary. As there was no way to predict when another pump-out might be required, it was not surprising that approximately one week later Respondent returned to the Digans' property for additional work. On that date, September 1, 2012, Respondent could not pump out the Digans' tank, because his truck was already full. Instead, Respondent took a backhoe to the Digans' property and began to dig trenches for the drain field. Respondent's employee began to construct a septic drain line header pipe with drain field chamber end plates attached. Respondent exposed the Digans' septic system as if he were going to make repairs to the system. When confronted by two environmental supervisors who observed Respondent's actions, Respondent readily admitted he did not have a permit for the work. At first, Respondent stated that the homeowners could not afford permits. Later, Respondent maintained that the work he performed on September 1, 2012, did not require a permit. Petitioner maintains that Respondent went to the Digans' home on September 1, 2012, to make repairs to the septic tank system without prior inspection or a required permit. The Analysis Prior to September 1, 2012, Respondent knew or should have known that the Digans' septic tank system needed extensive repairs. Respondent had pumped out the tank several times and should have known that the system was not functioning as intended. Prior to September 1, 2012, Respondent knew or should have known that repairs to any septic tank system require an inspection and permit. On September 4, 2012, after being caught the prior Saturday on the Digans' property, Respondent applied for a permit for the repairs to the Digans' septic tank system. On September 5, 2012, a repair permit was issued for the Digans' property. On September 7, 2012, the repairs to the Digans' system were inspected and approved. There was no emergency on September 1, 2012, that necessitated repairs to the Digans' septic tank system on that date. Pumping out the Digans' tank on that date would have addressed any immediate concern. On-site inspections before septic tank systems are repaired are critical to public health because they assure that groundwater contamination is avoided, that the existing tank is sound and will function as intended, and that setbacks to other properties, wells, or systems are adequate. Respondent knew or should have known that performing any work before an inspection negates the safeguards to public health concerns. Respondent knew or should have known that the materials needed to adequately repair the Digans' septic tank system exceeded the chambers he took to the site on September 1, 2012. Digging up the Digans' system on September 1, 2012, created a sanitary nuisance. Respondent's History In the event a violation is found in this case, Respondent's disciplinary history would be relevant in considering what penalty, if any, should be imposed. To that end the following findings are made: Respondent has previously been found in violation of failing to call for a required inspection; and Respondent has previously been found in violation of practicing fraud or deceit, making misleading or untrue misrepresentations, or misconduct that causes no monetary harm to a customer.
Recommendation Based on the foregoing Findings of Fact and Conclusions of Law, it is RECOMMENDED that Respondent's authorizations to perform septic tank services be suspended for a period not less than 90 days. Additionally, it is RECOMMENDED that Respondent be required to pay an administrative fine in an amount not less than $2,000.00. DONE AND ENTERED this 6th day of May, 2013, in Tallahassee, Leon County, Florida. S J. D. PARRISH Administrative Law Judge Division of Administrative Hearings The DeSoto Building 1230 Apalachee Parkway Tallahassee, Florida 32399-3060 (850) 488-9675 Fax Filing (850) 921-6847 www.doah.state.fl.us Filed with the Clerk of the Division of Administrative Hearings this 6th day of May, 2013. COPIES FURNISHED: John H. Armstrong, M.D., F.A.C.S. State Surgeon General Department of Health Bin A00 4052 Bald Cypress Way Tallahassee, Florida 32399-1701 Jennifer A. Tschetter, General Counsel Department of Health Bin A02 4052 Bald Cypress Way Tallahassee, Florida 32399-1701 Althea Gaines, Agency Clerk Department of Health Bin A02 4052 Bald Cypress Way Tallahassee, Florida 32399-1703 Tony C. Dodds, Esquire Law Office of Tony C. Dodds 904 South Missouri Avenue Lakeland, Florida 33803-1034 Roland Reis, Esquire Polk County Health Department 1290 Golfview Avenue, Fourth Floor Bartow, Florida 33830-6740
The Issue The issue to be resolved in this proceeding concerns whether the Petitioner violated Florida Administrative Code Rules 64E-6.022(1)(b)2, 64E-6.022(1)(d), and 64E-6.022(1)(p) by making repairs to an on-site sewage disposal system without a permit, and by missing required inspections of the system, as outlined in the citation issued by the Respondent Agency dated August 29, 2005.
Findings Of Fact The State of Florida, Department of Health and Duval County Health Department (Department) is an Agency of the State of Florida, charged with enforcing the statutory and regulatory provisions regarding septic tank and drain field installations and repairs, in Florida, in accordance with Section 381.0065, Florida Statutes, and Florida Administrative Code Rule Chapter 64E-6. The Petitioner is the qualifying registered septic tank contractor for All Florida Septic Tank Service, Inc. (All Florida). He holds registration number SR00011389. He has 15 years of experience in the field of septic tank system construction and repair. All repairs of on-site sewage treatment and disposal systems (septic systems), are required to be performed under the supervision and control of a registered septic tank contractor. Mr. David Adeeb is president of United Properties of North Florida, Inc. He owned property (a residence) at 375 North Cahoon Road, in Duval County Florida. He was informed by his tenants at that residence that the septic tank and drain field were malfunctioning and needed to be repaired or replaced, sometime in April 2004. He therefore contacted All Florida, asking them to inspect the septic system at that residence and advise what repairs might be needed. He was advised by some representative of All Florida that the drain field needed to be replaced and was quoted a price of $2,000.00. All Florida requested that payment be made before the work was performed. Since Mr. Adeeb was out-of-town at the time he asked his tenant to temporarily pay All Florida for the cost of the repairs and/or installation, which they agreed to do. All Florida then issued a contract/proposal to United Properties on April 12, 2004. It was signed by a representative of All Florida, Michael Carver. Mr. Carver was an employee of All Florida. The contract/proposal indicated that a 360 square foot drain field would be installed at 375 Cahoon Road, for a price of $2,000.00, to be paid in cash. The contract/proposal was on All Florida letterhead and included a warranty. Mr. Adeeb was told by his tenant that the Petitioner, who is personally known to that tenant, was on the property while the work was being performed. No one applied for a permit to make any repairs to the septic system and the work was completed without a permit being obtained. Some five months later the system began leaking sewage from the new drain field. It had malfunctioned. Mr. Adeeb therefore again called All Florida to demand that they repair any malfunctions pursuant to the warranty. All Florida informed Mr. Adeeb that a new drain field with a mounded system and pump was needed. When Mr. Adeeb told a representative of All Florida that they had just replaced the drain field in April of that year, he was told that another $2,000.00 would be required to correct the drain field problem. Mr. Adeeb had just recently entered into a contract to sell the property at 375 Cahoon Road so, time being of the essence in closing the sale of the property, he felt he had no choice but to ask All Florida to go ahead with the repair work on the system which All Florida had been asked by him to repair five months previously in April of 2004. After the new system was installed Mr. Adeeb found that a permit had never been obtained for the first drain field work which he had requested from All Florida and that All Florida had done the work incorrectly. Mr. Adeeb objected to paying another $2,000.00 for the second repair job, performed in approximately September of 2004 and after much discussion with All Florida's representatives agreed to pay $1,000.00 dollars for the second stint of repair work. He made the payment and he received a warranty from All Florida for one year, good through September 22, 2005. The warranty was signed by Mr. Wayne Joyner, operations manager for All Florida. Mr. Joyner is also the qualifying registered septic tank contractor for AA Septic Tank Service, Inc., apparently a second corporation domiciled at the same facility and address as All Florida Septic Service, Inc. In May of 2005 Mr. Adeeb was again contacted by the now former tenant who had purchased the property from Mr. Adeeb. He was thus informed that the system had failed again and sewage was leaking onto the surface of the property from the drain field. Mr. Adeeb again contacted All Florida on May 23, 2005. A representative of All Florida informed him that he should fax a copy of the paid receipt and the warranty to them and that they would take care of the problem. On June 20, 2005, the home owner again contacted Mr. Adeeb and told him that no one from All Florida had repaired the drain field as yet. A faxed copy of the paid receipt and warranty was requested once again by All Florida. After numerous phone calls with representatives of All Florida, Mr. Adeeb was told that the problem was not due to All Florida's repair work and that Mr. Adeeb would need to get someone else to repair the system. The Petitioner, James L. Smith, the registered qualifying septic tank contractor for All Florida, testified that Michael Carver had performed the initial repair job in April of 2004 for Mr. Adeeb without the knowledge of the Petitioner or All Florida. He claims that Michael Carver never worked for All Florida. He introduced into evidence a letter purported to be from Michael Carver which was dated September 30, 2005, but signed on October 5, 2005. That letter states that Mr. Carver performed the first drain field repair job without the knowledge of All Florida and that he had created the receipt form which was apparently given to either the tenants at the residence in question, or to Mr. Adeeb, on All Florida letterhead without the knowledge of any officer, employee, or representative of All Florida. That letter, however, was not authenticated because Mr. Carver was not present at the hearing and could not be examined concerning it, or the details of Mr. Carver's involvement with the initial repair project. Moreover, the Petitioner was unable to explain how Mr. Carver would have known about the job at all if he had never worked for All Florida. This is because Mr. Adeeb established that in obtaining all of the repair work during 2004-2005 he had only contacted representatives of All Florida. He had never had contact with Mr. Carver. The Petitioner denied ever telling counsel for the Department in a telephone conversation that Michael Carver had worked for him during the week (i.e. All Florida) but that he let Mr. Carver do "side jobs" on his own on weekends. He claimed that Mr. Carver did the job in question in April of 2004 because the tenants knew him personally and arranged for him to do the work. The testimony of Mr. Adeeb and the Department's evidence in the form of its composite exhibit, is accepted as more credible than the self-serving testimony of the Petitioner, and it is found that All Florida and the Petitioner were responsible for the repair jobs at issue in this case because Mr. Adeeb contracted with All Florida for the work in question. Even if the initial job was performed by Mr. Carver, it is determined that he did so as employee or agent of All Florida and the Petitioner. Under the authority cited herein the Petitioner was responsible, as the qualifying, registered septic system contractor for All Florida, with performance and supervision of the work in question.
Recommendation Having considered the foregoing Findings of Fact, Conclusions of Law, the evidence of record, the candor and demeanor of the witnesses, and the pleadings and arguments of the parties, it is, therefore, RECOMMENDED that a final order be entered by the Respondent Department finding that the violations charged have been established and that a fine of $2,500.00 dollars be imposed for the violations. DONE AND ENTERED this 30th day of March, 2006, in Tallahassee, Leon County, Florida. S P. MICHAEL RUFF Administrative Law Judge Division of Administrative Hearings The DeSoto Building 1230 Apalachee Parkway Tallahassee, Florida 32399-3060 (850) 488-9675 SUNCOM 278-9675 Fax Filing (850) 921-6847 www.doah.state.fl.us Filed with Clerk of the Division of Administrative Hearings this 30th day of March, 2006. COPIES FURNISHED: James L. Smith 8300 West Beaver Street Jacksonville, Florida 32220 Catherine R. Berry, Esquire Department of Health 515 West Sixth Street Jacksonville, Florida 32206-4311 R. S. Power, Agency Clerk Department of Health 4052 Bald Cypress Way, Bin A02 Tallahassee, Florida 32399-1701 Timothy M. Cerio, General Counsel Department of Health 4052 Bald Cypress Way, Bin A02 Tallahassee, Florida 32399-1701
The Issue The issue in this case is whether the Department should grant and approve Petitioner’s application as a septic tank contractor.
Findings Of Fact The Department of Health is the agency responsible for the registration of septic tank contractors and the authorization of septic tank companies. The Department of Health enforces the statutes and rules pertaining to the registration and authorization of septic tank contractors and septic tank companies pursuant to Chapters 381 and 489, Part 3, Florida Statutes, and Rule 10D-6, Florida Administrative Code. The Petitioner, Gerald D. Thompson, applied to the Department of Health to be a registered septic tank contractor. The Department received his application on July 3, 1996. The Petitioner’s application indicates that he had been convicted of a crime related to septic tank contracting and had had an enforcement action taken against him. The attachment to the application reflected that both events had occurred to the Petitioner. The Petitioner had been adjudged guilty, in Flagler County Circuit Court, on January 18, 1997, of the attempted felony littering by disposing of domestic sewage on private property in an area not permitted for such use. Petitioner’s previous septic tank contracting registration had been revoked for two (2) years in a settlement agreement between the Petitioner and the Department of Health and Rehabilitative Services. The revocation was effective June 1, 1994. The Settlement Agreement stipulated that the Petitioner could reapply for registration as a septic tank contractor upon the expiration of the two (2) years stipulated in the agreement under the rules in effect at the time of the new application. The Settlement Agreement was signed by Petitioner and by Petitioner’s counsel. On September 6, 1996, the Petitioner issued its denial of the Petitioner’s instant application on the grounds that he failed to meet the qualifications listed in Rule 10D- 6.072(3)(d)(e)(f), Florida Administrative Code. It is uncontroverted that the Petitioner had his prior registration as a septic tank contractor revoked and that he was adjusted guilty of attempted felony littering in a case-related septic tank contracting.
Recommendation Based upon the foregoing Findings of Fact and Conclusions of Law set forth herein, it is RECOMMENDED: That the Petitioner’s application for registration as a septic tank contractor be denied because he was convicted of a crime involving contracting and his license had been revoked within five (5) years prior to his application. DONE AND ENTERED this 17th day of November, 1997, in Tallahassee, Leon County, Florida. COPIES FURNISHED: Jerry D. Thompson 500 Walker Street Holly Hill, Florida 32117 Charlene Petersen, Esquire Chief Legal Counsel Department of Health 420 Fentress Boulevard Daytona Beach, Florida 32114 Angela T. Hall, Agency Clerk Department of Health 1317 Winewood Boulevard Building 6 STEPHEN F. DEAN Administrative Law Judge Division of Administrative Hearings The DeSoto Building 1230 Apalachee Parkway Tallahassee, Florida 32399-3060 (904) 488-9675 SUNCOM 278-9675 Fax Filing (904) 921-6847 Filed with the Clerk of the Division of Administrative Hearings this 17th day of November, 1997. Tallahassee, Florida 32399-0700 Dr. James Howell, Secretary Department of Health 1317 Winewood Boulevard Building 6, Room 306 Tallahassee, Florida 32399-0700 Pete Peterson, Esquire Department of Health 1317 Winewood Boulevard Building 6, Room 102E Tallahassee, Florida 32399-0700
The Issue At issue in DOAH Case No. 04-4333 is whether Respondent committed the two violations of Florida Administrative Code Rule 64E-6.022 alleged in the citation issued on September 29, 2004, and, if so, whether the imposition of a $1,000.00 fine was properly imposed. At issue in DOAH Case No. 05-0695 is whether Respondent committed the three violations alleged in the Amended Administrative Complaint issued on February 21, 2005, and, if so, whether his septic tank contractor registration should be revoked or some lesser penalty imposed.
Findings Of Fact The Department is the state agency charged with enforcing the statutory provisions pertaining to the practice of septic tank contracting in Florida pursuant to Chapter 489, Part III, and Section 381.0065, Florida Statutes (2004). At all times relevant to this proceeding, Respondent Matt Beebe, was a registered septic tank contractor, having been issued registration number SR0971283, and was the qualifying contractor for his business, Southern Sanitation, Inc. ("Southern Sanitation"), having been issued registration number SA0970864. On June 7, 2001, Mr. Beebe was cited for installing a septic system without a permit, in violation of Florida Administrative Code Rule 64E-6.022, and paid a fine of $500.00 without contest. At all times relevant to this proceeding, Mr. Beebe also operated a septage disposal service business under the Southern Sanitation name, having been issued operating permit number 11-QN-0054. Improper Septage Disposal and Sanitary Nuisance On September 29, 2004, Kenneth Rech, the Department's environmental health and engineering director for Collier County, received a telephone complaint that a Southern Sanitation septage hauling truck had been seen emptying its contents onto a vacant lot at 295 Brandy Lane in Naples. Mr. Rech and his assistant, James Miller, drove out to the location to investigate the complaint. When he arrived at the location, Mr. Rech first spoke to the complainant, who lived across the street from the vacant lot. The complainant estimated that the Southern Sanitation truck left the lot about 20 minutes before Mr. Rech arrived. Mr. Rech and Mr. Miller investigated the site. Mr. Rech described the area containing the dumped contents of the truck as a low-lying wetland. The property was about ten acres in size. The owner kept horses on the lot. Mr. Rech testified that there was a strong smell of septage, though the dumped contents were light gray in color. Raw septage is generally black. Based on the smell, Mr. Rech concluded that the dumped contents included septage mixed with some other material. Mr. Rech telephoned Erin Kurbec to meet him at the dump site. Ms. Kurbec is a Department employee responsible for oversight of septage hauling and disposal businesses. Ms. Kurbec in turn phoned Mr. Beebe and asked him to come to the site. Mr. Rech testified that Mr. Beebe was "very agitated" when he arrived at the dump site, calling Ms. Kurbec a "liar," and protesting that the Department did not have the right to ask for his company's hauling logs. Because of Mr. Beebe's aggressive behavior, Mr. Rech phoned to request a Sheriff's deputy to come to the site. Mr. Beebe conceded that he was somewhat agitated because Ms. Kubec asked him to come to the site, but would not tell him why she wanted to see his truck. She would only say that it was a "spot check," which Mr. Beebe did not believe. By the time the Sheriff's deputy arrived, the situation had calmed down. Mr. Beebe told Mr. Rech that he had dumped approximately 3,000 gallons of "drillers' mud" on the site. Drillers' mud, or bentonite clay, is a colloidal clay sold under various trade names that forms a slick slurry, or gel, when water is added. The appearance of the material dumped at the site was consistent with that of drillers' mud. Mr. Beebe testified that the owner of the vacant lot asked him to dump the drillers' mud to fill in a low-lying, hard to reach area of the property. The liquid-like consistency of the drillers' mud made it ideal for filling this difficult portion of the property. Mr. Beebe's testimony as to having permission to dump materials on the property is credited. Mr. Rech took two samples of the dumped material from a pooled area about six inches deep. He used sterile sample equipment and containers. Because Mr. Beebe had alerted him to the possibility that there could be horse manure under the dumped material, Mr. Rech was careful to scoop the contents from the top of the dumped material. Mr. Rech provided one of the samples to Mr. Beebe to allow Mr. Beebe to have a laboratory of his choice analyze the material. Mr. Rech sent the other sample to the Department's Tampa laboratory, which found the sample to contain a fecal coliform count of 4,800 colonies per gram. The laboratory's report was stamped with the disclosure stating, "Sample does not meet the following NELAC requirements: 1) exceeds 6 hr. hold time; 2) this matrix is not certified under NELAC." NELAC is the National Environmental Laboratory Accreditation Conference, a voluntary association of state and federal agencies, the purpose of which is to establish and promote mutually acceptable performance standards for the operation of environmental laboratories. NELAC certifies environmental laboratories such as the Department's Tampa facility, which was not certified for solid matrices such as the sample provided by Mr. Rech. Dr. Philip Amuso is the director of the Department's Tampa laboratory. Dr. Amuso testified as to the testing procedures and the disclosure statement included on the laboratory report. He concluded that neither of the disclosures affected the validity of the fecal coliform count found in the sample. Dr. Amuso testified that the applicable testing standard calls for a sample to be analyzed for fecal coliform within six hours of the sample collection time. The sample in question was not tested within six hours. However, Dr. Amuso testified that the longer a sample is held, the lower the fecal coliform count will be, because the fecal coliform colonies tend to die off over time. Thus, Dr. Amuso testified that the fecal coliform count in the sample was likely understated, due to the failure to analyze the sample within six hours. Dr. Amuso testified that his laboratory chose to classify the sample as solid. The Tampa laboratory was required to note on its report that it is not NELAC-certified for solid matrices. However, Dr. Amuso testified that the classification of the sample had no impact on the analysis performed or the validity of the result. He explained that the laboratory could have classified the sample as a non-potable liquid, a matrix for which the Tampa laboratory is NELAC-certified, and the same analysis would have been performed and would have yielded the same result. Mr. Beebe forwarded his sample of the dumped material to Sanders Laboratories, Inc. ("Sanders"), a private environmental testing service. The Sanders laboratory classified the sample as a non-potable liquid and performed its analysis within six hours of the sample's collection. The Sanders laboratory report dated September 30, 2004, found the fecal coliform count to be 1,600,000 colonies per 100 milliliters. Placed in comparable terms to the Tampa laboratory's report, this sample showed a fecal coliform count of 16,000 colonies per gram, or about three times higher than the Tampa laboratory's sample. Dr. Amuso attributed this higher reading to the fact that Sanders ran its test within six hours of collection. Dr. Amuso testified that the fecal coliform count of 4,800 colonies per gram found in the Tampa laboratory's sample constituted "pretty significant" contamination. Mr. Rech testified that a count of 4,800 colonies per gram is about one-half of the count found in raw, untreated septage from a septic tank, and that such a count is "bad" in terms of public health significance. Mr. Rech testified that the fecal coliform count in the Sanders sample was "in the range" for raw untreated septage. Mr. Rech stated that the laboratory analyses led to the conclusion that there was a substantial amount of untreated septage mixed with the drillers' mud in the dumped materials. He concluded there was more septage than could reasonably be attributed to residue from a previous dump of septage in Mr. Beebe's truck. He added that it would be impossible to clean the tank of a septage disposal truck sufficiently to prevent fecal contamination of a subsequent non-septage load. Mr. Beebe conceded that Mr. Rech told him that he should not use a septage hauling truck for any other kind of load, especially where that load would be dumped on the ground. Before leaving the dump site on September 29, 2004, Mr. Rech and Ms. Kurbec handed Mr. Beebe the citation for failure to properly treat or dispose of septage and the creation or maintenance of a sanitary nuisance. The citation directed Mr. Beebe to pay a fine of $500.00 for each of the two violations. Mr. Rech testified that he and Ms. Kurbec were able to conclude from their on-site observations that Mr. Beebe had improperly disposed of septage and had created a sanitary nuisance. Mr. Rech stated that the subsequent laboratory analysis served to confirm those conclusions. Mr. Rech testified that untreated septage consists of human waste containing high levels of fecal coliform and viruses, bacteria, and parasites that cause a wide range of gastrointestinal and neurological conditions in humans. Mr. Rech stated that untreated septage dumped anywhere other than at a properly regulated disposal site constitutes a public health nuisance. He noted that the materials were dumped by Mr. Beebe within roughly 100 feet of residential drinking water wells. Mr. Beebe admitted that he dumped the contents of his disposal truck on the vacant lot, though he denied that it contained septage. He theorized that the high fecal coliform counts in the laboratory analyses were caused by animal manure beneath the drillers' mud that he dumped on the property. Dr. Amuso conceded that no testing had been performed to establish the ambient level of coliform on the property, and further conceded that the laboratory tests do not distinguish human from animal feces in measuring the coliform count. However, as noted above, Mr. Rech knew that there were animals on the property and carefully took his sample from the top of the dumped material. Mr. Rech testified that the strong smell of septage, and the high coliform count found by the subsequent laboratory analyses left no doubt that untreated human waste had been dumped on the property by Mr. Beebe. The Department established, by clear and convincing evidence, that Mr. Beebe dumped a mixture of drillers' mud and untreated septage on the lot at 295 Brandy Lane in Naples. Holding Tank On or before January 6, 2005, Mr. Beebe placed a 900-gallon domestic wastewater holding tank into a pre-dug hole at the newly built residence of Edward Ehlen at 616 Crescent Street on Marco Island. Mr. Beebe did not dig the hole, nor did he connect the holding tank to Mr. Ehlen's house. Mr. Ehlen testified that he contracted with the City of Marco Island in July 2004 to connect his new residence, an $800,000 house, to the city sewer system. The connection was to be completed no later than November 2004, when Mr. Ehlen and his family expected to take occupancy of the house. The city did not complete the connection and, therefore, allowed Mr. Ehlen to install a holding tank to be used until the sewer connection was completed. After the holding tank was installed, the city inspected the tank and gave Mr. Ehlen a temporary certificate of occupancy. On January 6, 2005, after Mr. Ehlen and his family had moved into their house, the Department discovered that the Ehlen home was using a holding tank to collect its wastewater. On January 7, 2005, the Department issued to Mr. Ehlen an "Official Notice to Correct and Abate a Sanitary Nuisance," finding that Mr. Ehlen was in violation of "Florida Statutes Chapters 381 and 386" because "plumbing discharge from your home is connected to a sewage holding tank which has not been permitted or inspected by this department." The Notice also provided, in relevant part: You are hereby directed to correct this condition by complying with all the conditions listed below. Apply for a "temporary" Holding Tank permit by close of business on Monday, January 10, 2005. [This permit will be valid for a maximum of 120 days, Permit fee is $185.00] Apply for an abandonment permit for the temporary holding tank by close of business Monday, January 10, 2005. [This permit will be valid for a maximum of 120 days. Complete tank removal will be required within 10 days of hook up to public sewer. Permit fee is $40.00] Have a licensed septic contractor excavate the holding tank for inspection of all connections and seals by this department by Wednesday, January 12, 2005. Sign and maintain a pump-out agreement with a licensed septage hauler until the temporary holding tank is properly abandoned and inspected by this department. Provide a copy of this agreement to the department by Wednesday, January 12, 2005. [Minimum required pump-out frequency to be every other day]. Complete hookup to Marco Island Utilities sewer system within 120 days of receipt of this notice. Failure to comply may result in administrative and/or civil enforcement action, including administrative fines of up to $500 per day per violation of law. On January 12, 2005, the Department issued a 120-day temporary permit to Mr. Ehlen for his holding tank. Also on January 12, 2005, Mr. Ehlen signed a contract with Southern Sanitation pursuant to which Mr. Beebe's company agreed to pump out the holding tank three times per week. Mr. Beebe conceded that he did not obtain a permit from the Health Department before he placed the holding tank in the hole on Mr. Ehlen's property. Mr. Beebe relied on Mr. Ehlen's statement that the City of Marco Island had approved the installation of the holding tank. Florida Administrative Code Rule 64E-6.0101(7) provides that a construction permit must be obtained before the placement or installation of any holding tank. The Department established, by clear and convincing evidence, that Mr. Beebe placed a 900-gallon domestic wastewater holding tank into a pre-dug hole at the Ehlen's residence without obtaining a Department permit. Mr. Beebe's good faith belief that Mr. Ehlen had obtained approval for the placement of the tank is noted as a mitigating factor, but cannot operate as a defense for a registered septic tank contractor's admitted failure to confirm the status of any permit with the Department prior to commencing work on the project. Collection and Hauling Log Mr. Beebe's annual operating permit from the Department authorizes him to pump septage from septic tanks and holding tanks and haul it to an approved treatment site for disposal and treatment. Florida Administrative Code Rule 64E-6.010(7)(e) requires a septage hauler to maintain a collection and hauling log "at the treatment site or at the main business location" and to retain that log for a period of five years. The rule lists the following items for inclusion in the log: Date of septage or water collection; Address of collection; Indicate whether the point of collection is a residence or business and if a business, the type of business; Estimated volume, in gallons, of septage or water transported; Receipts for lime or other materials used for treatment; Location of the approved treatment facility; Date and time of discharge to the treatment facility; and Acknowledgement from treatment facility of receipt of septage or waste. On September 29, 2004, the date on which the Department investigated Mr. Beebe's dumping of drillers' mud and sewage on the lot at 295 Brandy Lane in Naples, the Department requested that Mr. Beebe provide his septage collection and hauling log. On September 30, 2004, Mr. Beebe faxed to the Department a single-page, typed document titled, "RE: Southern Sanitation, Inc. Truck Log for Trucks 1 and 2." The document stated that on September 29, 2004, "Truck #1" transported 3,000 gallons of "Well Drillers Mud" from Southern Well Drillers Services drilling site and disposed of it at 295 Brandy Lane. The document stated that "Truck #2" did not haul materials on September 29, 2004. Mr. Rech testified that this document did not satisfy the rule criteria for collection and hauling logs. He noted that this was not a log kept by the drivers of the trucks, but merely a statement from Mr. Beebe attesting to what the trucks had hauled on a single day. Mr. Rech also pointed out that the Department had inspected and authorized Mr. Beebe to haul septage in two trucks identified by their vehicle identification numbers, but that Mr. Beebe's single-page "log" provided no information specifically identifying the trucks in question. On February 3, 2005, the Department sent a letter to Mr. Beebe requesting that he produce, among other documentation, "your original collection and hauling logs for all domestic sewage and food establishment sludge and/or septage you collected and disposed of from January 1, 2004 through February 2, 2005." On February 11, 2005, Mr. Beebe responded to the Department's request, providing copies of "Septic Receiving Logs" maintained by the North County Water Reclamation Facility ("NCWRF"), the Collier County wastewater facility at which Mr. Beebe disposed of his loads. There were log pages for January through June 2004, and October through December 2004. The logs included the dates of disposal, the number of gallons and type of waste in the load (septic or grease), and the signature of the Southern Sanitation driver who dropped off the load. On March 8, 2005, Mr. Beebe submitted to the Department supplemental information covering January 2005. It includes a typed "Pump Job List" for January 2005, prepared on March 3, 2005. The list contains dates, addresses, and approximate gallons collected, including eight entries for pumping out Mr. Ehlen's holding tank. Individual trucks were not identified on this list. The supplemental information also included an NCWRF Septic Receiving Log for January 2005. Mr. Beebe testified that the Department had never asked him for an accounting during the eight years he has operated his business and that the Department did so in this case only after he contested the allegations in the Brandy Lane dumping case. Mr. Beebe appeared to believe that the Department was acting punitively in requesting documents that Mr. Beebe, as the owner of a permitted septage disposal business, was required to keep. Mr. Beebe did not contest the apparent fact that he did not keep collection and hauling logs for his trucks in the normal course of business. Such documentation as he provided was insufficiently detailed to meet the requirements of Florida Administrative Code Rule 64E-6.010(7)(e), and in some instances was cobbled together well after the fact in order to provide the Department with some documentation of Southern Sanitation's activities. Mr. Rech testified that the Department requires accurate logs of collections and disposals to allow it to monitor compliance and investigate complaints. An accurate, detailed, and contemporaneously-created log would have allowed the Department to discover what Mr. Beebe's truck had collected and dumped prior to the Brandy Lane dumping incident and would have allowed the Department to reconcile the amounts of septage collected by Mr. Beebe from January 2004 through February 2005, with the amounts of septage Mr. Beebe properly disposed of during the same period. The Department established, by clear and convincing evidence, that Mr. Beebe did not maintain a septage collection and hauling log as required by Florida Administrative Code Rule 64E-6.010(7)(e). Improper disposal of septage The terms of Mr. Beebe's septage disposal service permit required him to dispose of his collected septage at the NCWRF. Dale Waller, the plant manager of the NCWRF, testified as to the procedures followed by sewage haulers at the facility. Mr. Waller testified that the facility has a computer capable of generating reports as to the quantity of disposals made by haulers, but that the computer system often does not operate correctly. Therefore, the facility's chief means of monitoring disposals is the "Septic Receiving Logs" discussed above. The Septic Receiving Log requires the hauler to record the date of disposal, whether the disposal consisted of septage or grease, the amount of disposed material in gallons, and the driver's signature and printed name. The number of gallons disposed is shown on a calibrated gauge when the waste is pumped out of the truck. Mr. Waller testified that this gauge is accurate within five per cent of the actual amount pumped. The county sends invoices each month to the hauler, based on the number of gallons and the type of waste disposed of at the facility. The Septic Receiving Log is maintained in the foyer of the NCWRF building, with a monthly sheet for each hauling company that uses the facility. No NCWRF employee monitors the haulers as they make their log entries. Mr. Waller testified that it is essentially an honor system for the haulers. Due to computer problems, the NCWRF had no computer records of disposals for the month of January 2005. The Septic Receiving Log for Southern Sanitation for that month showed six entries totaling 11,908 gallons of septage and grease, plus two early January 2005 entries of 3,450 gallons that were placed on the December 2004 log, for a total of 15,358 gallons. Mr. Waller testified that in March 2005, Mr. Beebe submitted a revised Septic Receiving Log for Southern Sanitation for the month of January 2005. Mr. Beebe also provided this revised log to the Department as part of his March 8, 2005, supplemental information for the month of January 2005. This revised log listed three additional disposals of septage in the month of January 2005: 2,550 gallons on January 17; 2,000 gallons on January 24; and 1,700 gallons on January 28. These additional 6,250 gallons brought the reported total disposals of septage and grease for January 2005 to 21,608 gallons. The NCWRF declined to accept the revised Septic Receiving Log as an official record of Southern Sanitation's disposals at the facility for the month of January 2005, because the NCWRF could not verify the additional disposals. Mr. Beebe was billed only for those disposals documented on the original Septic Receiving Log kept at the facility. As part of the March 8, 2005, submission of supplemental information, Mr. Beebe provided to the Department a "pump job list" for January 1 through 28, 2005. This list indicated that Southern Sanitation collected between 21,000 and 22,600 gallons of wastewater during the period specified, a number that roughly corresponds to the total number of gallons reported by Mr. Beebe in his revised Septic Receiving Log for the month of January 2005. At the hearing, the Department contended that because Mr. Beebe reported collecting between 21,000 and 22,600 gallons of waste, but could only verify the proper disposal of 15,358 gallons of waste, Mr. Beebe must have improperly disposed of at least 5,600 gallons and as much as 7,200 gallons of waste. In a similar fashion, the Department examined the amounts that Mr. Beebe reported pumping from Mr. Ehlen's holding tank, compared those amounts to the Ehlen household's water usage for the month of January 2005, and concluded that Mr. Beebe further underreported the amount of waste collected that month and, therefore, must have improperly disposed of even more than 5,600 to 7,200 gallons of waste. Mr. Beebe was forthright regarding the issues in these cases, even when his testimony was against his own interests. In light of his overall credibility, Mr. Beebe's denial that he made any improper disposals of waste is credited. No evidence was presented to show that Mr. Beebe actually made these improper disposals. The Department's contention was a surmise derived from discrepancies in Mr. Beebe's reports of collections and disposals. Based on all the evidence, the undersigned finds that the discrepancies in the reports were more likely due to Mr. Beebe's poor record-keeping and his after-the-fact efforts to create records complying with Florida Administrative Code Rule 64E-6.010(7)(e), rather than any illegal dumping of waste. The Department failed to establish by clear and convincing evidence that Mr. Beebe improperly disposed of septage during the month of January 2005.
Recommendation Based on the foregoing Findings of Fact and Conclusions of Law, it is RECOMMENDED that Petitioner, the Department of Health, enter a final order imposing a $1000.00 fine for the violations described above, relating to DOAH Case No. 04-4333, and imposing a fine of $1,500.00 and a 90-day suspension of Respondent's septage disposal operating permit for the violations described above, relating to DOAH Case No. 05-0695. DONE AND ENTERED this 7th day of July, 2005, in Tallahassee, Leon County, Florida. S LAWRENCE P. STEVENSON Administrative Law Judge Division of Administrative Hearings The DeSoto Building 1230 Apalachee Parkway Tallahassee, Florida 32399-3060 (850) 488-9675 SUNCOM 278-9675 Fax Filing (850) 921-6847 www.doah.state.fl.us Filed with the Clerk of the Division of Administrative Hearings this 7th day of July, 2005. COPIES FURNISHED: Michael F. Kayusa, Esquire Post Office Box 6096 Fort Myers, Florida 33911 Susan Mastin Scott, Esquire Department of Health 2295 Victoria Avenue, Room 206 Fort Myers, Florida 33901 R.S. Power, Agency Clerk Department of Health 4052 Bald Cypress Way, Bin A02 Tallahassee, Florida 32399-1701 Timothy M. Cerio, General Counsel Department of Health 4052 Bald Cypress Way, Bin A02 Tallahassee, Florida 32399-1701
The Issue The issue in this case is whether Respondent, Larry C. Garner, should be fined $500 for misstating the size of a septic tank and drain field.
Findings Of Fact Respondent, Larry C. Garner, is the licensed septic tank contractor who owns and operates A. Carver Septic Tank. (The Citation for Violation erroneously referred to the company as “E. Carver Septic Tank,” but the error was corrected without objection at final hearing. There was no evidence to support Respondent’s suggestion that the Department may have taken disciplinary action against him because it erroneously thought Respondent was another licensee.) On December 6, 2001, an employee of Respondent pumped out a septic tank and measured a drain field located at 847 Matthews Road, Maxville, Florida. The resident there wanted to enlarge her residence and needed Respondent's services in order to obtain Department approval of the existing septic tank system for the enlarged residence. After services were provided, Respondent's office gave the resident a receipt stating that Respondent's company had pumped out a 900 gallon septic tank and that the drain field measured 360 square feet. (Respondent's office actually dealt with the resident's adult daughter.) Respondent's office staff also prepared Form 4015 (a Department form entitled “Onsite Sewage Treatment and Disposal System Existing System and System Repair Evaluation”) and gave it to the resident for use in getting approval of the system for the enlarged residence. The form stated that the septic tank was 900 gallons and that the drain field was 360 square feet. When the resident applied for approval of her septic tank system for her enlarged residence, the Department inspected the system and found that the septic tank actually was 750 gallons and the drain field actually was only approximately 110 square feet. The Department issued the Citation for Violation based on the magnitude of the discrepancy. Respondent denied that he personally had any contemporaneous knowledge of the services provided by his employee or the receipt of Form 4015 prepared by his office, and there was no evidence that he did. Respondent personally investigated after issuance of the Citation for Violation. At final hearing, Respondent questioned whether the Form 4015 actually stated that the septic tank was 900 gallons. From the handwriting on the form itself, it appears possible that the number could read 700, not 900. But based on the written receipt, which either was prepared contemporaneously with the Form 4015 or was the basis for preparation of the Form 4015 by Respondent's office staff, the greater weight of the evidence was that the Form 4015 stated and was intended to state 900 gallons as the size of the septic tank. As further support for this finding, Respondent himself testified to a conversation he had with his employee during which the employee explained that he sized the septic tank at 700 gallons based on its apparent depth and Respondent admonished him that the employee knew better--i.e., knew it was necessary to measure height, width, and depth to accurately measure the size of a septic tank. Respondent also attempted to explain how his employee may have made a forgivable error in measuring the drain field. According to the Form 4015, the employee measured the drain field as a rectangular bed, 12 feet by 30 feet. Actually, the drain field consists of two trenches (one 26 feet long and the other 29 feet long), which the Department's inspector measured as being two feet wide. Respondent testified that the drain field began at a distribution box and was approximately ten feet wide within a few feet of the distribution box. Respondent testified that it would be easy to incorrectly assume that the approximate ten-foot width continued as a bed for the entire length of the drain field, as his employee apparently did. However, the greater weight of the evidence was that the employee's error was not reasonable; to the contrary, to determine the configuration and size of a drain field, it is necessary to probe the ground at more than just one distance close to the distribution box. When Respondent himself went to the site to investigate the allegations against him, he probed both near the distribution box and further away southeast of the distribution box. He testified that he found solid rock ten feet in width near the distribution box; to the southeast, his probing revealed a trench which Respondent measured at between three and a half and four feet in width. Based on those measurements, Respondent assumed two trenches approximately 30 feet long and four feet in width each, for a total of approximately 240 square feet. It is difficult to reconcile Respondent’s testimony as to the width of the southeast trench with the testimony of the Department's inspector. The Department's inspector probed approximately ten feet and 20 feet from the septic tank and found two-foot wide trenches in four different places. The Department's inspector also testified without contradiction in response to Respondent's questions on cross-examination that backhoes used at the time this drain field was installed in 1973 generally had two-foot wide excavation buckets. Based on the greater care taken by the Department's inspector in measuring the drain field, and the kind of backhoe in general use in 1973, it is found that the Department's inspector's measurements were more accurate. Even if Respondent's measurements were accurate, and the Department inspector's were inaccurate, the measurements recorded on the receipt and on Form 4015 still would have been seriously overstated. While not seriously disputing the inaccuracy of the Form 4015 submitted in this case, Respondent stated "anyone can make a mistake" and that the Department should have asked Respondent to re-check the measurements instead of issuing a citation, especially in view of Respondent's disciplinary record in 29 years in the business in Clay County. (Respondent testified that his only "issues in Tallahassee" were one incident--not fully explained--involving a cow on someone's property and another when he had someone take a re- certification examination for him at a time when his mother was ill. The Department did not controvert this testimony. As already mentioned, there was no evidence to support Respondent's initial suggestion that the Department may have taken disciplinary action against him because it erroneously thought he was another licensee.) But the Department's witness testified that issuance of the citation was appropriate and consistent with agency policy because of the magnitude of the discrepancies on the Form 4015. Respondent testified that the employee involved in this case was his stepson, who has worked for Respondent for 14 years, since he was 11 years old, seven to eight years as a full-time employee. Respondent also testified that he recently fired his stepson, but the reasons for firing him were not directly related to his conduct in this case. Respondent also testified that he felt compelled to insist on a hearing although he knew the Form 4015 was inaccurate because he perceived the Department to be acting in this case as if it had "absolute power" over him. He apparently viewed his request for a hearing as a necessary challenge to government's assertion of "absolute power" over him.
Recommendation Based upon the foregoing Findings of Fact and Conclusions of Law, it is RECOMMENDED that the Department of Health enter a final order finding Respondent guilty as charged and imposing a fine in the amount of $500. DONE AND ENTERED this 24th day of May, 2002, in Tallahassee, Leon County, Florida. ______________________________ J. LAWRENCE JOHNSTON Administrative Law Judge Division of Administrative Hearings The DeSoto Building 1230 Apalachee Parkway Tallahassee, Florida 32399-3060 (850) 488-9675 SUNCOM 278-9675 Fax Filing (850) 921-6847 www.doah.state.fl.us Filed with the Clerk of the Division of Administrative Hearings this 24th day of May, 2002. COPIES FURNISHED: Dr. John O. Agwunobi, Secretary Department of Health 4052 Bald Cypress Way, Bin A00 Tallahassee, Florida 32399-1701 William W. Large, General Counsel Department of Health 4052 Bald Cypress Way, Bin A02 Tallahassee, Florida 32399-1701 R. S. Power, Agency Clerk Department of Health 4052 Bald Cypress Way, Bin A02 Tallahassee, Florida 32399-1701 John D. Lacko, Esquire Department of Health 420 Fentress Boulevard Daytona Beach, Florida 32114 Larry C. Garner 13950 Normandy Boulevard Jacksonville, Florida 32221
The Issue The issue addressed in this proceeding is whether Respondent should be fined for violating provisions of Chapters 381, 386 and 489, Florida Statutes, governing septic tank installation and licensure.
Findings Of Fact On August 3, 1989, and again in March, 1992, Respondent was hired by Janet Thompson to perform septic tank work on her septic tank system located at her home at 3168 Pins Lane, Gulf Breeze, Santa Rosa County, Florida. Her system was backing up into her house. Ms. Thompson contacted Mr. Burkett through his advertisement for Working Man Septic Tank in the Southern Bell Yellow Pages. Mr. Burkett recommended that a new drainline or finger be added to her septic system. Mr. Burkett did put in a new finger. However, the new finger was incorrectly installed, in that the drainline exceeded the maximum allowable width and did not have the minimum depth of aggregate in violation of the Rules of the Department regarding the installation of drainlines for septic tank systems. Mr. Burkett's work seemed to solve Ms. Thompson's backup problem. However, a few months later her septic tank system began backing up again. Ms. Thompson again called Mr. Burkett to come and fix the problem. Mr. Burkett recommended another drainline in an "L" shaped configuration. Mr. Burkett installed the new finger. However, he again installed the line incorrectly and violated the Department's Rules, in that the drainline exceeded the maximum allowable width and did not have the minimum depth of aggregate. Ms. Thompson's septic tank problem was corrected for a few months and then began backing up once more. Ms. Thompson called another contractor who finally solved the problem by properly installing an extensive drainline system by building the low area of the drainfield and utilizing three truckloads of aggregate. In May, 1990, William Davenport hired Respondent to do some preventive installation of a new drainfield to the septic tank system located at his home at 6220 East Bay Boulevard, Gulf Breeze, Santa Rosa County, Florida. Mr. Burkett only performed part of the work for which he was hired. The work Respondent did perform was incorrect and violated the Department's Rules regarding the installation of drainfields and lines for septic tank systems. Specifically, the work performed by Respondent was incorrect in that the drainfield exceeded the maximum allowable width, no barrier of building paper or other suitable material was installed to protect the infiltration bed and the aggregate did not meet the minimum depth required. Rules 10D-6.056(4)(a), (d) and (e), Florida Administrative Code. Finally, throughout the time period of the repair work on the Thompson and Davenport properties Respondent was not registered or licensed by the Department to perform such services and was advertising to provide such services under the name "Working Man Septic Tank Co." in the Southern Bell Yellow Pages. Both the lack of a registration and the advertisement of an unlicensed business violate the Rules of the Department. Rule 10D-6.075(4)(a), Florida Administrative Code.
Recommendation Based upon the foregoing Findings of Fact and Conclusions of Law it is, accordingly, RECOMMENDED, that the Department impose on Respondent a fine of $2,000.00. DONE and ORDERED this 9th day of November, 1994, in Tallahassee, Florida. COPIES FURNISHED: Frank C. Bozeman, III Asst. District Legal Counsel D H R S 160 Governmental Center Pensacola, FL 32501 Kenneth P. Walsh Attorney at Law P. O. Box 1208 Shalimar, FL 32505 Robert L. Powell, Clerk Department of Health and Rehabilitative Services 1323 Winewood Boulevard Building One, Room 407 Tallahassee, FL 32399-0700 Kim Tucker General Counsel Department of Health and Rehabilitative Services 1323 Winewood Boulevard Building One, Room 407 Tallahassee, FL 32399-0700 DIANNE CLEAVINGER Hearing Officer Division of Administrative Hearings The DeSoto Building 1230 Apalachee Parkway Tallahassee, Florida 32399-1550 (904) 488-9675 Filed with the Clerk of the Division of Administrative Hearings this 9th day of November, 1994.
The Issue Whether the Petitioner is qualified for licensure as a septic tank system contractor.
Findings Of Fact The Petitioner applied for Septic Tank Contractor Registration on or about June 1, 1993. Mr. Gerald Briggs, Environmental Health Specialist III for the Department, notified the Petitioner that his application was not complete on or about July 7, 1993, and returned the Petitioner's application to the Petitioner. In November 1993, the Petitioner refiled his application with the Department. By letter dated December 9, 1993, the Department notified the Petitioner of its decision to deny his application for septic tank contractor's registration because the Petitioner lacked the required three years of active experience as a worker who has learned the trade as an apprentice under a registered septic tank contractor. William A. Kerce, a registered septic tank contractor in Florida, testified at the hearing. He stated that he had employed the Petitioner prior to the Petitioner's graduation from high school in 1985, and continued to employ him up until he sold the business to Donald Rose. The Petitioner's duties for installation of new septic tanks and for repairs of existing systems were to dig up an area, prepare it to install a septic tank in the ground, prepare the drainfield, and recover the tank and drainfield with soil. In addition, Mr. Kerce used the Petitioner to assist him in pumping septic tanks. Mr. Kerce stated that he did not consider the Petitioner an employee, but considered him an independent contractor. Mr. Kerce would have had to pay social security and provide worker's compensation benefits if he had considered the Petitioner an employee. Mr. Kerce provided all the materials and equipment used on the job. Mr. Kerce used the Petitioner's services five or six days a week for well over three years. Petitioner did not work for Mr. Kerce when Mr. Kerce did not have work to do, about two weeks per year. Mr. Kerce paid the Petitioner by the job, $200-$300 for installing a system, and $15-20 for helping him pump a system. The Petitioner worked for Mr. Kerce, except when he was working for another septic tank contractor doing the same type of work. If the Petitioner was working for another man, Mr. Kerce waited and scheduled his work until the Petitioner was available. While Mr. Kerce was not present on the job constantly, Mr. Kerce did supervise and approve all work done by the Petitioner. He was required by law to do so. Mr. Kerce sold his business to Donald Rose in 1992. To Mr. Kerce's knowledge, Mr. Rose continued to use the Petitioner. Mr. Rose could not get qualified as a contractor with the Department. As a result, Mr. Kerce had to step back in and run the business. The Petitioner assisted Mr. Rose in installing unpermitted systems. When confronted, the Petitioner assisted in the investigation of Mr. Rose, under threat of prosecution. As a result, the court withheld adjudication in the Petitioner's case and placed him on probation which he has not completed. The Petitioner was employed by Rotor Rooter in Jacksonville, Florida, for six months, installing and repairing septic systems. The Petitioner has been employed by AA Septic since April 15, 1994. The Petitioner took steps in June, 1993, to start a septic tank business as C&J, including listing in the Yellow Pages. However, his application was not approved. He did install a system for Eleanor Rake at about that time without a permit; however, he later returned Ms. Rake's money when confronted by the authorities. The Petitioner was on probation when he did the work for Ms. Rake.
Recommendation Based upon the consideration of the facts found and the conclusions of law reached, it is, RECOMMENDED: That the Department deny the Petitioner certification until he completes his probation for violations of laws directly related to installation of septic systems; and further, that upon the completion of that probation and reapplication, the Department register the Petitioner, who has established that he met the work experience requirements. DONE and ENTERED this 27th day of June, 1994, in Tallahassee, Florida. STEPHEN F. DEAN, Hearing Officer Division of Administrative Hearings The DeSoto Building 1230 Apalachee Parkway Tallahassee, Florida 32399-1550 (904) 488-9675 Filed with the Clerk of the Division of Administrative Hearings this 27th day of June, 1994. APPENDIX TO RECOMMENDED ORDER CASE NO. 94-0954 The following findings were adopted or rejected for the reason stated: Respondent's Findings Recommended Order Paragraph 1 Paragraph 1 Paragraph 2 Paragraph 2 Paragraph 3 Paragraph 3, 4 Paragraph 4 Subsumed in paragraph 4 and Preliminary Statement. Paragraph 5 Subsumed in paragraphs 5 and 6 which are based upon best evidence. Paragraph 6 Subsumed in paragraphs 8 - 11, which are based on best evidence. Paragraph 7 Subsumed in Preliminary Statement. COPIES FURNISHED: Edward Jackson, Esquire 515 W. Adams Street Jacksonville, FL 32202 Teresa Donnelly, Esquire Department of Health and Rehabilitative Services 1000 N.E. 16th Avenue Building H Gainesville, FL 32601 Robert L. Powell, Clerk Department of Health and Rehabilitative Services 1323 Winewood Boulevard Tallahassee, FL 32399-0700 Kimberly J. Tucker, General Counsel Department of Health and Rehabilitative Services 1323 Winewood Boulevard Tallahassee, FL 32399-0700
The Issue The issue in this case is whether Respondent created a sanitary nuisance by installing drainfield pipes too far apart in a septic tank drainfield and failing to seal the lid to a septic tank, failing to call for a required inspection before covering an onsite sewage disposal system, and engaging in gross misconduct by assaulting two of Petitioner's employees.
Findings Of Fact Respondent is registered with Petitioner as a septic tank contractor and authorized to provide septic tank contracting services. On May 4, 1994, pursuant to a previously issued permit, Respondent completed the installation of a new drainfield at 204 West DelMonte Avenue in Clewiston. He asked Petitioner's office for an inspection for approval to cover the system. Jim Rashley, an environmental specialist employed by Petitioner, inspected the system on the morning of May 4. No one was at the site during the inspection. Mr. Rashley discovered a violation concerning the type of header pipe. He also discovered that the drain lines were more than 36 inches apart and 18 inches from the side of the field. Mr. Rashley determined that the drainfield pipes were three feet and four inches apart. Examining the septic tank itself, which Respondent had pumped, Mr. Rashley found that the lid had not been properly resealed, which would allow rain or dirt to enter the tank or effluent to escape from the tank if the drainfield failed. Returning to his office, Mr. Rashley informed his supervisor, Steve Havig, that he was failing the system and called Respondent and told him the same thing. Respondent asked Mr. Rashley to come out to the site so they could both examine the system, and Mr. Rashley agreed. When they met at the site, Respondent asked Mr. Rashley to point out the three violations, which he did. Respondent's response was to tell him that he was sick and tired of college kids telling him how to install septic tank systems. Mr. Rashley said that he could not ignore violations of the rules. After Respondent became more upset, he moved to within inches of Mr. Rashley's face and asked him if he would approve the system. Mr. Rashley answered he would if Respondent fixed the violations. While Respondent yelled at Mr. Rashley only a few inches from his face, Mr. Rashley, feeling very uncomfortable, retreated to his vehicle and started to drive back to his office. Respondent got into his vehicle and tailgated Mr. Rashley the entire way. When they arrived at Mr. Rashley's office, Respondent told the secretary to call Mr. Rashley's boss. Claiming that Mr. Rashley had unfairly disapproved the system, Respondent asked Mr. Havig to visit the site himself. Mr. Havig agreed to do so. Mr. Havig visited the site on the morning of May 5 outside the presence of Respondent. He confirmed the violations. At their closest point, the drain lines were three feet four inches apart, and the septic tank lid was not sealed. Mr. Havig left a message for Respondent with this information. At Respondent's request, Mr. Havig agreed to meet Respondent at the site at 1:30 pm. Returning from lunch with two other men, Mr. Havig stopped off at the site to meet Respondent. He found that the header pipe violation had been corrected, but the other violations had not been. Mr. Havig and Respondent talked about the separation of the drain lines. Respondent said he could not move the pipe without disturbing the elevation, which is crucial to the functioning of the drainfield. Mr. Havig said he could either move the pipe or add another line so as to reduce the maximum separation between lateral lines to below 36 inches. Respondent complained that he could not maintain the position of the flexible pipe when pouring gravel over the pipes. Respondent became angry. He grabbed a section of the plastic pipe and said that he would show Mr. Havig. The gravel fell in behind the place where the pipe had rested. Respondent declared that he would get the homeowner's approval to cover up the system rather than modify it. Mr. Havig went to his car to get a camera, and Respondent began using a lot of vulgarity. As Mr. Havig took pictures of the installation, Respondent became angrier. His face turned red and he accused Mr. Rashley and Mr. Havig of harassing him. He warned Mr. Havig that, if they did not stop, they would have to suffer the repercussions. Moving very close to Mr. Havig and pounding his fist into his hand, Respondent asked Mr. Havig if he knew what Respondent meant. Mr. Havig said yes, that it was time for him to go. Respondent covered the system up shortly after Mr. Havig departed. Respondent did not allow a reinspection of the system to determine if he corrected either the separation of the drain lines, which he admits he did not correct, or if he sealed the septic tank lid, which he claims he did correct. Respondent has worked as a septic tank contractor in the area for 18 years. The likelihood of system failure is high if a septic tank lid is not properly sealed before the system is covered and placed into operation. Respondent appears to have been a responsible contractor. Based on these facts, there is enough doubt on the lid-sealing issue to preclude finding that Petitioner proved by clear and convincing evidence that Respondent did not seal the lid before covering the system. The pipes constituting the drain lines are manufactured to allow 18 inches of effluent to escape from either side of the pipe. By installing lines with more than 36 inches between each other or 18 inches between a line and a side, Respondent reduced the efficiency of the drainfield because parts of the drainfield, which lies beneath the lines, will not receive as much effluent as other parts of the drainfield. For awhile, due to safety concerns, Petitioner had to send two inspectors to inspect Respondent's work sites. Respondent never apologized to either Mr. Rashley or Mr. Havig until, acknowledging his unprofessional behavior, he apologized during the hearing. Respondent also noted that Petitioner has dealt with him professionally since the incidents in question. Petitioner and Respondent have had troubled dealings in the past. On one occasion, Petitioner insisted on the placement of a drainfield adjacent to an existing, failed drainfield, even though the existing and proposed drainfields drained directly into a canal. Respondent wanted to locate the drainfield well away from the canal. Unable to secure approval locally, Respondent took an appeal to Petitioner's representatives in Tallahassee, who approved Respondent's original, more sensible plan to relocate the drainfield. On the other hand, Respondent violated the minimum- separation rule for drain lines in 1993. Petitioner fined Respondent for the violation.
Recommendation It is RECOMMENDED that Petitioner enter a final order finding Respondent guilty of violating Rule 10D-6.056(4)(b) and thus 10D- 6.075(2)(a) by installing a drainfield with excessive separation between drain lines, Rule 10D-6.075(4)(d) by failing to call for a required inspection, and Rule 10D-6.075(4)(l)1 by engaging in gross misconduct in his behavior toward two of Petitioner's employees. It is further recommended that the final order impose an administrative fine against Respondent in the amount of $500. ENTERED on July 14, 1995, in Tallahassee, Florida. ROBERT E. MEALE Hearing Officer Division of Administrative Hearings The DeSoto Building 1230 Apalachee Parkway Tallahassee, Floirda 32399-1550 (904) 488-9675 Filed with the Clerk of the Division of Administrative Hearings on July 14, 1995. APPENDIX Rulings on Petitioner's Proposed Findings All adopted or adopted in substance except that Respondent failed to seal the septic tank lid, which is rejected as unsupported by the appropriate weight of the evidence. COPIES FURNISHED: Susan Mastin Scott Senior Health Attorney Department of Health and Rehabilitative Services P.O. Box 60085 Ft. Myers, FL 33906 Attorney Melanie A. McGahee 333 S. Commercio, Suite B Clewiston, FL 33440 Robert L. Powell Agency Clerk Department of Health and Rehabilitative Services 1323 Winewood Boulevard Tallahassee, FL 32399-0700 Martha Valiant, M. D. Director, Hendry County Public Health Unit P.O. Box 70 LaBelle, FL 33935
The Issue The issues to be resolved in this proceeding concerns whether the Respondent installed a septic system without a permit; whether a permit was required for the installation; whether the installation was of inadequate size; whether the Respondent caused the disconnection of an existing system without a permit, and whether that system was improperly abandoned. A related issue is whether the proposed $1,500.00 fine should be imposed if the violations are proven or what, if any, fine is warranted.
Findings Of Fact The Petitioner is an agency of the State of Florida charged, in pertinent part, by its organic statutes and rules, with regulating the practice of septic tank contracting and the installation and repair of septic tank and drainfield waste disposal systems and with licensure of such contractors pursuant to Rule Chapter 64E, Florida Administrative Code. The Respondent, Trammel Fowler (Fowler), is a licensed septic tank contractor regulated by the statutes and rules cited herein. Fowler has never been issued any citations or been subjected to discipline under the relevant statutes and rules enforced by the Petitioner with regard to septic system design, construction, installation and repair. He has worked in the septic tank installation business for 19 years. The Respondent installed a septic tank and drainfield system at 5642 Old Bethel Road, Crestview, Florida, a residential construction project (home) in 1993. The original septic tank system installed by the Respondent was finally approved on June 11, 1993. The home site at issue was originally designed to have the septic tank and drainfield system located in the backyard of the residence. Plumbing errors by the general contractor and the plumbing sub-contractor caused the plumbing system to be "stubbed-out" to the front of the house so that the septic tank and drainfield system was installed in the front of the house rather than in the backyard as originally designed and approved by the Petitioner. Additional excavation work was required at the site, which caused the soil type to change in the front of the house where the septic tank and drainfield were to be installed. This in turn required the Okaloosa County Health Department to require additional drainfield square footage to be added to the previously approved 600 square feet of drainfield, so that the drainfield installed in the front of the house by the Respondent ultimately encompassed 800 square feet. Thus, although the original site plans approved by the Okaloosa County Health Department were not followed, subsequent modifications to the system resulted in the septic tank system being fully approved by the Petitioner (through the Okaloosa County Health Department), on June 11, 1993. In the ensuing months, landscaping problems at the site caused surface water to collect around and above the drainfield area. This, coupled with a continuous water flow from the residence caused by leaking appliances, and particularly the commode, resulted in raw or partially treated wastewater becoming exposed on the surface of the ground, as a sanitary nuisance. This was caused as the septic tank and drainfield system became saturated by the excess water from the two referenced sources. This caused the failure of that septic tank and drainfield system within nine months of its original installation, as was noted on March 4, 1994, by the Department's representative Mr. Sims. It is undisputed that the Respondent, Mr. Fowler, did not cause or contribute to this septic tank system failure. He constructed the system as designed and approved by the Department (or as re- approved by the Department in June 1993 with the relocation of the system to the front yard of the residence and with the augmentation of the drainfield referenced above). The Department was aware of the failure of the original system in the front yard of the residence as early as March 1994. There is no evidence that an actual permit for repair of that system was ever issued. Mr. Fowler maintains that the Department had a policy at that time of authorizing repairs to systems that failed within one year of original installation, as this one did, without a written, formal permit process, but rather by informal approval and inspection of the repair work. The Petitioner disagrees and Mr. Sims, the Petitioner's representative, states that a permit was required, although no fee was charged. Indeed in 1994 a rule was enacted authorizing issuance of a permit for repair work for systems that failed within one year of original installation without being accompanied by the charging of a fee for that permit. In any event, prior to the rule change, repairs were authorized for failures within one year by the Department without a permit, but were required to be inspected and a notation made in the permit file or in some cases on a "nuisance complaint card," so authorization and inspection was supposed to be documented. When by the time the repair was effected by the installation of the backyard septic tank and drainfield system or "overflow-system" in February 1995, the rule change requiring issuance of a repair permit without fee had become effective. There is evidence that the Respondent was aware of this since, sometime in 1994, he had obtained a permit authorizing repair of a septic tank and drainfield site on "Windsor Circle" as shown by the Petitioner's Exhibits 6 and 7 in evidence. Be that as it may, the Respondent contends that Mr. Brown, the environmental specialist and inspector for the Department, met with him at the repair site in question and at least verbally authorized the repair of the system by installation of the septic tank and drainfield in the backyard of the residence; to be connected to the sewer line which also was connected with the malfunctioning system in the front yard of that residence. Mr. Brown in his testimony purports to have no memory of authorizing the repair work or inspecting it and seems confused as to whether he met with the Respondent at the site. The Petitioner acknowledges, as does Mr. Brown, that he has had problems since that time with memory lapses, attendant to two life-threatening injuries, which have apparently caused problems with memory loss. He purportedly suffers from post-traumatic stress syndrome and is taking medication with regard thereto. There is no dispute that he has problems with recall. Moreover, there is evidence that Mr. Brown met with the Respondent at an address on Old Bethel Road for some reason, as shown by a notation in Department records in February 1995. Consequently, while there is no doubt that the repair work in question was done without a written permit, there is evidence to corroborate Mr. Fowler's testimony to the effect that Mr. Brown inspected and reviewed the repair system while it was actually being installed by Fowler and approved it. Thus, it is possible that Mr. Fowler was under a good faith impression that the Department had a policy of inspecting and approving repair work without there being a permit related to it at the time when he installed the secondary "overflow" system at the Old Bethel Road site in February of 1995, even though that impression may have been legally mistaken, because the rule requiring a permit at no fee for repair work was already in effect. In any event, Mr. Fowler installed the so-called "repair system" in February 1995, which he has termed an "overflow" system designed to augment the treatment capability of the previously-approved system installed in the front yard at that residence. That system, as found above, consisted of 800 square feet of drainfield. The "overflow" system installed in the backyard by Mr. Fowler in February 1995 without the permit, has only 300 square feet of drainfield. This is clearly well below the minimum required for such a system and tends to support Mr. Fowler's testimony that it was intended really as a repair job in the form of a overflow system to handle extra flow that the original system in the front yard would not be able to handle in performing the intended treatment function. It is unlikely that Mr. Fowler, with or without a permit, would have installed a system he clearly would know to be of only one-half (or less) of the adequate size and treatment capability for the residence, if it had been intended to be a separately functioning independent treatment system for the residence. In fact, the "overflow" system was connected through a "T" or "Y" fitting in the sewer line outfall pipe from the house with the original septic tank and drainfield system in the front yard of the residence, so that flow could go to both systems simultaneously from the residential sewer line. There is conflicting testimony as to whether such a dually draining system could work properly. One septic tank contractor testified that it could and could adequately split the flow between the two septic tank and drainfield systems so as to perform adequate treatment without backups or overflows, while a witness for the Department testified that such a split-fitting could cause stoppages and therefore sewage backups. Be that as it may, the installation of the system in a connected fashion to the original system supports Mr. Fowler's testimony and contention that the system installed in the backyard, with 300 square feet of drainfield, was intended as a repair system merely to augment the treatment function being provided by the poorly functioning original system in the front yard. In fact, the preponderant evidence shows that, with the elimination of leakage from the appliances in the house and the correction of the water-pooling problem caused by improper landscaping, that the system would function adequately thus connected. Indeed, when the plumber or the general contractor for the residence disconnected the original front-yard septic tank system from the overflow system, so that all of the sewage in the house went to the overflow system with the smaller drainfield, that system still functioned adequately for one and one-half years until failure in approximately August 1997. It is undisputed that the Respondent had no part in the unreported and unapproved disconnection of the original front system from the overflow tank and drainfield system in the backyard. The evidence shows a preponderant likelihood that the total system would have functioned adequately indefinitely had the two remained connected so that sewage could flow to the front yard system with the 800 square feet of drainfield, with the excess water flow problems referenced above already corrected. Mr. Brown, the Department environmental specialist and inspector, did not recall specifically whether he had been at the Old Bethel Road site at issue, but testified that it was definitely possible. He testified that the time entry notation he made admitted into evidence as Exhibit No. 3, may have reflected an inspection for a repair job at the Old Bethel Road site. Mr. Brown admitted that he was present on Old Bethel Road in February 1995, but did not recall his purpose of being there. His testimony thus did not contradict the testimony of Trammel Fowler. Mr. Brown also testified that he was aware of problems at the Old Bethel Road site and testified that Mr. Wykle of the Department and Mr. Sims were also aware of problems at the Old Bethel Road site. Douglas Sims of the Department testified that the two systems, the original front tank and drainfield and the overflow tank and drainfield installed in the backyard by Mr. Fowler could not work together if they were connected. This is belied by testimony of a septic tank contractor, Ken Arnett, who was a rebuttal witness called by the Department. Mr. Arnett testified that he would expect a system of the type contemplated by Mr. Fowler and Mr. Brown to function properly. It thus seems from the preponderant weight of the evidence that the reason the Old Bethel Road residential system quit functioning properly, in approximately August 1997, is that the plumbing contractor, at the behest of the residential building contractor for the residence constructed there, disconnected the overflow system from the original front yard system, so that all the house effluent was going to the overflow system, which was never intended to have a complete, standard-sized drainfield for such a dwelling, prevalent soil conditions, elevations and the like. Mr. Brown, a long time employee of the Department was familiar with the statewide rules affecting septic tank contractors and installation and familiar with local department rules and policies relating to repairs. He testified that for a period of time in the early 1990's, there was an unwritten policy by the Okaloosa County Health Department that some repair permits would be waived for certain repairs provided a final inspection by the Department was made. He stated that if the septic tank system failed within one year under certain circumstances, a repair permit would be waived as long as the Department was aware of the repair. Mr. Brown could not recall when the policy ended, but estimated it to be sometime between 1995 and 1997. He called the discontinuation of the local policy to waive repair permits a "gradual phase out." Mr. Brown also recalled that the Okaloosa County Health Department's unwritten, local policy concerning waiver of repair permits was known and relied upon by septic tank contractors in certain situations. Cecil Rogers, a long-time septic tank contractor who dealt with the Okaloosa County Health Department regularly, testified that there was a standard policy to allow repairs to be made to septic tank systems that failed within one year without requiring a permit. There thus seems to have been an unwritten policy or practice among septic tank contractors and the Okaloosa County Health Department to the effect that if a system failed within one year and the contractor was willing to repair the system without cost to the homeowner, that the permit would be waived as long as the system or repair could be inspected by the Department. The system originally installed which failed appears to have been installed before the effective date of the rule requiring that a no-charge permit be obtained for repair work. The repair work in question, the installation of the overflow system, appears to have been effected after the effective date of the new rule. It also appears that Mr. Fowler knew of the new rule because of his obtaining a permit for repair work at the Windsor Circle repair site in 1994. It also would appear that Mr. Brown likely verbally approved and inspected the repair work at the subject site, giving Mr. Fowler the impression that he was authorized to go ahead and make the repair by installing the overflow system. Thus, although he may have technically violated the rule requiring a no-charge permit for repair work, it does not appear that he had any intent to circumvent the authority of the Department, since the preponderant evidence shows that Mr. Brown knew of and approved the installation. Thus, in this regard, a minimal penalty would be warranted. Moreover, after the original septic system at the Old Bethel Road site failed in March of 1994, through no fault of Fowler, Fowler paid to make the repair by installing the overflow system at his own expense. The original new home purchaser at that site, and Mr. Fowler's customer, Mr. Wayne Aaberg, thus did not sustain any personal expenses for the repair work performed by Fowler. The Petitioner did not present any evidence to establish that the repairs made by Fowler caused the septic tank system at Old Bethel Road to fail. The Petitioner, through the testimony of environmental manager Douglas Sims, itself established that the plumbing contractor actually disconnected the front system from the overflow system and made a physical connection only to the rear system installed by Mr. Fowler, rather than Fowler, and without Mr. Fowler's knowledge. The Petitioner, apparently through Douglas Sims, failed to conduct an investigation to determine which party actually was responsible for physically abandoning or disconnecting the original front system from the home and from the overflow system prior to the charges being filed against Mr. Fowler. Mr. Fowler did not cause the physical disconnection of the two systems and the residence and is not a licensed plumber. He did not, during the course of his contracting business for septic tanks and drainfields make physical connections or disconnections to dwelling units, but instead left that to the responsibility of the general contractor and/or the plumbing contractor. The Petitioner presented no evidence establishing any monetary harm to any customer of the Respondent. The disconnection of the systems which caused the failure was not shown to have been the responsibility nor fault of Mr. Fowler. Rather, any monetary harm to the homeowner who owned the residence when the failure occurred in August 1997, after the original repair installation had been paid for by Mr. Fowler was caused by the plumbing contractor and/or the general contractor, Kemp Brothers, who directed the plumbing contractor to disconnect the original front system from the overflow system. Consequently, any monetary damage caused by fixing the failure which occurred in August 1997, and which engendered the subject dispute, was not caused by Mr. Fowler. Finally, Mr. Douglas Sims of the Department, testified that he knew of two other un-permitted repairs by septic tank contractors which were known to the Department. In both of those cases, the contractors were only issued a Letter of Warning. Mr. Sims testified that if the Respondent herein had made repairs to the existing system at his own cost after the failure occurring in August of 1997, then the Department would have only issued a Letter of Warning. Mr. Fowler paid to fix the original system in February 1995, but felt that monetary responsibility for the August 1997 failure was not his fault and thus did not offer to pay for that.
Recommendation Accordingly, having considered the foregoing Findings of Fact, Conclusions of Law, the evidence of record, the candor and demeanor of the witnesses and the pleadings and arguments of the parties, it is, therefore, RECOMMENDED that a final order be entered finding that the Respondent effected repair work to a septic tank and drainfield system without the required written permit but that, in view of the above-found and concluded extenuating circumstances, that a minimal penalty of a letter of warning be issued to the Respondent by the Department and that the citation for violation, in all other respects, be dismissed. DONE AND ENTERED this 19th day of January, 2000, in Tallahassee, Leon County, Florida. P. MICHAEL RUFF Administrative Law Judge Division of Administrative Hearings The DeSoto Building 1230 Apalachee Parkway Tallahassee, Florida 32399-3060 (850) 488-9675 SUNCOM 278-9675 Fax Filing (850) 921-6847 www.doah.state.fl.us Filed with the Clerk of the Division of Administrative Hearings this 19th day of January, 2000. COPIES FURNISHED: Rodney M. Johnson, Esquire Department of Health Northwest Law Office 1295 West Fairfield Drive Pensacola, Florida 32501 Matthew D. Bordelon, Esquire 2721 Gulf Breeze Parkway Gulf Breeze, Florida 32561 Angela T. Hall, Agency Clerk Department of Health Bin A02 2020 Capital Circle, Southeast Tallahassee, Florida 32399-1703 Dr. Robert G. Brooks, Secretary Department of Health Bin A00 2020 Capital Circle, Southeast Tallahassee, Florida 32399-1701 Pete Peterson, General Counsel Department of Health Bin A02 2020 Capital Circle, Southeast Tallahassee, Florida 32399-1701